Improved Self-Calibration of a Multilateration System Based on Absolute Distance Measurement

被引:6
|
作者
Nguyen, Quoc Khanh [1 ,2 ]
Kim, Seungman [1 ]
Han, Seong-Heum [1 ]
Ro, Seung-Kook [1 ]
Kim, Seung-Woo [3 ]
Kim, Young-Jin [3 ]
Kim, Wooram [3 ]
Oh, Jeong Seok [1 ,2 ]
机构
[1] Korea Inst Machinery & Mat, Dept Ultraprecis Machines & Syst, Daejeon 34103, South Korea
[2] Univ Sci & Technol, Dept Nanomechatron, Daejeon 34113, South Korea
[3] Korea Adv Inst Sci & Technol, Dept Mech Engn, Daejeon 34141, South Korea
基金
新加坡国家研究基金会;
关键词
multilateration; self-calibration; absolute distance measurement; initial guess; TRACKING INTERFEROMETER SYSTEM; LARGE-SCALE METROLOGY; OF-FLIGHT MEASUREMENT; 3-DIMENSIONAL COORDINATE; LASER TRACKERS; ARRANGEMENT;
D O I
10.3390/s20247288
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Multilateration tracking systems (MLTSs) are used in industrial three-dimensional (3D) coordinate measuring applications. For high-precision measurement, system parameters must be calibrated properly in advance. For an MLTS using absolute distance measurement (ADM), the conventional self-calibration method significantly reduces estimation efficiency because all system parameters are estimated simultaneously using a complicated residual function. This paper presents a novel self-calibration method that optimizes ADM to reduce the number of system parameters via highly precise and separate estimations of dead paths. Therefore, the residual function to estimate the tracking station locations can be simplified. By applying a suitable mathematical procedure and solving the initial guess problem without the aid of an external device, estimation accuracy of the system parameters is significantly improved. In three self-calibration experiments, with ADM repeatability of approximately 3.4 mu m, the maximum deviation of the system parameters estimated by the proposed self-calibration method was 68.6 mu m, while the maximum deviation estimated by the conventional self-calibration method was 711.9 mu m. Validation of 3D coordinate measurements in a 1000 mm x 1000 mm x 1000 mm volume showed good agreement between the proposed ADM-based MLTS and a commercial laser tracker, where the maximum difference based on the standard deviation was 17.7 mu m. Conversely, the maximum difference was 98.8 mu m using the conventional self-calibration method. These results confirmed the efficiency and feasibility of the proposed self-calibration method.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [21] A self-calibration method of non-contact voltage measurement based on impedance transformation
    Huang R.
    Suo C.
    Zhang W.
    Zhu J.
    Zou X.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2023, 44 (03): : 137 - 145
  • [22] Self-calibration for IGBT Junction Temperature Measurement in Power Converter
    Yuan, Yichao
    Xiang, Dawei
    Ning, Chen
    2016 IEEE 8TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE (IPEMC-ECCE ASIA), 2016,
  • [23] Frequency Scanning Interferometry Absolute Distance Measurement Method Based on Optical Spectrum Calibration
    Shang Yue
    Wu Tengfei
    Lin Jiarui
    Yang Linghui
    Zhou Qiang
    Zhu Jigui
    ACTA OPTICA SINICA, 2022, 42 (12)
  • [24] Self-calibration of a binocular vision system based on a one-dimensional target
    Zhao, Yu
    Li, Weimin
    JOURNAL OF MODERN OPTICS, 2014, 61 (18) : 1529 - 1537
  • [25] An Improved Fast Self-Calibration Method for Hybrid Inertial Navigation System under Stationary Condition
    Liu, Bingqi
    Wei, Shihui
    Su, Guohua
    Wang, Jiping
    Lu, Jiazhen
    SENSORS, 2018, 18 (05)
  • [26] Development and self-calibration of a robotic visual inspecting system
    Yu, Chengyi
    Chen, Xiaobo
    Xi, Juntong
    PROCEEDINGS OF THE 2017 2ND INTERNATIONAL CONFERENCE ON MACHINERY, ELECTRONICS AND CONTROL SIMULATION (MECS 2017), 2017, 138 : 1 - 8
  • [27] The Calibration Algorithms for Industrial Robots Based on a Novel Self-calibration Device
    Gu L.
    Yang G.
    Fang Z.
    Wang R.
    Zheng T.
    Jiqiren/Robot, 2020, 42 (01): : 100 - 109
  • [28] New optic fiber interferometer system for absolute distance measurement
    Duan, FJ
    Yang, B
    Ye, SH
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION SCIENCE AND TECHNOLOGY, VOL 1, 2002, : 517 - 520
  • [29] An optimization of the Fourier self-calibration algorithm for improved noise suppression capability
    Peng, Yuqi
    Wu, Junjie
    Qiao, Xiaoyue
    Cai, Xiaoyu
    Wei, Jiasi
    Ding, Guoqing
    Wang, Kundong
    Chen, Xin
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2025, 36 (01)
  • [30] Self-calibration of projective camera based on trajectory basis
    Liu, Shigang
    Peng, Yali
    Sun, Zengguo
    Wang, Xili
    JOURNAL OF COMPUTATIONAL SCIENCE, 2019, 31 : 45 - 53