Repeatability of contrast sensitivity testing in patients with age-related macular degeneration, glaucoma, and cataract

被引:10
作者
Kara, Selcuk [1 ]
Gencer, Baran [1 ]
Ersan, Ismail [1 ]
Arikan, Sedat [1 ]
Kocabiyik, Omer [1 ]
Tufan, Hasan Ali [1 ]
Comez, ArzuTaskiran [1 ]
机构
[1] Canakkale Onsekiz Mart Univ, Dept Ophthalmol, Fac Med, Canakkale, Turkey
关键词
Macular degeneration; Contrast sensitivity; Glaucoma; Age effect; Re-producibility of results; VISUAL-ACUITY; PARVOCELLULAR PATHWAYS; LAMELLAR KERATOPLASTY; QUALITY; EYES; LIFE; ASSOCIATION; ABILITY; DESIGN; LASIK;
D O I
10.5935/0004-2749.20160092
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To analyze the intrasession and intersession repeatability of contrast sensitivity (CS) measurements in patients with glaucoma, cataract, or age-related macular degeneration (AMD) and healthy controls. Methods: CS measurements were performed using the OPTEC-Functional Vision Analyzer (FVA), which uses a standardized and closed (view-in) system. Measurements for patients with glaucoma, cataract, or AMD and healthy controls were repeated within 30 minutes (intrasession) and during two sessions (intersession), separated by one week to one month. Test-retest reliability and correlation were measured using the intraclass correlation coefficient (ICC) and coefficient of repeatability (COR). Results: Ninety subjects (90 eyes) with visual acuity of 0.17 logMAR or higher in the cataract group or 0.00 logMAR in the other groups were included. During the first session, the ICC values were 0.87, 0.90, 0.76, and 0.69, and COR values were 0.24, 0.20, 0.38, and 0.25 for the control, glaucoma, cataract, and AMD groups, respectively. The reliability scores significantly improved during the second session, except in the glaucoma group. There was an acceptable floor effect and no ceiling effect at higher frequencies in the glaucoma and AMD groups. Conclusion: In subjects with good visual acuity, the FVA system is useful for evaluating CS and demonstrates good repeatability, as shown by ICC and COR. Because there is no ceiling effect, this system is beneficial for evaluation of early changes in CS, particularly in patients with glaucoma or AMD.
引用
收藏
页码:323 / 327
页数:5
相关论文
共 40 条
[1]   Psychophysical characterisation of early functional loss in glaucoma and ocular hypertension [J].
Ansari, EA ;
Morgan, JE ;
Snowden, RJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2002, 86 (10) :1131-1135
[2]   Statistical guidelines for clinical studies of human vision [J].
Armstrong, Richard A. ;
Davies, Leon N. ;
Dunne, Mark C. M. ;
Gilmartin, Bernard .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2011, 31 (02) :123-136
[3]   Repeatability of visual function measures in age-related macular degeneration [J].
Aslam, Tariq ;
Mahmood, Sajjad ;
Balaskas, Konstantinos ;
Patton, Niall ;
Tanawade, Rajeev G. ;
Tan, Shi Zhuan ;
Roberts, Stephen A. ;
Parkes, Jeremy ;
Bishop, Paul N. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (02) :201-206
[4]   Determinants of health related quality of life and health state utility in patients with age related macular degeneration: the association of contrast sensitivity and visual acuity [J].
Bansback, N. ;
Czoski-Murray, C. ;
Carlton, J. ;
Lewis, G. ;
Hughes, L. ;
Espallargues, M. ;
Brand, C. ;
Brazier, J. .
QUALITY OF LIFE RESEARCH, 2007, 16 (03) :533-543
[5]   Estimating quality-adjusted life years from patient-reported visual functioning [J].
Browne, C. ;
Brazier, J. ;
Carlton, J. ;
Alavi, Y. ;
Jofre-Bonet, M. .
EYE, 2012, 26 (10) :1295-1301
[6]   Measuring contrast sensitivity under different lighting conditions: Comparison of three tests [J].
Department of Ophthalmology, Johann Wolfgang Goethe-University, Frankfurt am Main, Germany ;
不详 ;
不详 ;
不详 ;
不详 .
Optom. Vis. Sci., 2006, 5 (290-298) :290-298
[7]   THE LENS OPACITIES CLASSIFICATION SYSTEM-III [J].
CHYLACK, LT ;
WOLFE, JK ;
SINGER, DM ;
LESKE, MC ;
BULLIMORE, MA ;
BAILEY, IL ;
FRIEND, J ;
MCCARTHY, D ;
WU, SY .
ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (06) :831-836
[8]   EVALUATING CONTRAST SENSITIVITY IN AGE-RELATED MACULAR DEGENERATION USING A NOVEL COMPUTER-BASED TEST, THE SPAETH/RICHMAN CONTRAST SENSITIVITY TEST [J].
Faria, Bruno M. ;
Duman, Fulya ;
Zheng, Cindy X. ;
Waisbourd, Michael ;
Gupta, Lalita ;
Ali, Mohsin ;
Zangalli, Camila ;
Lu, Lan ;
Wizov, Sheryl S. ;
Spaeth, Eric ;
Richman, Jesse ;
Spaeth, George L. .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2015, 35 (07) :1465-1473
[9]   Refractive lenticule extraction (ReLEx flex) and wavefront-optimized Femto-LASIK: comparison of contrast sensitivity and high-order aberrations at 1 year [J].
Gertnere, Jana ;
Solomatin, Igor ;
Sekundo, Walter .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (05) :1437-1442
[10]   Contrast sensitivity: determining the visual quality and function of cataract, intraocular lenses and refractive surgery [J].