Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement

被引:6
作者
Nguyen, Quoc Khanh [1 ,2 ]
Kim, Seungman [1 ]
Han, Seong-Heum [1 ]
Ro, Seung-Kook [1 ]
Kim, Seung-Woo [3 ]
Kim, Young-Jin [3 ]
Kim, Wooram [3 ]
Oh, Jeong Seok [1 ,2 ]
机构
[1] Korea Inst Machinery & Mat, Dept Ultraprecis Machines & Syst, Daejeon 34103, South Korea
[2] Univ Sci & Technol, Dept Nanomechatron, Daejeon 34113, South Korea
[3] Korea Adv Inst Sci & Technol, Dept Mech Engn, Daejeon 34141, South Korea
基金
新加坡国家研究基金会;
关键词
multilateration; self-calibration; absolute distance measurement; initial guess; TRACKING INTERFEROMETER SYSTEM; LARGE-SCALE METROLOGY; OF-FLIGHT MEASUREMENT; 3-DIMENSIONAL COORDINATE; LASER TRACKERS; ARRANGEMENT;
D O I
10.3390/s20247288
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multilateration tracking systems (MLTSs) are used in industrial three-dimensional (3D) coordinate measuring applications. For high-precision measurement, system parameters must be calibrated properly in advance. For an MLTS using absolute distance measurement (ADM), the conventional self-calibration method significantly reduces estimation efficiency because all system parameters are estimated simultaneously using a complicated residual function. This paper presents a novel self-calibration method that optimizes ADM to reduce the number of system parameters via highly precise and separate estimations of dead paths. Therefore, the residual function to estimate the tracking station locations can be simplified. By applying a suitable mathematical procedure and solving the initial guess problem without the aid of an external device, estimation accuracy of the system parameters is significantly improved. In three self-calibration experiments, with ADM repeatability of approximately 3.4 mu m, the maximum deviation of the system parameters estimated by the proposed self-calibration method was 68.6 mu m, while the maximum deviation estimated by the conventional self-calibration method was 711.9 mu m. Validation of 3D coordinate measurements in a 1000 mm x 1000 mm x 1000 mm volume showed good agreement between the proposed ADM-based MLTS and a commercial laser tracker, where the maximum difference based on the standard deviation was 17.7 mu m. Conversely, the maximum difference was 98.8 mu m using the conventional self-calibration method. These results confirmed the efficiency and feasibility of the proposed self-calibration method.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [41] An FPGA-based phase self-calibration system for micro-current sensor
    Chen, Gang
    Chen, Xu
    Chen, Tianxiang
    Gong, Guoliang
    Bian, Yi
    Lu, Huaxiang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2013, 37 (20): : 102 - 107
  • [42] Self-calibration of spherical rectification for a PTZ-stereo system
    Wan, Dingrui
    Zhou, Jie
    IMAGE AND VISION COMPUTING, 2010, 28 (03) : 367 - 375
  • [43] Specific Azimuth Self-Calibration of PIGA of Inertial Platform System
    Zhou Yuan
    Yan Lu
    Zhang Jinyun
    Yu Pei
    2015 IEEE 28TH CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2015, : 286 - 290
  • [44] Camera Self-Calibration for Unmarked Human Motion Capture System
    Wang, Jiaji
    Miao, Zhenjiang
    Liang, Qinghua
    Jiang, Ziling
    PROCEEDINGS OF 2018 14TH IEEE INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP), 2018, : 480 - 484
  • [45] Stage error calibration for coordinates measuring machines based on self-calibration algorithm
    Wang, Daodang
    Chen, Xixi
    Xu, Yangbo
    Guo, Tiantai
    Kong, Ming
    Zhao, Jun
    Zhang, Baowu
    Zhu, Baohua
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2015, 41 : 86 - 95
  • [46] A Self-Calibration of Leaky VNA System for In-Fixture Measurements
    Zbik, Mateusz
    Wiatr, Wojciech
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2023, 71 (11) : 4649 - 4657
  • [47] Hierarchical Time-of-Arrival Self-Calibration using Robust Receiver Distance Averaging
    Larsson, Malte
    Larsson, Viktor
    Olsson, Carl
    Oskarsson, Magnus
    32ND EUROPEAN SIGNAL PROCESSING CONFERENCE, EUSIPCO 2024, 2024, : 982 - 986
  • [48] An Amplitude-phase Measurement Method of Phased Array Antenna Based on Self-Calibration RF Channel
    Chen Tengbo
    Zhang Lu
    Du Hailong
    2018 10TH INTERNATIONAL CONFERENCE ON COMMUNICATION SOFTWARE AND NETWORKS (ICCSN), 2018, : 460 - 464
  • [49] Approach for Camera Self-Calibration Based on Five Straight Lines
    Qin, Lijuan
    Hu, Yulan
    Wei, Yingzi
    Zhou, Yue
    Wang, Hong
    2008 4TH INTERNATIONAL CONFERENCE ON WIRELESS COMMUNICATIONS, NETWORKING AND MOBILE COMPUTING, VOLS 1-31, 2008, : 10972 - 10975
  • [50] Self-calibration of micro-components based on manipulator guidance
    Yan, Hu
    Qin, Zhang
    Ciwen, Ma
    Zhiming, Ou
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2022, 32 (08)