DIAGNOSTIC PERFORMANCE OF ULTRASOUND SHEAR WAVE ELASTOGRAPHY IN SOLID SMALL (≤4 CM) RENAL PARENCHYMAL MASSES

被引:12
|
作者
Cai, Yingyu [1 ]
Li, Fan [1 ]
Li, Zhaojun [1 ]
Du, Lianfang [1 ]
Wu, Rong [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Ultrasound, Sch Med, 100 Haining Rd, Shanghai 200080, Peoples R China
关键词
Kidney neoplasms; Ultrasonography; Shear wave elastography; Differential diagnosis; Renal cell carcinoma; CONTRAST-ENHANCED ULTRASOUND; FORCE IMPULSE ELASTOGRAPHY; WFUMB GUIDELINES; CELL CARCINOMA; CLINICAL-USE; MINIMAL FAT; ANGIOMYOLIPOMA; KIDNEY; RECOMMENDATIONS; LESIONS;
D O I
10.1016/j.ultrasmedbio.2019.05.010
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of the study was to analyze the diagnostic performance of shear wave elastography (SWE) in differentiating between malignant and benign solid renal parenchymal masses <= 4 cm, compared with conventional ultrasound. A total of 20 healthy volunteers and 117 patients had been included in this study. Conventional ultrasound and SWE were performed in all volunteers and patients. The elasticity of healthy cortex and the elastic parameters of tumors such as mean elasticity (E-mean), minimum elasticity (E-min), maximum elasticity (E-max), standard deviation and elasticity ratio of the lesion to surrounding cortex (E-ratio) were measured on SWE images. Diagnostic performance of SWE was compared with that of conventional ultrasound. The cortical elasticity values of healthy right and left kidneys were 4.7 +/- 1.7 and 4.5 +/- 1.5 kPa, respectively. Of the 117 renal tumors, 68 were renal cell carcinomas (RCCs) and 49 were benign. E-mean, E-min and E-ratio were significantly lower in RCCs compared with benign lesions: E-mean 7.2 +/- 2.5 kPa versus 10.0 +/- 2.4 kPa, E-min 2.5 +/- 2.4 kPa versus 5.6 +/- 2.3 kPa, E-ratio 1.6 +/- 0.5 versus 2.2 +/- 0.6 (all p values < 0.001). The cutoff values of 9.15 kPa for E-mean, 3.55 kPa for E-min and 1.99 for E-ratio had the highest areas under the receiver operating characteristics curve (0.801 for E-mean, 0.832 for E-min and 0.806 for E-ratio). Combining E-mean, E-min and E-ratio with conventional ultrasound improved the specificity for predicting RCCs to 87.8%, but the sensitivity was not increased. (C) 2019 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:2328 / 2337
页数:10
相关论文
共 50 条
  • [41] INTRA-OBSERVER REPRODUCIBILITY AND DIAGNOSTIC PERFORMANCE OF BREAST SHEAR-WAVE ELASTOGRAPHY IN ASIAN WOMEN
    Park, Hye Young
    Han, Kyung Hwa
    Yoon, Jung Hyun
    Moon, Hee Jung
    Kim, Min Jung
    Kim, Eun-Kyung
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (06) : 1058 - 1064
  • [42] Quantitative assessment of shear-wave ultrasound elastography in thyroid nodules: diagnostic performance for predicting malignancy
    Hana Kim
    Jeong-Ah Kim
    Eun Ju Son
    Ji Hyun Youk
    European Radiology, 2013, 23 : 2532 - 2537
  • [43] Diagnostic performance of conventional ultrasound and quantitative and qualitative real-time shear wave elastography in musculoskeletal soft tissue tumors
    Li, Ao
    Peng, Xiao-Jing
    Ma, Qian
    Dong, Ye
    Mao, Cui-Lian
    Hu, Yu
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2020, 15 (01)
  • [44] The diagnostic value of ultrasound and shear wave elastography in the differentiation of benign and malignant soft tissue tumors
    Ozturk, Mesut
    Selcuk, Mustafa Bekir
    Polat, Ahmet Veysel
    Ozbalci, Aysu Basak
    Baris, Yakup Sancar
    SKELETAL RADIOLOGY, 2020, 49 (11) : 1795 - 1805
  • [45] Diagnostic value of contrast-enhanced ultrasound and shear-wave elastography for breast lesions of sub-centimeter
    Xiang, Li-Hua
    Yao, Ming-Hua
    Xu, Guang
    Pu, Huan
    Liu, Hui
    Fang, Yan
    Wu, Rong
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2017, 67 (01) : 69 - 80
  • [46] Diagnostic accuracy of shear wave elastography - Virtual touch™ imaging quantification in the evaluation of breast masses: Impact on ultrasonography's specificity and its ultimate clinical benefit
    Doria, Maira Teixeira
    Jales, Rodrigo Menezes
    Conz, Livia
    Mauricette Derchain, Sophie Francoise
    Zanatta Sarian, Luis Otavio
    EUROPEAN JOURNAL OF RADIOLOGY, 2019, 113 : 74 - 80
  • [47] Combination of shear wave elastography and BI-RADS in identification of solid breast masses
    Xue Zheng
    Fei Li
    Zhi-Dong Xuan
    Yu Wang
    Lei Zhang
    BMC Medical Imaging, 21
  • [48] Incremental diagnostic value of shear wave elastography combined with contrast-enhanced ultrasound in TI-RADS category 4a and 4b nodules
    Huang, Shao-Ting
    Zhang, Bo
    Yin, Hong-Ling
    Li, Bo
    Liao, Jin-Tang
    Wang, Yi-Bin
    JOURNAL OF MEDICAL ULTRASONICS, 2020, 47 (03) : 453 - 462
  • [49] Combination of shear wave elastography and BI-RADS in identification of solid breast masses
    Zheng, Xue
    Li, Fei
    Xuan, Zhi-Dong
    Wang, Yu
    Zhang, Lei
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [50] Diagnostic utility of renal shear wave elastography and renal Doppler findings in diabetic nephropathy: a case–control study
    Ahmed Abdelrahman Baz
    Eman Muhammad Abdeen
    Mona Yousry Helmy
    Abo El-Magd Al-Bohy
    Egyptian Journal of Radiology and Nuclear Medicine, 55