In vitro wear of different material combinations of Intracoronal precision attachments

被引:0
|
作者
Holst, Stefan
Blatz, Markus B.
Eitner, Stephan
Wichmann, Manfred
机构
[1] Univ Erlangen Nurnberg, Dept Prosthodont, D-91054 Erlangen, Germany
[2] Louisiana State Univ, Hlth Sci Ctr, Sch Dent, Dept Prosthodont, New Orleans, LA USA
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study examined the retentive forces of intracoronal precision attachments after wear cycling. Materials and Methods: Three material combinations of an intracoronal cylindric T-attachment were tested. A total of 10,000 separating and joining movements were performed, and retentive forces were measured. Results: Components made of gold alloy performed significantly better (P =.002) than other materials. The average proportional loss of retention was 90% for titanium and 47% for gold alloy components. Conclusion: Cyclic loading of metal precision attachment components results in loss of retention, which can be fully compensated by reactivating internal screws in the patrices. Machined, high-noble gold alloys show less wear than other materials.
引用
收藏
页码:330 / 332
页数:3
相关论文
共 50 条
  • [21] ACCURACY OF DIFFERENT DIE STONE AND IMPRESSION MATERIAL COMBINATIONS
    PRICE, RB
    GERROW, JD
    SUTOW, EJ
    MACSWEEN, R
    JOURNAL OF DENTAL RESEARCH, 1990, 69 : 222 - 222
  • [22] The Effect of Different Water Temperatures on Retention Loss and Material Degradation of Locator Attachments
    Chiu, Lillian Pui Yuk
    Di Vitale, Nicola
    Petridis, Haralampos
    McDonald, Ailbhe
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2017, 26 (06): : 537 - 544
  • [23] Influence of the antagonist material on the wear of different composites using two different wear simulation methods
    Heintze, SD
    Zellweger, G
    Cavalleri, A
    Ferracane, J
    DENTAL MATERIALS, 2006, 22 (02) : 166 - 175
  • [24] Influence of surface energy on wear for various material combinations in hip joint replacements
    Huber, J
    Walter, A
    Plitz, W
    Refior, HJ
    BIOMEDIZINISCHE TECHNIK, 1996, 41 (1-2): : 32 - 34
  • [25] EFFECT OF DIFFERENT MEDIA ON IN VITRO STUDIES OF ANTIBIOTIC COMBINATIONS
    BULGER, RJ
    NIELSON, K
    APPLIED MICROBIOLOGY, 1968, 16 (06) : 890 - &
  • [26] IN-VITRO HEMOPERFUSION OF KIDNEYS IN DIFFERENT SPECIES COMBINATIONS
    LAND, W
    CORRELL, J
    PIELSTICKER, K
    BRENDEL, W
    RESEARCH IN EXPERIMENTAL MEDICINE, 1973, 159 (04) : 276 - 287
  • [27] In-vitro wear of different ceramic couplings
    Oberbach, T.
    Begand, S.
    Glien, W.
    BIOCERAMICS, VOL 19, PTS 1 AND 2, 2007, 330-332 : 1231 - +
  • [28] Wear resistance of orthodontic attachments: a comparative analysis of different composite resins in clear aligner therapy
    Irmak Ocak
    Hande Gorucu-Coskuner
    Muge Aksu
    Clinical Oral Investigations, 29 (5)
  • [29] Retention force assessment in conical crowns in different material combinations
    Pietruski, Jan K.
    Sajewicz, Eugeniusz
    Sudnik, Jacek
    Pietruska, Malgorzata D.
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2013, 15 (01) : 35 - 42
  • [30] Translucency of ceramic material in different core-veneer combinations
    Kursoglu, Pinar
    Motro, Pelin F. Karagoz
    Kazazoglu, Ender
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (01): : 48 - 53