Effect of the source and detector configuration on the detectability of breast cancer

被引:7
作者
Honar, AL
Kang, KA [1 ]
机构
[1] Univ Louisville, Speed Sci Sch, Dept Chem Engn, Louisville, KY 40292 USA
[2] Univ Maryland Baltimore Cty, Dept Chem & Biochem Engn, Baltimore, MD 21250 USA
来源
COMPARATIVE BIOCHEMISTRY AND PHYSIOLOGY A-MOLECULAR AND INTEGRATIVE PHYSIOLOGY | 2002年 / 132卷 / 01期
关键词
breast cancer detection; near infrared (NIR); optical imaging; time resolved spectroscopy (TRS); transmittance; tumor depth; optical mammogram;
D O I
10.1016/S1095-6433(01)00523-2
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Breast cancer causes the death of more than 150 000 women in the United States each year. Pregnant women cannot undergo mammography due to its dangerous side effects and, for younger women, a mammogram does not differentiate tumor from their dense breast tissue. Breast tumors usually become a localized absorber in the near infrared (NIR) wavelength region, because of the increased hemoglobin concentration around the area of the tumor. Therefore, NIR has a high potential to detect breast cancer without side effects. A computer simulation solving the photon transfer equation was used to study the detectability of various tumor sizes embedded in the breast model at various depths. for both reflectance and transmittance. Previous reflectance studies demonstrated that increasing the S-D separation does not necessarily allow the photons to penetrate deeper in the medium. The optimum S-D separation for breast tissue was found to be 3.0 cm, where the light penetrates up to 1.7 cm. Studies on the photon path in transmittance demonstrate that, at high modulation frequencies, (e.g. 1.0 GHz). the photon path becomes more coherent. Therefore. for transmittance measurements. high modulation frequencies can be useful to localize deep tumors. Multi frequency, multi- S-D separation reflectance can be used to provide information on tumor depth. (C) 2002 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:9 / 15
页数:7
相关论文
共 5 条
[1]  
BRULEY DF, 1974, COMMUNICATION
[2]   Determination of a biological absorber depth utilizing multiple source-detector separations and multiple frequency values of near-infrared time-resolved spectroscopy [J].
Hemelt, MW ;
Kang, KA .
BIOTECHNOLOGY PROGRESS, 1999, 15 (04) :622-629
[3]  
HONAR AL, P 1999 ANN INT SOC O
[4]   HIGHLY SCATTERING OPTICAL-SYSTEM IDENTIFICATION VIA FREQUENCY-RESPONSE ANALYSIS OF NIR-TRS SPECTRA [J].
KANG, KA ;
BRULEY, DF ;
LONDONO, JM ;
CHANCE, B .
ANNALS OF BIOMEDICAL ENGINEERING, 1994, 22 (03) :240-252
[5]  
TROY TL, 1999, APPL OPTICS, V38, P5480