Comparison of 1.5-and 3.0-T MR Imaging for Evaluating the Articular Cartilage of the Knee Joint

被引:125
|
作者
Kijowski, Richard [1 ]
Blankenbaker, Donna G. [1 ]
Davis, Kirkland W. [1 ,2 ]
Shinki, Kazuhiko [1 ]
Kaplan, Lee D. [3 ]
De Smet, Arthur A. [1 ]
机构
[1] Univ Wisconsin Hosp, Dept Radiol, Madison, WI 53792 USA
[2] Univ Wisconsin Hosp, Dept Stat, Madison, WI 53792 USA
[3] Univ Wisconsin Hosp, Dept Orthoped Surg, Madison, WI 53792 USA
关键词
FAST-SPIN-ECHO; RISK-FACTORS; 1.5; T; ARTHROSCOPY; DEFECTS; LESIONS; OSTEOARTHRITIS; SEQUENCES; MODEL; RECONSTRUCTION;
D O I
10.1148/radiol.2503080822
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To retrospectively compare the diagnostic performance of 1.5- and 3.0-T magnetic resonance (MR) imaging protocols for evaluating the articular cartilage of the knee joint in symptomatic patients. Materials and Methods: This HIPAA-compliant study was performed with a waiver of informed consent from the institutional review board. The study group consisted of 200 symptomatic patients undergoing MR examination of the knee at 1.5 T (61 men, 39 women; mean age, 38.9 years) or 3.0 T (52 men, 48 women; mean age, 39.1 years), who also underwent subsequent arthroscopic knee surgery. All MR examinations consisted of multiplanar fast spin-echo sequences with similar tissue contrast at 1.5 and 3.0 T. All articular surfaces were graded at arthroscopy by using the Noyes classification system. Three musculoskeletal radiologists retrospectively and independently graded all articular surfaces seen at MR imaging by using a similar classification system. The sensitivity, specificity, and accuracy of the 1.5- and 3.0-T MR protocols for detecting cartilage lesions were determined by using arthroscopy as the reference standard. The z test was used to compare sensitivity, specificity, and accuracy values at 1.5 and 3.0 T. Results: For all readers combined, the respective sensitivity, specificity, and accuracy of MR imaging for detecting cartilage lesions were 69.3%, 78.0%, and 74.5% at 1.5 T (n = 241) and 70.5%, 85.9%, and 80.1% at 3.0 T (n = 226). The MR imaging protocol had significantly higher specificity and accuracy (P < .05) but not higher sensitivity (P = .73) for detecting cartilage lesions at 3.0 T than at 1.5 T. Conclusion: A 3.0-T MR protocol has improved diagnostic performance for evaluating the articular cartilage of the knee joint in symptomatic patients when compared with a 1.5- T protocol. (c) RSNA, 2009
引用
收藏
页码:839 / 848
页数:10
相关论文
共 50 条
  • [41] Comparison of 3.0-T MR vs 3.0-T MR arthrography of the hip for detection of acetabular labral tears and chondral defects in the same patient population
    Magee, T.
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1053):
  • [42] Thirty Minutes of Running Exercise Decreases T2 Signal Intensity but Not Thickness of the Knee Joint Cartilage: A 3.0-T Magnetic Resonance Imaging Study
    Karanfil, Yigitcan
    Babayeva, Naila
    Donmez, Giirhan
    Diren, H. Baris
    Eryilmaz, Muzaffer
    Doral, Mahmut Nedim
    Korkusuz, Feza
    CARTILAGE, 2019, 10 (04) : 444 - 450
  • [43] Morphological MR imaging of the articular cartilage of the knee at 3 T—comparison of standard and novel 3D sequences
    Van Dyck P.
    Vanhevel F.
    Vanhoenacker F.M.
    Wouters K.
    Grodzki D.M.
    Gielen J.L.
    Parizel P.M.
    Insights into Imaging, 2015, 6 (3) : 285 - 293
  • [44] Evaluation of the Articular Cartilage of the Knee Joint: Value of Adding a T2 Mapping Sequence to a Routine MR Imaging Protocol
    Kijowski, Richard
    Blankenbaker, Donna G.
    del Rio, Alejandro Munoz
    Baer, Geoffrey S.
    Graf, Ben K.
    RADIOLOGY, 2013, 267 (02) : 503 - 513
  • [45] Application of a flexible loop-gap resonator for MR imaging of articular cartilage at 3.0T
    Tsai, JC
    Ashjaee, S
    Adalsteinsson, E
    Brosnan, TJ
    Lang, PK
    Hargreaves, BA
    RADIOLOGY, 2000, 214 (02) : 609 - 609
  • [46] Abdominopelvic 1.5-T and 3.0-T MR Imaging in Healthy Volunteers: Relationship to Formation of DNA Double-Strand Breaks
    Suntharalingam, Saravanabavaan
    Mladenov, Emil
    Sarabhai, Theresia
    Wetter, Axel
    Kraff, Oliver
    Quick, Harald H.
    Forsting, Michael
    Iliakis, Georg
    Nassenstein, Kai
    RADIOLOGY, 2018, 288 (02) : 529 - 535
  • [47] Quantitative Magnetic Resonance Imaging of the Articular Cartilage of the knee Joint
    Kijowski, Richard
    Chaudhary, Rajeev
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2014, 22 (04) : 649 - +
  • [48] Detection of hepatic metastases by superparamagnetic iron oxide-enhanced MR imaging: prospective comparison between 1.5-T and 3.0-T images in the same patients
    Keitaro Sofue
    Masakatsu Tsurusaki
    Mototaka Miyake
    Aine Sakurada
    Yasuaki Arai
    Kazuro Sugimura
    European Radiology, 2010, 20 : 2265 - 2273
  • [49] Comparison of 1.5-T 3D SPACE MR Imaging of the Knee vs Conventional MR Imaging of the Knee
    Magee, T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [50] Comparative study of imaging at 3.0 T versus 1.5 T of the knee
    Wong, Scott
    Steinbach, Lynne
    Zhao, Jian
    Stehling, Christoph
    Ma, C. Benjamin
    Link, Thomas M.
    SKELETAL RADIOLOGY, 2009, 38 (08) : 761 - 769