Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement

被引:6
作者
Nguyen, Quoc Khanh [1 ,2 ]
Kim, Seungman [1 ]
Han, Seong-Heum [1 ]
Ro, Seung-Kook [1 ]
Kim, Seung-Woo [3 ]
Kim, Young-Jin [3 ]
Kim, Wooram [3 ]
Oh, Jeong Seok [1 ,2 ]
机构
[1] Korea Inst Machinery & Mat, Dept Ultraprecis Machines & Syst, Daejeon 34103, South Korea
[2] Univ Sci & Technol, Dept Nanomechatron, Daejeon 34113, South Korea
[3] Korea Adv Inst Sci & Technol, Dept Mech Engn, Daejeon 34141, South Korea
基金
新加坡国家研究基金会;
关键词
multilateration; self-calibration; absolute distance measurement; initial guess; TRACKING INTERFEROMETER SYSTEM; LARGE-SCALE METROLOGY; OF-FLIGHT MEASUREMENT; 3-DIMENSIONAL COORDINATE; LASER TRACKERS; ARRANGEMENT;
D O I
10.3390/s20247288
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multilateration tracking systems (MLTSs) are used in industrial three-dimensional (3D) coordinate measuring applications. For high-precision measurement, system parameters must be calibrated properly in advance. For an MLTS using absolute distance measurement (ADM), the conventional self-calibration method significantly reduces estimation efficiency because all system parameters are estimated simultaneously using a complicated residual function. This paper presents a novel self-calibration method that optimizes ADM to reduce the number of system parameters via highly precise and separate estimations of dead paths. Therefore, the residual function to estimate the tracking station locations can be simplified. By applying a suitable mathematical procedure and solving the initial guess problem without the aid of an external device, estimation accuracy of the system parameters is significantly improved. In three self-calibration experiments, with ADM repeatability of approximately 3.4 mu m, the maximum deviation of the system parameters estimated by the proposed self-calibration method was 68.6 mu m, while the maximum deviation estimated by the conventional self-calibration method was 711.9 mu m. Validation of 3D coordinate measurements in a 1000 mm x 1000 mm x 1000 mm volume showed good agreement between the proposed ADM-based MLTS and a commercial laser tracker, where the maximum difference based on the standard deviation was 17.7 mu m. Conversely, the maximum difference was 98.8 mu m using the conventional self-calibration method. These results confirmed the efficiency and feasibility of the proposed self-calibration method.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [31] An optimization of the Fourier self-calibration algorithm for improved noise suppression capability
    Peng, Yuqi
    Wu, Junjie
    Qiao, Xiaoyue
    Cai, Xiaoyu
    Wei, Jiasi
    Ding, Guoqing
    Wang, Kundong
    Chen, Xin
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2025, 36 (01)
  • [32] Self-calibration of projective camera based on trajectory basis
    Liu, Shigang
    Peng, Yali
    Sun, Zengguo
    Wang, Xili
    JOURNAL OF COMPUTATIONAL SCIENCE, 2019, 31 : 45 - 53
  • [33] Self-calibration of a vision-based sensor network
    Marinakis, Dimitri
    Dudek, Gregory
    IMAGE AND VISION COMPUTING, 2009, 27 (1-2) : 116 - 130
  • [34] Self-calibration method of precision shafting angle measurement error based on multiple reading heads
    Zhang, Run
    Bao, Wenhui
    Zhao, Huining
    Jia, Huakun
    Yu, Liandong
    TENTH INTERNATIONAL SYMPOSIUM ON PRECISION ENGINEERING MEASUREMENTS AND INSTRUMENTATION, 2019, 11053
  • [35] Self-calibration Method for Robot Based on Geometric Constraints
    Shi, Jingfei
    Zhang, Hongsheng
    Liu, Yuan
    Wang, Daqing
    Gao, Lifu
    2016 IEEE INTERNATIONAL CONFERENCE ON INFORMATION AND AUTOMATION (ICIA), 2016, : 1863 - 1867
  • [36] Point-specific self-calibration for improved characterization of thickness distribution
    Meng, Fangfang
    Chen, Kun
    Zhou, Tian
    Wu, Tao
    Wei, Haoyun
    Li, Yan
    OPTICAL ENGINEERING, 2016, 55 (08)
  • [37] A self-calibration rotational stitching method for precision measurement of revolving surfaces
    Liu, M. Y.
    Cheung, C. F.
    Feng, X.
    Wang, C. J.
    Leach, R. K.
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2018, 54 : 60 - 69
  • [38] An Optimization Self-calibration Method of Rotational Inertial Navigation System Based on Genetic Algorithm
    Ren, Qian
    Wang, Bo
    Deng, Zhihong
    Fu, Mengyin
    PROCEEDINGS 2013 INTERNATIONAL CONFERENCE ON MECHATRONIC SCIENCES, ELECTRIC ENGINEERING AND COMPUTER (MEC), 2013, : 2764 - 2767
  • [39] Self-calibration for linear structured light 3D measurement system based on quantum genetic algorithm and feature matching
    Pan, Xinjian
    Wu, Jieying
    Li, Zhili
    Yang, Jianjun
    Zhang, Chongfu
    Deng, Chunjian
    Yi, Zichuan
    Gao, Qingguo
    Yu, Miao
    Zhang, Zhi
    Liu, Liming
    Chi, Feng
    Bai, Pengfei
    OPTIK, 2021, 225
  • [40] Research on self-calibration biaxial autocollimator based on ZYNQ
    Guo, Pan
    Liu, Bingguo
    Liu, Guodong
    Zhong, Yao
    Lu, Binghui
    2017 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: OPTICAL SYSTEMS AND MODERN OPTOELECTRONIC INSTRUMENTS, 2017, 10616