Rapid amplification of genetically modified organisms using a circular ferrofluid-driven PCR microchip

被引:23
作者
Sun, Yi [1 ]
Kwok, Yien-Chian [1 ]
Lee, Peter Foo-Peng [1 ]
Nguyen, Nam-Trung [2 ]
机构
[1] Nanyang Technol Univ, Natl Inst Educ, Singapore 637616, Singapore
[2] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
关键词
Genetic modified organism (GMO); Ferrofluid; PCR microchip; PMMA; POLYMERASE-CHAIN-REACTION; MICROFLUIDIC DEVICES; DNA AMPLIFICATION; MODIFIED SOYBEANS; MAIZE;
D O I
10.1007/s00216-009-2808-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of genetically modified organisms (GMOs) as food and in food products is becoming more and more widespread. Polymerase chain reaction (PCR) technology is extensively used for the detection of GMOs in food products in order to verify compliance with labeling requirements. In this paper, we present a novel close-loop ferrofluid-driven PCR microchip for rapid amplification of GMOs. The microchip was fabricated in polymethyl methacrylate by CO2 laser ablation and was integrated with three temperature zones. PCR solution was contained in a circular closed microchannel and was driven by magnetic force generated by an external magnet through a small oil-based ferrofluid plug. Successful amplification of genetically modified soya and maize were achieved in less than 13 min. This PCR microchip combines advantages of cycling flexibility and quick temperature transitions associated with two existing microchip PCR techniques, and it provides a cost saving and less time-consuming way to conduct preliminary screening of GMOs.
引用
收藏
页码:1505 / 1508
页数:4
相关论文
共 15 条
  • [1] Comparison of simplex and duplex real-time PCR for the quantification of GMO in maize and soybean
    Alary, R
    Serin, A
    Maury, D
    Ben Jouira, H
    Sirven, JP
    Gautier, MF
    Joudrier, P
    [J]. FOOD CONTROL, 2002, 13 (4-5) : 235 - 244
  • [2] A reusable flow-through polymerase chain reaction instrument for the continuous monitoring of infectious biological agents
    Belgrader, P
    Elkin, CJ
    Brown, SB
    Nasarabadi, SN
    Langlois, RG
    Milanovich, FP
    Colston, BW
    Marshall, GD
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (14) : 3446 - 3450
  • [3] A miniaturized cyclic PCR device - modeling and experiments
    Chou, CF
    Changrani, R
    Roberts, P
    Sadler, D
    Burdon, J
    Zenhausern, F
    Lin, S
    Mulholland, A
    Swami, N
    Terbrueggen, R
    [J]. MICROELECTRONIC ENGINEERING, 2002, 61-2 : 921 - 925
  • [4] A Microfabricated Rotary Pump
    Chou, Hou-Pu
    Unger, Marc A.
    Quake, Stephen R.
    [J]. BIOMEDICAL MICRODEVICES, 2001, 3 (04) : 323 - 330
  • [5] Continuous segmented-flow polymerase chain reaction for high-throughput miniaturized DNA amplification
    Curcio, M
    Roeraade, J
    [J]. ANALYTICAL CHEMISTRY, 2003, 75 (01) : 1 - 7
  • [6] A general multiplex-PCR assay for the general detection of genetically modified soya and maize
    Forte, VT
    Di Pinto, A
    Martino, C
    Tantillo, GM
    Grasso, G
    Schena, FP
    [J]. FOOD CONTROL, 2005, 16 (06) : 535 - 539
  • [7] The official method for the detection of genetically modified soybeans (German Food Act LMBG 35): a semi-quantitative study of sensitivity limits with glyphosate-tolerant soybeans (Roundup Ready) and insect-resistant Bt maize (Maximizer)
    Jankiewicz, A
    Broll, H
    Zagon, J
    [J]. EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 1999, 209 (02) : 77 - 82
  • [8] Bulk-micromachined submicroliter-volume PCR chip with very rapid thermal response and low power consumption
    Lee, DS
    Park, SH
    Yang, HS
    Chung, KH
    Yoon, TH
    Kim, SJ
    Kim, K
    Kim, YT
    [J]. LAB ON A CHIP, 2004, 4 (04) : 401 - 407
  • [9] Lin HY, 2000, J FOOD DRUG ANAL, V8, P200
  • [10] Nguyen N.-T., 2019, Fundamentals and Applications of Micro fluidics