Measurement of the response function and the detection efficiency of an organic liquid scintillator for neutrons between 1 and 30 MeV

被引:18
作者
Huang Han-Xiong [1 ]
Ruan Xi-Chao [1 ]
Chen Guo-Chang [1 ]
Zhou Zu-Ying [1 ]
Li Xia [1 ]
Bao Jie [1 ]
Nie Yang-Bo [1 ]
Zhong Qi-Ping [1 ]
机构
[1] China Inst Atom Energy, Dept Nucl Phys, Beijing 102413, Peoples R China
关键词
liquid scintillator; response function; detection efficiency; Monte-Carlo; TOF; ENERGY-RANGE; NE213; CALIBRATION;
D O I
10.1088/1674-1137/33/8/015
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The light output function of a phi 50.8 min x 50.8 mm BC501A scintillation detector was measured in the neutron energy region of 1. to 30 MeV by fitting the pulse height (PH) spectra for neutrons with the simulations from the NRESP code at the edge range. Using the new light output function, the neutron detection efficiency was determined with two Monte-Carlo codes, NEFF and SCINFUL. The calculated efficiency was corrected by comparing the simulated PH spectra with the measured ones. The determined efficiency was verified at the near threshold region and normalized with a Proton-Recoil-Telescope (PRT) at the 8-14 MeV energy region.
引用
收藏
页码:677 / 681
页数:5
相关论文
共 12 条
[2]   MEASUREMENT OF THE DETECTION EFFICIENCY FOR 130 MEV NEUTRONS OF A CYLINDRICAL NE213 CELL BY THE ASSOCIATED PARTICLE METHOD [J].
DEBEVEC, PT ;
MOAKE, GL ;
QUIN, PA .
NUCLEAR INSTRUMENTS & METHODS, 1979, 166 (03) :467-471
[3]  
DICKENS JK, 1998, ORNL6463
[4]   GAMMA-CALIBRATION OF NE-213 SCINTILLATION-COUNTERS [J].
DIETZE, G ;
KLEIN, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 193 (03) :549-556
[5]  
DIETZE G, 1982, PTBND22, P1
[6]   EFFICIENCY CALIBRATION OF SCINTILLATION DETECTORS IN THE NEUTRON ENERGY-RANGE 1.5-25 MEV BY THE ASSOCIATED PARTICLE TECHNIQUE [J].
FOWLER, JL ;
COOKSON, JA ;
HUSSAIN, M ;
SCHWARTZ, RB ;
SWINHOE, MT ;
WISE, C ;
UTTLEY, CA .
NUCLEAR INSTRUMENTS & METHODS, 1980, 175 (2-3) :449-463
[7]   Measurements of the response function and the detection efficiency of an NE213 scintillator for neutrons between 20 and 65 MeV [J].
Meigo, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 401 (2-3) :365-378
[8]   Absolute measurements of the response function of an NE213 organic liquid scintillator for the neutron energy range up to 206 MeV [J].
Nakao, N ;
Kurosawa, T ;
Nakamura, T ;
Uwamino, Y .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 463 (1-2) :275-287
[9]  
QI BJ, 1997, QINGDAO U T, V10, P86
[10]  
Sa J., 1992, ATOMIC ENERGY SCI TE, V26, P1