Detection of feline coronavirus using microcantilever sensors

被引:29
作者
Velanki, Sreepriya
Ji, Hai-Feng
机构
[1] Louisiana Tech Univ, Chem Program, Ruston, LA 71270 USA
[2] Louisiana Tech Univ, Inst Micromfg, Ruston, LA 71270 USA
关键词
microcantilever; feline coronavirus (FIP) detection; SARS detection; adsorption-induced surface stress;
D O I
10.1088/0957-0233/17/11/015
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This work demonstrated the feasibility of detecting severe acute respiratory syndrome associated coronavirus (SARS-CoV) using microcantilever technology by showing that the feline coronavirus (FIP) type I virus can be detected by a microcantilever modified by feline coronavirus (FIP) type I anti-viral antiserum. A microcantilever modified by FIP type I anti-viral antiserum was developed for the detection of FIP type I virus. When the FIP type I virus positive sample is injected into the fluid cell where the microcantilever is held, the microcantilever bends upon the recognition of the FIP type I virus by the antiserum on the surface of the microcantilever. A negative control sample that does not contain FIP type I virus did not cause any bending of the microcantilever. The detection limit of the sensor was 0.1 mu g ml(-1) when the assay time was < 1 h.
引用
收藏
页码:2964 / 2968
页数:5
相关论文
共 31 条
  • [1] A STUDY OF NATURALLY-OCCURRING FELINE CORONAVIRUS INFECTIONS IN KITTENS
    ADDIE, DD
    JARRETT, O
    [J]. VETERINARY RECORD, 1992, 130 (07) : 133 - 137
  • [2] Coronavirus main proteinase (3CLpro) structure:: Basis for design of anti-SARS drugs
    Anand, K
    Ziebuhr, J
    Wadhwani, P
    Mesters, JR
    Hilgenfeld, R
    [J]. SCIENCE, 2003, 300 (5626) : 1763 - 1767
  • [3] Antibody detection of SARS-CoV spike and nucleocapsid protein
    Chang, MS
    Lu, YT
    Ho, ST
    Wu, CC
    Wei, TY
    Chen, CJ
    Hsu, YT
    Chu, PC
    Chen, CH
    Chu, JM
    Jan, YL
    Hung, CC
    Fan, CC
    Yang, YC
    [J]. BIOCHEMICAL AND BIOPHYSICAL RESEARCH COMMUNICATIONS, 2004, 314 (04) : 931 - 936
  • [4] RESONANCE RESPONSE OF SCANNING FORCE MICROSCOPY CANTILEVERS
    CHEN, GY
    WARMACK, RJ
    THUNDAT, T
    ALLISON, DP
    HUANG, A
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (08) : 2532 - 2537
  • [5] ADSORPTION-INDUCED SURFACE STRESS AND ITS EFFECTS ON RESONANCE FREQUENCY OF MICROCANTILEVERS
    CHEN, GY
    THUNDAT, T
    WACHTER, EA
    WARMACK, RJ
    [J]. JOURNAL OF APPLIED PHYSICS, 1995, 77 (08) : 3618 - 3622
  • [6] Frequency modulation detection high vacuum scanning force microscope with a self-oscillating piezoelectric cantilever
    Chu, JR
    Itoh, T
    Lee, CK
    Suga, T
    Watanabe, K
    [J]. JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1997, 15 (05): : 1647 - 1651
  • [7] Translating biomolecular recognition into nanomechanics
    Fritz, J
    Baller, MK
    Lang, HP
    Rothuizen, H
    Vettiger, P
    Meyer, E
    Güntherodt, HJ
    Gerber, C
    Gimzewski, JK
    [J]. SCIENCE, 2000, 288 (5464) : 316 - 318
  • [8] OBSERVATION OF A CHEMICAL-REACTION USING A MICROMECHANICAL SENSOR
    GIMZEWSKI, JK
    GERBER, C
    MEYER, E
    SCHLITTLER, RR
    [J]. CHEMICAL PHYSICS LETTERS, 1994, 217 (5-6) : 589 - 594
  • [9] Piezoresistive sensors for scanning probe microscopy
    Gotszalk, T
    Grabiec, P
    Rangelow, IW
    [J]. ULTRAMICROSCOPY, 2000, 82 (1-4) : 39 - 48
  • [10] Isolation and characterization of viruses related to the SARS coronavirus from animals in Southern China
    Guan, Y
    Zheng, BJ
    He, YQ
    Liu, XL
    Zhuang, ZX
    Cheung, CL
    Luo, SW
    Li, PH
    Zhang, LJ
    Guan, YJ
    Butt, KM
    Wong, KL
    Chan, KW
    Lim, W
    Shortridge, KF
    Yuen, KY
    Peiris, JSM
    Poon, LLM
    [J]. SCIENCE, 2003, 302 (5643) : 276 - 278