Comparison of 1.5-and 3.0-T MR Imaging for Evaluating the Articular Cartilage of the Knee Joint

被引:125
|
作者
Kijowski, Richard [1 ]
Blankenbaker, Donna G. [1 ]
Davis, Kirkland W. [1 ,2 ]
Shinki, Kazuhiko [1 ]
Kaplan, Lee D. [3 ]
De Smet, Arthur A. [1 ]
机构
[1] Univ Wisconsin Hosp, Dept Radiol, Madison, WI 53792 USA
[2] Univ Wisconsin Hosp, Dept Stat, Madison, WI 53792 USA
[3] Univ Wisconsin Hosp, Dept Orthoped Surg, Madison, WI 53792 USA
关键词
FAST-SPIN-ECHO; RISK-FACTORS; 1.5; T; ARTHROSCOPY; DEFECTS; LESIONS; OSTEOARTHRITIS; SEQUENCES; MODEL; RECONSTRUCTION;
D O I
10.1148/radiol.2503080822
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To retrospectively compare the diagnostic performance of 1.5- and 3.0-T magnetic resonance (MR) imaging protocols for evaluating the articular cartilage of the knee joint in symptomatic patients. Materials and Methods: This HIPAA-compliant study was performed with a waiver of informed consent from the institutional review board. The study group consisted of 200 symptomatic patients undergoing MR examination of the knee at 1.5 T (61 men, 39 women; mean age, 38.9 years) or 3.0 T (52 men, 48 women; mean age, 39.1 years), who also underwent subsequent arthroscopic knee surgery. All MR examinations consisted of multiplanar fast spin-echo sequences with similar tissue contrast at 1.5 and 3.0 T. All articular surfaces were graded at arthroscopy by using the Noyes classification system. Three musculoskeletal radiologists retrospectively and independently graded all articular surfaces seen at MR imaging by using a similar classification system. The sensitivity, specificity, and accuracy of the 1.5- and 3.0-T MR protocols for detecting cartilage lesions were determined by using arthroscopy as the reference standard. The z test was used to compare sensitivity, specificity, and accuracy values at 1.5 and 3.0 T. Results: For all readers combined, the respective sensitivity, specificity, and accuracy of MR imaging for detecting cartilage lesions were 69.3%, 78.0%, and 74.5% at 1.5 T (n = 241) and 70.5%, 85.9%, and 80.1% at 3.0 T (n = 226). The MR imaging protocol had significantly higher specificity and accuracy (P < .05) but not higher sensitivity (P = .73) for detecting cartilage lesions at 3.0 T than at 1.5 T. Conclusion: A 3.0-T MR protocol has improved diagnostic performance for evaluating the articular cartilage of the knee joint in symptomatic patients when compared with a 1.5- T protocol. (c) RSNA, 2009
引用
收藏
页码:839 / 848
页数:10
相关论文
共 50 条
  • [31] MR Imaging of Endometrial Carcinoma for Preoperative Staging at 3.0 T: Comparison With Imaging at 1.5 T
    Hori, Masatoshi
    Kim, Tonsok
    Murakami, Takamichi
    Imaoka, Izumi
    Onishi, Hiromitsu
    Nakamoto, Atsushi
    Nakaya, Yasuhiro
    Tomoda, Kaname
    Tsutsui, Tateki
    Enomoto, Takayuki
    Kimura, Tadashi
    Nakamura, Hironobu
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (03) : 621 - 630
  • [32] Chondrocalcinosis of the articular cartilage of the knee: MR imaging manifestations
    Beltran, J
    MartyDelfaut, E
    Bencardino, J
    Rosenberg, ZS
    Steiner, GC
    Aparisi, F
    RADIOLOGY, 1997, 205 : 1162 - 1162
  • [33] 3.0-T Evaluation of Knee Cartilage by Using Three-Dimensional IDEAL GRASS Imaging: Comparison with Fast Spin-Echo Imaging
    Kijowski, Richard
    Blankenbaker, Donna G.
    Woods, Michael A.
    Shinki, Kazuhiko
    De Smet, Arthur A.
    Reeder, Scott B.
    RADIOLOGY, 2010, 255 (01) : 117 - 127
  • [34] Heating of Hip Arthroplasty Implants During Metal Artifact Reduction MRI at 1.5-and 3.0-T Field Strengths
    Khodarahmi, Iman
    Rajan, Sunder
    Sterling, Robert
    Koch, Kevin
    Kirsch, John
    Fritz, Jan
    INVESTIGATIVE RADIOLOGY, 2021, 56 (04) : 232 - 243
  • [35] Intraindividual comparison of MR-renal perfusion imaging at 1.5 T and 3.0 T
    Michaely, Henrik J.
    Kramer, Harald
    Oesingmann, Niels
    Lodemann, Klaus-Peter
    Miserock, Karl
    Reiser, Maximilian F.
    Schoenberg, Stefan O.
    INVESTIGATIVE RADIOLOGY, 2007, 42 (06) : 406 - 411
  • [36] Detection of Compression Vessels in Trigeminal Neuralgia by Surface-Rendering Three-Dimensional Reconstruction of 1.5-and 3.0-T Magnetic Resonance Imaging
    Shimizu, Masahiro
    Imai, Hideaki
    Kagoshima, Kaiei
    Umezawa, Eriko
    Shimizu, Tsuneo
    Yoshimoto, Yuhei
    WORLD NEUROSURGERY, 2013, 80 (3-4) : 378 - 385
  • [37] Rapid multicomponent T2 analysis of the articular cartilage of the human knee joint at 3.0T
    Liu, Fang
    Chaudhary, Rajeev
    Hurley, Samuel A.
    del Rio, Alejandro Munoz
    Alexander, Andrew L.
    Samsonov, Alexey
    Block, Walter F.
    Kijowski, Richard
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (05) : 1191 - 1197
  • [38] 1.5 MRT OF THE HYALINE ARTICULAR-CARTILAGE OF THE KNEE-JOINT
    ADAM, G
    BOHNDORF, K
    PRESCHER, A
    KRASNY, R
    GUNTHER, RW
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1988, 148 (06): : 648 - 651
  • [39] An Application of Algebraic Method on MR T2 Imaging of Knee Articular Cartilage
    Dai, Xu
    Sharma, Gulshan B.
    Kuntze, Gregor
    Kuepper, Jessica
    Frayne, Richard
    Ronsky, Janet
    2013 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST 2013), 2013, : 174 - 177
  • [40] Articular cartilage MR imaging and thickness mapping of a loaded knee joint before and after meniscectomy
    Song, Y.
    Greve, J. M.
    Carter, D. R.
    Koo, S.
    Giori, N. J.
    OSTEOARTHRITIS AND CARTILAGE, 2006, 14 (08) : 728 - 737