DIAGNOSTIC PERFORMANCE OF ULTRASOUND SHEAR WAVE ELASTOGRAPHY IN SOLID SMALL (≤4 CM) RENAL PARENCHYMAL MASSES

被引:12
|
作者
Cai, Yingyu [1 ]
Li, Fan [1 ]
Li, Zhaojun [1 ]
Du, Lianfang [1 ]
Wu, Rong [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Ultrasound, Sch Med, 100 Haining Rd, Shanghai 200080, Peoples R China
关键词
Kidney neoplasms; Ultrasonography; Shear wave elastography; Differential diagnosis; Renal cell carcinoma; CONTRAST-ENHANCED ULTRASOUND; FORCE IMPULSE ELASTOGRAPHY; WFUMB GUIDELINES; CELL CARCINOMA; CLINICAL-USE; MINIMAL FAT; ANGIOMYOLIPOMA; KIDNEY; RECOMMENDATIONS; LESIONS;
D O I
10.1016/j.ultrasmedbio.2019.05.010
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The aim of the study was to analyze the diagnostic performance of shear wave elastography (SWE) in differentiating between malignant and benign solid renal parenchymal masses <= 4 cm, compared with conventional ultrasound. A total of 20 healthy volunteers and 117 patients had been included in this study. Conventional ultrasound and SWE were performed in all volunteers and patients. The elasticity of healthy cortex and the elastic parameters of tumors such as mean elasticity (E-mean), minimum elasticity (E-min), maximum elasticity (E-max), standard deviation and elasticity ratio of the lesion to surrounding cortex (E-ratio) were measured on SWE images. Diagnostic performance of SWE was compared with that of conventional ultrasound. The cortical elasticity values of healthy right and left kidneys were 4.7 +/- 1.7 and 4.5 +/- 1.5 kPa, respectively. Of the 117 renal tumors, 68 were renal cell carcinomas (RCCs) and 49 were benign. E-mean, E-min and E-ratio were significantly lower in RCCs compared with benign lesions: E-mean 7.2 +/- 2.5 kPa versus 10.0 +/- 2.4 kPa, E-min 2.5 +/- 2.4 kPa versus 5.6 +/- 2.3 kPa, E-ratio 1.6 +/- 0.5 versus 2.2 +/- 0.6 (all p values < 0.001). The cutoff values of 9.15 kPa for E-mean, 3.55 kPa for E-min and 1.99 for E-ratio had the highest areas under the receiver operating characteristics curve (0.801 for E-mean, 0.832 for E-min and 0.806 for E-ratio). Combining E-mean, E-min and E-ratio with conventional ultrasound improved the specificity for predicting RCCs to 87.8%, but the sensitivity was not increased. (C) 2019 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:2328 / 2337
页数:10
相关论文
共 50 条
  • [21] Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?
    Lee, Eun Jung
    Jung, Hae Kyoung
    Ko, Kyung Hee
    Lee, Jong Tae
    Yoon, Jung Hyun
    EUROPEAN RADIOLOGY, 2013, 23 (07) : 1803 - 1811
  • [22] Usability of Transthoracic Shear Wave Elastography in Differentiation of Subpleural Solid Masses
    Ozgokce, Mesut
    Yavuz, Alpaslan
    Akbudak, Ibrahim
    Durmaz, Fatma
    Uney, Ibrahim
    Aydin, Yener
    Yildiz, Hanifi
    Batur, Abdussamet
    Arslan, Harun
    Dundar, Ilyas
    ULTRASOUND QUARTERLY, 2018, 34 (04) : 233 - 237
  • [23] Performance Assessment of Motion Tracking Methods in Ultrasound-based Shear Wave Elastography
    He, Tingting
    Peng, Bo
    Chen, Pengcheng
    Jiang, Jingfeng
    2020 IEEE INTERNATIONAL CONFERENCE ON SYSTEMS, MAN, AND CYBERNETICS (SMC), 2020, : 3643 - 3648
  • [24] Differentiation of Small (≤ 4 cm) Renal Masses on Multiphase Contrast-Enhanced CT by Deep Learning
    Tanaka, Takashi
    Huang, Yong
    Marukawa, Yohei
    Tsuboi, Yuka
    Masaoka, Yoshihisa
    Kojima, Katsuhide
    Iguchi, Toshihiro
    Hiraki, Takao
    Gobara, Hideo
    Yanai, Hiroyuki
    Nasu, Yasutomo
    Kanazawa, Susumu
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (03) : 605 - 612
  • [25] Diagnostic Performance of Shear Wave Elastography of the Breast According to Scanning Orientation
    Kim, Solip
    Choi, SeonHyeong
    Choi, Yoonjung
    Kook, Shin-Ho
    Park, Hee Jin
    Chung, Eun Chul
    JOURNAL OF ULTRASOUND IN MEDICINE, 2014, 33 (10) : 1797 - 1804
  • [26] Are growth patterns on MRI in small (< 4 cm) solid renal masses useful for predicting benign histology?
    Robert S. Lim
    Matthew D. F. McInnes
    Mahadevaswamy Siddaiah
    Trevor A. Flood
    Luke T. Lavallee
    Nicola Schieda
    European Radiology, 2018, 28 : 3115 - 3124
  • [27] Comparison of the Diagnostic Performance of Strain Elastography and Shear Wave Elastography for the Diagnosis of Carpal Tunnel Syndrome
    Park, Eun Joo
    Hahn, Seok
    Yi, Jisook
    Shin, Kyong Jin
    Lee, Yedaun
    Lee, Ho-Joon
    JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (05) : 1011 - 1021
  • [28] Shear Wave Elastography: Is It a Valuable Additive Method to Conventional Ultrasound for the Diagnosis of Small (≤2 cm) Breast Cancer?
    Kim, So Jung
    Ko, Kyung Hee
    Jung, Hae Kyoung
    Kim, Hyerin
    MEDICINE, 2015, 94 (42) : e1540
  • [29] Diagnostic utility of strain and shear wave ultrasound elastography in differentiation of benign and malignant solid breast lesions
    Ahmed Tohamy Ahmed
    Egyptian Journal of Radiology and Nuclear Medicine, 51
  • [30] SHEAR WAVE ELASTOGRAPHY OF BREAST LESIONS: QUANTITATIVE ANALYSIS OF ELASTIC HETEROGENEITY IMPROVES DIAGNOSTIC PERFORMANCE
    Huang, Yini
    Li, Fei
    Han, Jing
    Peng, Chuan
    Li, Qing
    Cao, Longhui
    Liu, Yubo
    Zhou, Jianhua
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (08) : 1909 - 1917