CASA: a Readout ASIC for Gas Detectors with Self-Amplification

被引:0
|
作者
Deng, Zhi [1 ]
Liu, Yinong [1 ]
Li, Yancun [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
来源
2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9 | 2009年
关键词
GEM;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A readout ASIC has been designed for gas detectors with self-amplification such as GEM and RPC. It provides amplification and CR-(RC)(4) shaping of the detector signals and buffers them to the free running ADCs at similar to 10MSPS. The charge gain can be adjusted from 1mV/fC to 28mV/fC and the shaping time can be adjusted from 25ns to 100ns. The programmability of the gain in such wide range and the shaping time is very convenient for studying detector performance and also expands the application range of the chip. The ENC increases as charge gain decreases below 10mV/fC because the noise from the shaper becomes significant. The chip is designed in Chartered 0.35 mu m 2P4M CMOS process. Detailed circuit description and preliminary test results will be shown below.
引用
收藏
页码:1304 / 1306
页数:3
相关论文
共 7 条
  • [1] Gaseous detectors with micropattern gas amplification stages and CMOS pixel chip readout
    Kaminski, J.
    Brezina, C.
    Desch, K.
    Killenberg, M.
    Krautscheid, T.
    Krieger, C.
    Mueller, F.
    Schultens, M.
    JOURNAL OF INSTRUMENTATION, 2012, 7
  • [2] A mixed-signal ASIC for the readout of Gas Electron Multiplier detectors Design review and characterization results
    Cossio, Fabio
    2017 13TH CONFERENCE ON PH.D. RESEARCH IN MICROELECTRONICS AND ELECTRONICS (PRIME), 2017, : 33 - 36
  • [3] CASCADE, neutron detectors for highest count rates in combination with ASIC/FPGA based readout electronics
    Klein, Martin
    Schmidt, Christian J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 628 (01): : 9 - 18
  • [4] A novel method of encoded multiplexing readout for micro-pattern gas detectors
    Qi, Bin-Xiang
    Liu, Shu-Bin
    Ji, Heng
    Shen, Zhong-Tao
    Ma, Si-Yuan
    Liu, Hong-Bang
    Huang, Wen-Qian
    An, Qi
    CHINESE PHYSICS C, 2016, 40 (05)
  • [5] GEMINI, a CMOS 180 nm Mixed-Signal 16-Channel ASIC for Triple-GEM Detectors Readout
    Pezzotta, A.
    Corradi, G.
    Croci, G.
    De Matteis, M.
    Murtas, F.
    Tagnani, D.
    Gorini, G.
    Baschirotto, A.
    2015 IEEE SENSORS, 2015, : 1134 - 1137
  • [6] Development of high resolution Micro-Pattern Gas Detectors with wide readout pads
    Dixit, M.
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [7] A Segmental 2D Readout Board Manufactured in Printed Circuit Board Technology for Gas Electron Multiplier Detectors
    Babij, Michal
    Bielowka, Piotr
    Gburek, Szymon
    Malecha, Karol
    SENSORS, 2023, 23 (19)