Does dental fluorosis affect electric pulp test response and/or optimum probe placement site?

被引:3
|
作者
Idon, Paul I. [1 ]
Nwamba, Patricia N. [2 ]
Udoye, Christopher I. [3 ]
Jafarzadeh, Hamid [4 ]
机构
[1] Univ Maiduguri, Teaching Hosp, Dept Dent Surg, Maiduguri, Borno State, Nigeria
[2] Univ Nigeria, Teaching Hosp, Dept Restorat Dent, Enugu, Nigeria
[3] Univ Nigeria, Coll Med, Dept Restorat Dent, Nsukka, Enugu State, Nigeria
[4] Mashhad Univ Med Sci, Dent Res Ctr, Mashhad, Razavi Khorasan, Iran
关键词
dental fluorosis; electric pulp test; pulp sensibility test; HUMAN ENAMEL; FLUORIDE; MECHANISMS; MEDIA;
D O I
10.1111/aej.12479
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The placement site of electric pulp tester (EPT) probe on the tooth affects the threshold values obtained. The aim of this study was to determine and compare threshold levels and appropriate placement sites for EPT probe on fluorotic and normal teeth. Equal numbers of fluorotic and non-fluorotic maxillary central incisors of 40 subjects were assessed. The mean of three threshold readings from an EPT was taken from the labial surface at the incisal edge, incisal third, middle third and cervical third. Kruskal-Wallis and Friedman ANOVA followed by post hoc tests were used to compare threshold scores. Significantly higher thresholds were recorded for fluorotic teeth at the incisal edge and incisal third. The lowest thresholds were obtained for the incisal edge in both fluorotic and non-fluorotic teeth when compared to the cervical third. There was no statistically significant difference among corresponding test sites between the genders and age groups.
引用
收藏
页码:307 / 313
页数:7
相关论文
共 5 条
  • [1] Automatic stimulus breaker for electric dental pulp tester using pain response
    Nam, KC
    Lee, SJ
    Song, CG
    Kim, DW
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (03) : 375 - 378
  • [2] Automatic stimulus breaker for electric dental pulp tester using pain response
    K. C. Nam
    S. J. Lee
    C. G. Song
    D. W. Kim
    Medical and Biological Engineering and Computing, 2005, 43 : 375 - 378
  • [3] Reliability of electric pulp test and thermal pulp test for assessing pulpal response in patients undergoing orthodontic treatment - A systematic review
    Nangia, Divya
    Duggal, Isha
    Logani, Ajay
    Sharma, Sidhartha
    Duggal, Ritu
    INTERNATIONAL ORTHODONTICS, 2025, 23 (01)
  • [4] Identification of the Ideal Reference Site and Pain Threshold Values for the Placement of Electric Pulp Testers in Permanent Upper and Lower Anterior Teeth: A Cross-Sectional Study
    Saikiran, Kanamarlapudi V.
    Gurunathan, Deepa
    Gayathri, Esha
    Nuvvula, Sivakumar
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (04)
  • [5] How Does the Visualization Technique Affect the Design Process? Using Sketches, Real Products and Virtual Models to Test the User's Emotional Response
    Alonso-Garcia, Maria
    Palacios-Ibanez, Almudena
    de-Cozar-Macias, Oscar D.
    Marin-Granados, Manuel D.
    INTERNATIONAL JOURNAL OF INTERACTIVE MULTIMEDIA AND ARTIFICIAL INTELLIGENCE, 2024, 9 (01): : 112 - 126