Determination of betaxolol in human aqueous humour by high-performance liquid chromatography with fluorescence detection

被引:18
|
作者
Dulger, B [1 ]
Basci, NE
Sagdic-Yalvac, I
Temizer, A
机构
[1] Hacettepe Univ, Fac Pharm, Dept Analyt Chem, TR-06100 Ankara, Turkey
[2] Hacettepe Univ, Fac Pharm, Turkish Doping Control Ctr, TR-06100 Ankara, Turkey
[3] Ankara Hosp, Dept Ophthalmol, Ankara, Turkey
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 772卷 / 01期
关键词
fluorescence detection; betaxolol; beta-blocker;
D O I
10.1016/S1570-0232(02)00023-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A reversed-phase high-performance liquid chromatographic method is described for the determination of betaxolol in human aqueous humour. Betaxolol and the internal standard metoprolol were extracted with cyclohexane and separated on a reversed-phase column (Luna C-18, 250x4.6 mm, 5 mum) with a mobile phase containing acetonitrile-phosphate buffer (40:60, v/v) at a flow-rate of 0.8 ml/min. The column effluent was monitored with a fluorescence detector at 227 nm (excitation) and 301 nm (emission). The retention times for metoprolol and betaxolol were 3.55 and 5.63 min, respectively. The recovery from aqueous humour was found to be 71.6% for betaxolol at 1.25 mug/ml. The within-day and day-to-day accuracy values were in the range of 96.17-105.2% for betaxolol at 0.1, 4 and 12 mug/ml (n=6), within-day and day-to-day precision values were less than 10% for betaxolol at the concentrations given above, The detection limit corresponding to the signal-to-noise ratio of 3:1 was 15 ng/ml. The presented method was suitable for measuring betaxolol levels in human aqueous humour samples obtained from patients after topical administration. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:179 / 183
页数:5
相关论文
共 50 条
  • [31] Determination of celiprolol in human plasma using high performance liquid chromatography with fluorescence detection for clinical application
    Itohda, Akiko
    Tsutsumi, Kimiko
    Imai, Hiromitsu
    Iwao, Miyuki
    Kotegawa, Tsutomu
    Ohashi, Kyoichi
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 904 : 88 - 92
  • [32] Smartphone as a fluorescence detector for high-performance liquid chromatography
    Shamsaei, Danial
    Hsieh, Shu-An
    Ocana-Rios, Iran
    Ryan, Saxon J.
    Anderson, Jared L.
    ANALYTICA CHIMICA ACTA, 2023, 1280
  • [33] DETERMINATION OF A BIGUANIDE, METFORMIN, BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PRECOLUMN FLUORESCENCE DERIVATIZATION
    OHTA, M
    IWASAKI, M
    KAI, M
    OHKURA, Y
    ANALYTICAL SCIENCES, 1993, 9 (02) : 217 - 220
  • [34] High-performance liquid chromatography assay with fluorescence detection for the evaluation of inhibitors against human recombinant monoacylglycerol lipase
    Holdrerich, Angela
    Makharadze, Teona
    Lehr, Matthias
    ANALYTICAL BIOCHEMISTRY, 2010, 399 (02) : 218 - 224
  • [35] Quantification of Lipopeptides Using High-performance Liquid Chromatography with Fluorescence Detection after Derivatization
    Meng, Yong
    Liu, Jin-Feng
    Yang, Shi-Zhong
    Ye, Ru-Qiang
    Mu, Bo-Zhong
    ANALYTICAL SCIENCES, 2015, 31 (05) : 377 - 382
  • [36] Quantification of Lipopeptides Using High-performance Liquid Chromatography with Fluorescence Detection after Derivatization
    Yong Meng
    Jin-Feng Liu
    Shi-Zhong Yang
    Ru-Qiang Ye
    Bo-Zhong Mu
    Analytical Sciences, 2015, 31 : 377 - 382
  • [37] DETERMINATION OF NICOTINIC-ACID AND NICOTINAMIDE IN HUMAN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH POSTCOLUMN ULTRAVIOLET-IRRADIATION AND FLUORESCENCE DETECTION
    MAWATARI, K
    IINUMA, F
    WATANABE, M
    ANALYTICAL SCIENCES, 1991, 7 (05) : 733 - 736
  • [38] Determination of ochratoxin A in Portuguese rice samples by high performance liquid chromatography with fluorescence detection
    Pena, A
    Cerejo, F
    Lino, C
    Silveira, I
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (05) : 1288 - 1293
  • [39] Determination of ochratoxin A in Portuguese rice samples by high performance liquid chromatography with fluorescence detection
    A. Pena
    F. Cerejo
    C. Lino
    I. Silveira
    Analytical and Bioanalytical Chemistry, 2005, 382 : 1288 - 1293
  • [40] High-performance liquid chromatography-photochemical reduction in aerobic conditions for determination of K vitamins using fluorescence detection
    Perez-Ruiz, Tomas
    Martinez-Lozano, Carmen
    Garcia, Ma Dolores
    Martin, Jesus
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1141 (01) : 67 - 72