LOW NOISE MEASUREMENT OF PHOTOCURRENT FOR CONTINUOUS GLUCOSE MONITORING Low Noise Measurement System Enables Continuous Monitoring of Glucose in Subcutaneous Interstitial Fluid

被引:0
作者
Cooley, Daniel W. [1 ]
Andersen, David R. [1 ,2 ]
机构
[1] Univ Iowa, Dept Elect & Comp Engn, 132 IATL, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Phys, Iowa City, IA USA
来源
BIODEVICES 2010: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES | 2010年
关键词
Continuous glucose monitoring; IR photodiode; Transimpedance amplifier;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a data acquisition unit (DAU) for continuous, low noise measurement of glucose concentration in subcutaneous interstitial fluid (ISF). The system is comprised of a glucose sensor (Olesberg, 2006), op-amps for signal conditioning, and delta-sigma (Delta-Sigma) ADCs. The glucose sensor has two IR LEDs which emit light with wavelength of 2.2 to 2.4 mu m where there are peaks in the glucose absorption spectrum. The IR light propagates through a glass fluid chamber containing interstitial fluid and a linearly variable bandpass filter before impinging on a 32 channel photodiode array. The center frequency of the filter varies along one dimension of the filter, so that each photodiode is sensitive to equally spaced portions of the glucose absorption spectrum. Transimpedance amplifiers (TIAs) convert the photocurrents into voltages which are sampled by ADCs. We developed a noise model which predicts the noise characteristics of the system. We use low noise metal film resistors to verify the DAU noise characteristics. Non-ideal characteristics such as limited photocurrent and low photodiode shunt resistance increase difficulty of obtaining low noise measurements. We demonstrate that the DAU provides low noise (41.7 dB SNR) photocurrent measurements and is suitable for use in a continuous glucose monitoring system.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
[21]   Continuous Monitoring of Interstitial Fluid Glucose Responses to Endurance Exercise with Different Levels of Carbohydrate Intake [J].
Hiromatsu, Chiyori ;
Kasahara, Naoto ;
Lin, Chao-An ;
Wang, Feifei ;
Goto, Kazushige .
NUTRIENTS, 2023, 15 (22)
[22]   An Interstitial Fluid Transdermal Extraction Chip with Vacuum Generator and Volume Sensor for Continuous Glucose Monitoring [J].
Yu, Haixia ;
Li, Dachao ;
Ji, Yongjie ;
Zhang, Xiaoli ;
Xu, Kexin .
MICRO-NANO TECHNOLOGY XIV, PTS 1-4, 2013, 562-565 :571-575
[23]   Low-Cost and Easy-to-Fabricate Microwave Sensor for Sensitive Glucose Monitoring: A Step Towards Continuous Glucose Monitoring [J].
Tahmid, Ahnaf ;
Rahman, Tanzim ;
Emam, S. M. Ali ;
Reza, Syeda Maliha ;
Hosen, Md Ismail ;
Inum, Reefat ;
Habib, Ahsan .
IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY, 2024,
[24]   The use of a continuous glucose monitoring system in hypoglycemic disorders [J].
Conrad, SC ;
Mastrototaro, JJ ;
Gitelman, SE .
JOURNAL OF PEDIATRIC ENDOCRINOLOGY & METABOLISM, 2004, 17 (03) :281-288
[25]   Continuous glucose monitoring in very low birth weight infants - a systematic review [J].
Ribeiro, Tiago ;
Guimaraes, Hercilia ;
Soares, Henrique .
JOURNAL OF PEDIATRIC AND NEONATAL INDIVIDUALIZED MEDICINE, 2023, 12 (01)
[26]   The Role of Continuous Glucose Monitoring System Profiles in Diabetes [J].
Monnier, L. ;
Colette, C. ;
Owens, D. .
DIABETES STOFFWECHSEL UND HERZ, 2008, 17 :S17-S22
[27]   Wearable microdialysis system for continuous in vivo monitoring of glucose [J].
Vering, T ;
Adam, S ;
Drewer, H ;
Dumschat, C ;
Steinkuhl, R ;
Schulze, A ;
Siegel, EG ;
Knoll, M .
ANALYST, 1998, 123 (07) :1605-1609
[28]   Current status of continuous subcutaneous insulin infusion and continuous glucose monitoring systems in the Community of Madrid [J].
Arranz Martin, Alfonso ;
Calle Pascual, Alfonso ;
Javier del Canizo Gomez, Francisco ;
Gonzalez Albarran, Olga ;
Lisbona Gil, Arturo ;
Botella Serrano, Marta ;
Pallardo Sanchez, Luis Felipe .
ENDOCRINOLOGIA Y NUTRICION, 2015, 62 (04) :171-179
[29]   Postprandial glucose monitoring in type 1 diabetes mellitus: use of a continuous subcutaneous monitoring device [J].
Manuel-y-Keenoy, B ;
Vertommen, J ;
Abrams, P ;
Van Gaal, L ;
De Leeuw, I ;
Messeri, D ;
Poscia, A .
DIABETES-METABOLISM RESEARCH AND REVIEWS, 2004, 20 :S24-S31
[30]   Estimating Plasma Glucose from Interstitial Glucose: The Issue of Calibration Algorithms in Commercial Continuous Glucose Monitoring Devices [J].
Rossetti, Paolo ;
Bondia, Jorge ;
Vehi, Josep ;
Fanelli, Carmine G. .
SENSORS, 2010, 10 (12) :10936-10952