Seismic performance assessment of conventional CLT shear wall structures and post-tensioned CLT shear wall structures

被引:48
作者
Sun, Xiaofeng [1 ,2 ]
He, Minjuan [1 ]
Li, Zheng [1 ]
Lam, Frank [2 ]
机构
[1] Tongji Univ, Dept Struct Engn, Shanghai 200092, Peoples R China
[2] Univ British Columbia, Dept Wood Sci, Vancouver, BC V6T 1Z4, Canada
基金
中国国家自然科学基金;
关键词
Cross-laminated timber; Direct displacement-based design method; Seismic performance; Conventional CLT shear wall structures; Post-tensioned CLT shear wall structures; LAMINATED TIMBER STRUCTURES; BEHAVIOR; TESTS;
D O I
10.1016/j.engstruct.2019.109285
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents the performance-based seismic assessment framework on conventional CLT shear wall structures (C-CLTStrs) and post-tensioned CLT shear wall structures (PT-CLTStrs). Numerical models of both the conventional CLT shear walls and the PT CLT shear walls were developed and calibrated with experimental results. A direct displacement-based design (DDD) procedure was then developed and demonstrated by the design examples of one 8-storey C-CLTStr and a set of 8-, 12-, and 16-storey PT-CLTStrs. Corresponding simplified structural models were developed. A series of pushover and time-history dynamic analysis was conducted afterwards to calibrate the calculated structural performance objectives with the design targets of the DDD procedure. Finally, using 50 mainshock (MS) and 50 mainshock-aftershock (MSAS) earthquake records, probability seismic demanding analysis (PSDA) were conducted to evaluate two engineering demanding parameters of the structures, namely the maximum inter-storey drift (MaxISDR) and the residual inter-storey drift (ResISDR). The MaxISDR limit states of the PT-CLTStrs are recommended at 0.7%, 1.4%, and 2.2% for the immediate occupancy (IO), life safety (LS), and collapse prevention (CP) hazard levels, respectively. The MaxISDR of the PT-CLTStrs is almost twice that of the C-CLTStrs, while the ResISDR is at most 50% of that of the C-CLTStrs. The damage probability of the 8-storey PT-CLTStr indicated by ResISDR is not significantly sensitive to the consideration of aftershocks seismic input, whereas, when aftershocks are considered, up to a 7.0% difference under the LS hazard level is caused in the damage probability of the 8-storey C-CLTStr indicated by ResISDR.
引用
收藏
页数:17
相关论文
共 50 条
[41]   Experimental study on the performance of damaged precast shear wall structures after base isolation [J].
Zhang, Ruijun ;
Li, Aiqun .
ENGINEERING STRUCTURES, 2021, 228
[42]   Assessment of the shear strength of an existing post-tensioned concrete bridge with a low amount of shear reinforcement - First application of the "Flexural Shear Crack" model in practice [J].
Huber, Patrick ;
Kratzer, Kurt ;
Huber, Tobias ;
Kleiser, Michael ;
Kollegger, Johann .
BETON- UND STAHLBETONBAU, 2016, 111 (11) :706-715
[43]   Seismic performance of CLT shear walls anchored with energy-dissipation connections: Experimental investigation and parametric analysis [J].
Chen, Jiawei ;
He, Zhen ;
Wei, Yang ;
Wang, Ruiming ;
Furuta, Tomoki ;
Xiong, Haibei .
ENGINEERING STRUCTURES, 2025, 331
[44]   Seismic performance of ductile shear wall frame systems [J].
Neagu, C. ;
Dubina, D. ;
Dinu, F. .
SSE '09: PROCEEDINGS OF THE 11TH WSEAS INTERNATIONAL CONFERENCE ON SUSTAINABILITY IN SCIENCE ENGINEERING, 2009, :395-+
[45]   Effects of unbonded steel layout on seismic behavior of post-tensioned precast concrete shear walls [J].
Erkmen, Bulent .
BULLETIN OF EARTHQUAKE ENGINEERING, 2021, 19 (01) :179-201
[46]   Comparative study on the seismic performance of two types of quay wall structures [J].
Ye, Bin ;
Ye, Guanlin ;
Lu, Jiafeng .
MARINE GEORESOURCES & GEOTECHNOLOGY, 2017, 35 (05) :621-630
[47]   Seismic performance quantification of buckling-restrained steel plate shear wall-RC frame structures [J].
Jin, Shuangshuang ;
Xie, Yu ;
Li, Mengyi ;
Bai, Jiulin .
JOURNAL OF BUILDING ENGINEERING, 2022, 58
[48]   Seismic Performance Assessment of Bolt Connection-based Assembled Composite Shear-wall [J].
Wang, Yi ;
Wang, Zhaochen ;
You, Peibo ;
Zhao, Jin ;
Hao, Xuedong .
IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF CIVIL ENGINEERING, 2022, 46 (05) :3723-3737
[49]   Seismic Performance of Shear Wall with CFST Columns and Encased Steel Truss [J].
Yang, Yabin ;
Cao, Wanlin .
JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2016, 15 (03) :613-618
[50]   Shear performance of vertical joints with different lapping splices for precast concrete frame-shear wall structures [J].
Li, Yongquan ;
Tong, Jiaxin ;
Yang, Yuanzhang ;
Sun, Bochao ;
Zhao, Weijian .
STRUCTURAL CONCRETE, 2022, 23 (03) :1572-1592