LOW NOISE MEASUREMENT OF PHOTOCURRENT FOR CONTINUOUS GLUCOSE MONITORING Low Noise Measurement System Enables Continuous Monitoring of Glucose in Subcutaneous Interstitial Fluid

被引:0
|
作者
Cooley, Daniel W. [1 ]
Andersen, David R. [1 ,2 ]
机构
[1] Univ Iowa, Dept Elect & Comp Engn, 132 IATL, Iowa City, IA 52242 USA
[2] Univ Iowa, Dept Phys, Iowa City, IA USA
来源
BIODEVICES 2010: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES | 2010年
关键词
Continuous glucose monitoring; IR photodiode; Transimpedance amplifier;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We have developed a data acquisition unit (DAU) for continuous, low noise measurement of glucose concentration in subcutaneous interstitial fluid (ISF). The system is comprised of a glucose sensor (Olesberg, 2006), op-amps for signal conditioning, and delta-sigma (Delta-Sigma) ADCs. The glucose sensor has two IR LEDs which emit light with wavelength of 2.2 to 2.4 mu m where there are peaks in the glucose absorption spectrum. The IR light propagates through a glass fluid chamber containing interstitial fluid and a linearly variable bandpass filter before impinging on a 32 channel photodiode array. The center frequency of the filter varies along one dimension of the filter, so that each photodiode is sensitive to equally spaced portions of the glucose absorption spectrum. Transimpedance amplifiers (TIAs) convert the photocurrents into voltages which are sampled by ADCs. We developed a noise model which predicts the noise characteristics of the system. We use low noise metal film resistors to verify the DAU noise characteristics. Non-ideal characteristics such as limited photocurrent and low photodiode shunt resistance increase difficulty of obtaining low noise measurements. We demonstrate that the DAU provides low noise (41.7 dB SNR) photocurrent measurements and is suitable for use in a continuous glucose monitoring system.
引用
收藏
页码:195 / 200
页数:6
相关论文
共 50 条
  • [1] An Interstitial Fluid Transdermal Extraction System for Continuous Glucose Monitoring
    Yu, Haixia
    Li, Dachao
    Roberts, Robert C.
    Xu, Kexin
    Tien, Norman C.
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2012, 21 (04) : 917 - 925
  • [2] Continuous glucose monitoring in interstitial fluid using glucose oxidase-based sensor compared to established blood glucose measurement in rats
    Woderer, Stefanie
    Henninger, Nadja
    Garthe, Claus-Dieter
    Kloetzer, Hans Martin
    Hajnsek, Martin
    Kamecke, Ulrike
    Gretz, Norbert
    Kraenzlin, Bettina
    Pill, Johannes
    ANALYTICA CHIMICA ACTA, 2007, 581 (01) : 7 - 12
  • [3] Continuous Glucose Monitoring by Real Time Sensor in Interstitial Fluid
    Honsova, Sarka
    Navratil, Tomas
    XXXIII MODERNI ELEKTROCHEMICKE METODY, 2013, : 63 - 67
  • [4] Measurement delay associated with the Guardian® RT continuous glucose monitoring system
    Wei, C.
    Lunn, D. J.
    Acerini, C. L.
    Allen, J. M.
    Larsen, A. M.
    Wilinska, M. E.
    Dunger, D. B.
    Hovorka, R.
    DIABETIC MEDICINE, 2010, 27 (01) : 117 - 122
  • [5] A low-power miniaturized microelectronic system for continuous glucose monitoring
    Croce Jr., Robert A.
    Vaddiraju, Santhisagar
    Legassey, Allen
    Papadimitrakopoulos, Fotios
    Jain, Faquir C.
    International Journal of High Speed Electronics and Systems, 2014, 23 (1-2)
  • [6] Glucose measurement in interstitial fluid by microdialysis for the calibration of minimally invasive blood glucose monitoring
    Li, Dachao
    Wang, Ridong
    Chong, Hao
    Liu, Yu
    Xu, Kexin
    ADVANCED BIOMEDICAL AND CLINICAL DIAGNOSTIC SYSTEMS XI, 2013, 8572
  • [7] Measurement Performance of Two Continuous Tissue Glucose Monitoring Systems Intended for Replacement of Blood Glucose Monitoring
    Freckmann, Guido
    Link, Manuela
    Pleus, Stefan
    Westhoff, Antje
    Kamecke, Ulrike
    Haug, Cornelia
    DIABETES TECHNOLOGY & THERAPEUTICS, 2018, 20 (08) : 541 - 549
  • [8] Role of continuous subcutaneous glucose monitoring in intensive care
    Marics, Gabor
    Koncz, Levente
    Korner, Anna
    Mikos, Borbala
    Toth-Heyn, Peter
    ORVOSI HETILAP, 2013, 154 (27) : 1043 - 1048
  • [9] Consistency of Continuous Ambulatory Interstitial Glucose Monitoring Sensors
    Wu, Pei T.
    Segovia, David E.
    Lee, Cathy C.
    Nguyen, Kim-Lien
    BIOSENSORS-BASEL, 2018, 8 (02):
  • [10] Continuous glucose monitoring on the ICU using a subcutaneous sensor
    Punke, M. A.
    Decker, C.
    Wodack, K.
    Reuter, D. A.
    Kluge, S.
    MEDIZINISCHE KLINIK-INTENSIVMEDIZIN UND NOTFALLMEDIZIN, 2015, 110 (05) : 360 - 363