LOW NOISE MEASUREMENT OF PHOTOCURRENT FOR CONTINUOUS GLUCOSE MONITORING Low Noise Measurement System Enables Continuous Monitoring of Glucose in Subcutaneous Interstitial Fluid

被引:0
作者
Cooley, Daniel W. [1 ]
Andersen, David R. [1 ,2 ]
机构
[1] Univ Iowa, Dept Elect & Comp Engn, 132 IATL, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Phys, Iowa City, IA USA
来源
BIODEVICES 2010: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES | 2010年
关键词
Continuous glucose monitoring; IR photodiode; Transimpedance amplifier;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a data acquisition unit (DAU) for continuous, low noise measurement of glucose concentration in subcutaneous interstitial fluid (ISF). The system is comprised of a glucose sensor (Olesberg, 2006), op-amps for signal conditioning, and delta-sigma (Delta-Sigma) ADCs. The glucose sensor has two IR LEDs which emit light with wavelength of 2.2 to 2.4 mu m where there are peaks in the glucose absorption spectrum. The IR light propagates through a glass fluid chamber containing interstitial fluid and a linearly variable bandpass filter before impinging on a 32 channel photodiode array. The center frequency of the filter varies along one dimension of the filter, so that each photodiode is sensitive to equally spaced portions of the glucose absorption spectrum. Transimpedance amplifiers (TIAs) convert the photocurrents into voltages which are sampled by ADCs. We developed a noise model which predicts the noise characteristics of the system. We use low noise metal film resistors to verify the DAU noise characteristics. Non-ideal characteristics such as limited photocurrent and low photodiode shunt resistance increase difficulty of obtaining low noise measurements. We demonstrate that the DAU provides low noise (41.7 dB SNR) photocurrent measurements and is suitable for use in a continuous glucose monitoring system.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
  • [31] Assessing Glycemic Control in Diabetes: From Self Monitoring of Blood Glucose to Continuous Glucose Monitoring System
    Gribovschi, M.
    Fodor, A.
    Grosu, G.
    Hancu, N.
    [J]. INTERNATIONAL CONFERENCE ON ADVANCEMENTS OF MEDICINE AND HEALTH CARE THROUGH TECHNOLOGY, 2009, 26 : 29 - +
  • [32] Switching from Intermittently Scanned Continuous Glucose Monitoring to Real-Time Continuous Glucose Monitoring with a Predictive Urgent Low Soon Alert Reduces Exposure to Hypoglycemia
    Preechasuk, Lukana
    Avari, Parizad
    Oliver, Nick
    Reddy, Monika
    [J]. DIABETES TECHNOLOGY & THERAPEUTICS, 2024, 26 (07) : 498 - 502
  • [33] A pilot study to evaluate a novel subcutaneous continuous glucose monitoring system in healthy Beagle dogs
    Affenzeller, Nadja
    Benesch, Thomas
    Thalhammer, Johann G.
    Willmann, Michael
    [J]. VETERINARY JOURNAL, 2010, 184 (01) : 105 - 110
  • [34] Comparison of Glucose Area Under the Curve Measured Using Minimally Invasive Interstitial Fluid Extraction Technology with Continuous Glucose Monitoring System in Diabetic Patients
    Uemura, Mei
    Yano, Yutaka
    Suzuki, Toshinari
    Yasuma, Taro
    Sato, Toshiyuki
    Morimoto, Aya
    Hosoya, Samiko
    Suminaka, Chihiro
    Nakajima, Hiromu
    Gabazza, Esteban C.
    Takei, Yoshiyuki
    [J]. DIABETES & METABOLISM JOURNAL, 2017, 41 (04) : 265 - 274
  • [35] Continuous glucose monitoring and external insulin pump: towards a subcutaneous closed loop
    Hanaire, H.
    [J]. DIABETES & METABOLISM, 2006, 32 (05) : 534 - 538
  • [36] Bayesian denoising algorithm dealing with colored, non-stationary noise in continuous glucose monitoring timeseries
    Camerlingo, Nunzio
    Siviero, Ilaria
    Vettoretti, Martina
    Sparacino, Giovanni
    Del Favero, Simone
    Facchinetti, Andrea
    [J]. FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2023, 11
  • [37] An integrated wearable differential microneedle array for continuous glucose monitoring in interstitial fluids
    Yang, Yong
    Sheng, Can
    Dong, Fang
    Liu, Sheng
    [J]. BIOSENSORS & BIOELECTRONICS, 2024, 256
  • [38] Evaluation of the performance and usability of a novel continuous glucose monitoring system
    Yan, Li
    Li, Qiang
    Guan, Qingbo
    Han, Mingsong
    Zhao, Yu
    Fang, Junfei
    Zhao, Jiajun
    [J]. INTERNATIONAL JOURNAL OF DIABETES IN DEVELOPING COUNTRIES, 2023, 43 (04) : 551 - 558
  • [39] Evaluation of the performance and usability of a novel continuous glucose monitoring system
    Li Yan
    Qiang Li
    Qingbo Guan
    Mingsong Han
    Yu Zhao
    Junfei Fang
    Jiajun Zhao
    [J]. International Journal of Diabetes in Developing Countries, 2023, 43 : 551 - 558
  • [40] Benefits and Limitations of MARD as a Performance Parameter for Continuous Glucose Monitoring in the Interstitial Space
    Heinemann, Lutz
    Schoemaker, Michael
    Schmelzeisen-Redecker, Guenther
    Hinzmann, Rolf
    Kassab, Adham
    Freckmann, Guido
    Reiterer, Florian
    Del Re, Luigi
    [J]. JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2020, 14 (01): : 135 - 150