The quest for "diagnostically lossless" medical image compression: A comparative study of objective quality metrics for compressed medical images

被引:11
作者
Kowalik-Urbaniak, Ilona [1 ]
Brunet, Dominique [1 ]
Wang, Jiheng [2 ]
Koff, David [3 ]
Smolarski-Koff, Nadine [3 ]
Vrscay, Edward R. [1 ]
Wallace, Bill [4 ]
Wang, Zhou [2 ]
机构
[1] Univ Waterloo, Dept Appl Math, Waterloo, ON N2L 3G1, Canada
[2] Univ Waterloo, Dept Elect & Comp Engn, Waterloo, ON N2L 3G1, Canada
[3] McMaster Univ, Dept Radiol, Hamilton, ON L8S 4L8, Canada
[4] Agfa Healthcare Inc, Waterloo, ON, Canada
来源
MEDICAL IMAGING 2014: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT | 2014年 / 9037卷
关键词
image quality assessment; JPEG; JPEG2000; medical images; medical image compression; SSIM; compression ratio; image quality;
D O I
10.1117/12.2043196
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Our study, involving a collaboration with radiologists (DK, NSK) as well as a leading international developer of medical imaging software (AGFA), is primarily concerned with improved methods of assessing the diagnostic quality of compressed medical images and the investigation of compression artifacts resulting from JPEG and JPEG2000. In this work, we compare the performances of the Structural Similarity quality measure (SSIM), MSE/PSNR, compression ratio CR and JPEG quality factor Q, based on experimental data collected in two experiments involving radiologists. An ROC and Kolmogorov-Smirnov analysis indicates that compression ratio is not always a good indicator of visual quality. Moreover, SSIM demonstrates the best performance, i.e., it provides the closest match to the radiologists' assessments. We also show that a weighted Youden index(1) and curve fitting method can provide SSIM and MSE thresholds for acceptable compression ratios.
引用
收藏
页数:16
相关论文
共 9 条
[1]  
Hastie T., 2009, ELEMENTS STAT LEARNI, DOI DOI 10.1007/978-0-387-84858-7
[2]   Pan-Canadian Evaluation of Irreversible Compression Ratios ("Lossy" Compression) for Development of National Guidelines [J].
Koff, David ;
Bak, Peter ;
Brownrigg, Paul ;
Hosseinzadeh, Danoush ;
Khademi, April ;
Kiss, Alex ;
Lepanto, Luigi ;
Michalak, Tracy ;
Shulman, Harry ;
Volkening, Andrew .
JOURNAL OF DIGITAL IMAGING, 2009, 22 (06) :569-578
[3]  
Koff DA, 2006, CAN ASSOC RADIOL J, V57, P211
[4]  
Kowalik-Urbaniak I., 2012, P SPIE, V8319
[5]  
*U WAT, SSIM INDEX IMAGE QUA
[6]   Image quality assessment: From error visibility to structural similarity [J].
Wang, Z ;
Bovik, AC ;
Sheikh, HR ;
Simoncelli, EP .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 2004, 13 (04) :600-612
[7]   Mean Squared Error: Love It or Leave It? A new look at signal fidelity measures [J].
Wang, Zhou ;
Bovik, Alan C. .
IEEE SIGNAL PROCESSING MAGAZINE, 2009, 26 (01) :98-117
[8]  
YOUDEN WJ, 1950, BIOMETRICS, V6, P172, DOI 10.1002/1097-0142(1950)3:1<32::AID-CNCR2820030106>3.0.CO
[9]  
2-3