In vitro wear of different material combinations of Intracoronal precision attachments

被引:0
|
作者
Holst, Stefan
Blatz, Markus B.
Eitner, Stephan
Wichmann, Manfred
机构
[1] Univ Erlangen Nurnberg, Dept Prosthodont, D-91054 Erlangen, Germany
[2] Louisiana State Univ, Hlth Sci Ctr, Sch Dent, Dept Prosthodont, New Orleans, LA USA
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study examined the retentive forces of intracoronal precision attachments after wear cycling. Materials and Methods: Three material combinations of an intracoronal cylindric T-attachment were tested. A total of 10,000 separating and joining movements were performed, and retentive forces were measured. Results: Components made of gold alloy performed significantly better (P =.002) than other materials. The average proportional loss of retention was 90% for titanium and 47% for gold alloy components. Conclusion: Cyclic loading of metal precision attachment components results in loss of retention, which can be fully compensated by reactivating internal screws in the patrices. Machined, high-noble gold alloys show less wear than other materials.
引用
收藏
页码:330 / 332
页数:3
相关论文
共 50 条
  • [41] Influence of different adherend materials and combinations on in vitro shear bond strength
    Zhang, Xiang
    Chai, Zhi-guo
    Wang, Hui
    Wang, Ying-jie
    Chen, Ji-hua
    DENTAL MATERIALS JOURNAL, 2013, 32 (04) : 622 - 627
  • [42] In vitro genotoxic effects of different combinations of cobalt and metallic carbide particles
    De Boeck, M
    Lombaert, N
    De Backer, S
    Finsy, R
    Lison, D
    Kirsch-Volders, M
    MUTAGENESIS, 2003, 18 (02) : 177 - 186
  • [43] Analysis of enamel and material wear by digital microscope: an in-vitro study
    Habib, Syed Rashid
    Ansari, Abdul Sadekh
    Alqahtani, Mohammed
    Alshiddi, Ibrahim F.
    Alqahtani, Abdulaziz S.
    Hassan, Syed Hammad
    BRAZILIAN ORAL RESEARCH, 2019, 33
  • [44] In-Vitro Evaluation of Friction for Forces in Different Brackets and Archwires Combinations
    Yuzbas, Berna
    Arun, Tulin
    TURKISH JOURNAL OF ORTHODONTICS, 2011, 24 (03) : 193 - 201
  • [45] Comparison Between Different Composite Resins Used for Clear Aligner Attachments: An In-Vitro Study
    Gazzani, Francesca
    Bellisario, Denise
    Quadrini, Fabrizio
    Parrinello, Francesca
    Pavoni, Chiara
    Cozza, Paola
    Lione, Roberta
    FRONTIERS IN MATERIALS, 2022, 8
  • [46] Analysis of polyethylene particles produced in different wear conditions in vitro
    Calonius, O
    Saikko, V
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (399) : 219 - 230
  • [47] The measurement in vitro of enamel and dentine wear by toothpastes of different abrasivity
    Philpotts, CJ
    Weader, E
    Joiner, A
    INTERNATIONAL DENTAL JOURNAL, 2005, 55 (03) : 183 - 187
  • [48] O-Ring Attachments on One-Piece Mini Dental implants: In Vitro Analysis of Retention Force Reproducibility Using Different Pristine Matrix-O-Ring Combinations
    Abou-Ayash, Samir
    Schimmel, Martin
    Worni, Andreas
    Enkling, Norbert
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2023, 36 (01) : 59 - 62
  • [49] Influence of material combinations and lubricants on friction and wear in ceramic-on-ceramic sliding pairs for joint prostheses
    Murakami, T
    Doi, S
    BIOCERAMICS 14, 2002, 218-2 : 521 - 524
  • [50] A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements
    Goldsmith, AAJ
    Dowson, D
    Isaac, GH
    Lancaster, JG
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2000, 214 (H1) : 39 - 47