Impact of Different Visual Field Instruction Strategies on Reliability Indices

被引:3
|
作者
Rao, Aparna [1 ]
Sarangi, Sarada Prasanna [1 ]
Padhy, Debananda [1 ]
Raj, Niranjan [1 ]
Das, Gopinath [1 ]
机构
[1] LV Prasad Eye Inst, Glaucoma Serv, Bhubaneswar, Orissa, India
关键词
Glaucoma; Humphrey field analyzer; reliability indices; visual field; AUTOMATED PERIMETRY; RESPONSE PROPERTIES; GLAUCOMA; EXPERIENCE; THRESHOLD; CRITERION;
D O I
10.1080/08820538.2017.1416413
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate and compare the visual field performance following three different types of visual field instruction strategies. Method: Ninety consecutive visual field-naive glaucoma patients who can perform the test and understand instructions were imparted three forms of instructions prior to the visual field test. Patients with visual acuity <20/200, central corneal opacities, or anterior segment pathology and patients unable to understand general instructions/uncooperative were excluded. All forms of instructions were given by a trained optometrist in the patients' own language as an instruction leaflet read out in 5 min for a verbal group (groupl) and by a 5 min video created in house (group 2). Group 3 patients were shown the video first, followed by verbal instructions. We evaluated the reliability parameters in each group after visual field testing by an independent optometrist blinded to the form of instruction given. Results: Among the three groups, group 3 patients had the least number of repeat tests. Eyes with MD<-12Db had better reliability than that of the other groups. Mixed-model linear regression analysis shows that the duration of the test was significantly influenced by the severity of glaucoma in group 1, which is further predisposed by false negatives (FN; beta = 0.06, p < 0.0001, R-2 61.7%). Conclusion: The video with verbal instruction can minimize the number of repeated tests compared with only verbal or only video instruction medium. The video as well as the combined video/verbal instructions have a practical influence of obtaining more reliable fields compared with only verbal instruction.
引用
收藏
页码:683 / 689
页数:7
相关论文
共 50 条
  • [1] The Association Between Visual Field Reliability Indices and Cognitive Impairment in Glaucoma Patients
    Raman, Pushpa
    Ching, Yeap Khy
    Sivagurunathan, Premala D.
    Ramli, Norlina
    Khalia, Khairul H. Mohd
    JOURNAL OF GLAUCOMA, 2019, 28 (08) : 685 - 690
  • [2] Real-World Analysis of the Aging Effects on Visual Field Reliability Indices in Humans
    Shirakami, Tomoki
    Omura, Tetsuro
    Fukuda, Hiroki
    Asaoka, Ryo
    Tanito, Masaki
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (24)
  • [3] Reliability of Simultaneous Visual Field Testing
    Kramer, Benjamin C.
    Musch, David C.
    Niziol, Leslie M.
    Weizer, Jennifer S.
    OPHTHALMOLOGY, 2012, 119 (02) : 304 - 307
  • [4] The association between ocular surface measurements with visual field reliability indices and gaze tracking results in preperimetric glaucoma
    Arai, Takahiro
    Murata, Hiroshi
    Matsuura, Masato
    Usui, Tomohiko
    Asaoka, Ryo
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (04) : 525 - 530
  • [5] Real-World Analysis of the Aging Effects on Visual Field Reliability Indices in Central 10-2 Tests
    Shirakami, Tomoki
    Omura, Tetsuro
    Fukuda, Hiroki
    Asaoka, Ryo
    Tanito, Masaki
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (10):
  • [6] Roles of Cognitive Function on Visual Field Reliability Indices among Glaucoma Patients
    Ichitani, Aona
    Takao, Eri
    Tanito, Masaki
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (22)
  • [7] Role of Visual Field Reliability Indices in Ruling Out Glaucoma
    Rao, Harsha L.
    Yadav, Ravi K.
    Begum, Viquar U.
    Addepalli, Uday K.
    Choudhari, Nikhil S.
    Senthil, Sirisha
    Garudadri, Chandra S.
    JAMA OPHTHALMOLOGY, 2015, 133 (01) : 40 - 44
  • [8] The Usefulness of Gaze Tracking as an Index of Visual Field Reliability in Glaucoma Patients
    Ishiyama, Yukako
    Murata, Hiroshi
    Asaoka, Ryo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (11) : 6233 - 6236
  • [9] Optic disc surface smoothness and visual field indices
    Maurizio Rolando
    A. Macrì
    Michele Iester
    Graefe's Archive for Clinical and Experimental Ophthalmology, 1999, 237 : 372 - 376
  • [10] The Frontloading Fields Study: The Impact of False Positives and Seeding Point Errors on Visual Field Reliability When Using SITA-Faster
    Phu, Jack
    Kalloniatis, Michael
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (02):