Gas Chromatography Coupled to Atmospheric Pressure Chemical Ionization FT-ICR Mass Spectrometry for Improvement of Data Reliability

被引:23
|
作者
Schwemer, Theo [1 ,2 ]
Rueger, Christopher P. [1 ]
Sklorz, Martin [1 ,3 ]
Zimmermann, Ralf [1 ,2 ,3 ]
机构
[1] Univ Rostock, Chair Analyt Chem, Joint Mass Spectrometry Ctr, D-18051 Rostock, Germany
[2] HICE Helmholtz Virtual Inst Complex Mol Syst Envi, D-85764 Neuherberg, Germany
[3] Helmholtz Zentrum Munchen, Cooperat Grp Comprehens Mol Analyt, Joint Mass Spectrometry Ctr, D-85764 Neuherberg, Germany
关键词
MS; PETROLEOMICS;
D O I
10.1021/acs.analchem.5b02114
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Atmospheric pressure chemical ionization (APCI) offers the advantage of molecular ion information with low fragmentation. Hyphenating APCI to gas chromatography (GC) and ultrahigh resolution mass spectrometry (FT-ICR MS) enables an improved characterization of complex mixtures. Data amounts acquired by this system are very huge, and existing peak picking algorithms are usually extremely time-consuming, if both gas chromatographic and ultrahigh resolution mass spectrometric data are concerned. Therefore, automatic routines are developed that are capable of handling these data sets and further allow the identification and removal of known ionization artifacts (e.g., water- and oxygen-adducts, demethylation, dehydrogenation, and decarboxylation). Furthermore, the data quality is enhanced by the prediction of an estimated retention index, which is calculated simply from exact mass data combined with a double bond equivalent correction. This retention index is used to identify mismatched elemental compositions. The approach was successfully tested for analysis of semivolatile components in heavy fuel oil and diesel fuel as well as primary combustion particles emitted by a ship diesel research engine. As a result, 10-28% of the detected compounds, mainly low abundant species, classically assigned by using only the mass spectrometric information, were identified as not valid and removed. Although GC separation is limited by the slow acquisition rate of the FT-ICR MS (<1 Hz), a database driven retention time comparison, as commonly used for low resolution GC/MS, can be applied for revealing isomeric information.
引用
收藏
页码:11957 / 11961
页数:5
相关论文
共 50 条
  • [31] GAS CHROMATOGRAPHY - CHEMICAL IONIZATION MASS SPECTROMETRY
    ARSENAUL.GP
    DOLHUN, JJ
    BIEMANN, K
    JOURNAL OF THE CHEMICAL SOCIETY D-CHEMICAL COMMUNICATIONS, 1970, (22): : 1542 - &
  • [32] Analysis of brominated flame retardants and their derivatives by atmospheric pressure chemical ionization using gas chromatography coupled to tandem quadrupole mass spectrometry
    Geng, Dawei
    Kukucka, Petr
    Jogsten, Ingrid Ericson
    TALANTA, 2017, 162 : 618 - 624
  • [33] Evaluation of gas chromatography-atmospheric pressure chemical ionization-mass spectrometry as an alternative to gas chromatography-electron ionization-mass spectrometry: Avocado fruit as example
    Hurtado-Fernandez, Elena
    Pacchiarotta, Tiziana
    Longueira-Suarez, Enrique
    Mayboroda, Oleg A.
    Fernandez-Gutierrez, Alberto
    Carrasco-Pancorbo, Alegria
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1313 : 228 - 244
  • [34] Matrix-assisted laser desorption/ionization (MALDI) FT-ICR mass spectrometry of oligosaccharides.
    Solouki, T
    Reinhold, BB
    Costello, CE
    OMalley, M
    Guan, SH
    Marshall, AG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1996, 212 : 21 - BIOL
  • [35] Matrix-assisted laser desorption/ionization (MALDI) FT-ICR mass spectrometry of oligosaccharides.
    Solouki, T
    Reinhold, BB
    Costello, CE
    OMalley, M
    Guan, SH
    Marshall, AG
    BIOCHEMISTRY, 1996, 35 (28) : 21 - 21
  • [36] Molecular transformation of dissolved organic matter in refinery wastewaters: Characterized by FT-ICR MS coupled with electrospray ionization and atmospheric pressure photoionization
    He, Chen
    Chen, Wei-Ming
    Chen, Chun-Mao
    Shi, Quan
    PETROLEUM SCIENCE, 2023, 20 (01) : 590 - 599
  • [37] Molecular transformation of dissolved organic matter in refinery wastewaters: Characterized by FT-ICR MS coupled with electrospray ionization and atmospheric pressure photoionization
    Chen He
    WeiMing Chen
    ChunMao Chen
    Quan Shi
    Petroleum Science, 2023, 20 (01) : 590 - 599
  • [38] Atmospheric pressure chemical ionization of fluorinated phenols in atmospheric pressure chemical ionization mass spectrometry, tandem mass spectrometry, and ion mobility spectrometry
    Eiceman, GA
    Bergloff, JF
    Rodriguez, JE
    Munro, W
    Karpas, Z
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (11) : 1157 - 1165
  • [39] Laserspray and Matrix-Assisted Ionization Inlet Coupled to High-Field FT-ICR Mass Spectrometry for Peptide and Protein Analysis
    Nyadong, Leonard
    Inutan, Ellen D.
    Wang, Xu
    Hendrickson, Christopher L.
    Trimpin, Sarah
    Marshall, Alan G.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (03) : 320 - 328
  • [40] How Well Do We Handle the Sample Preparation, FT-ICR Mass Spectrometry Analysis, and Data Treatment of Atmospheric Waters?
    Pailler, Lucas
    Renard, Pascal
    Nicol, Edith
    Deguillaume, Laurent
    Bianco, Angelica
    MOLECULES, 2022, 27 (22):