Allergic Contact Dermatitis to Dermabond Prineo After Elective Orthopedic Surgery

被引:18
作者
Ricciardo, Bernadette M. [1 ]
Nixon, Rosemary L. [4 ]
Tam, Mei Mui [4 ]
Radic, Ross R. [3 ]
Ricciardo, Brendan J. [2 ]
机构
[1] Fiona Stanley Hosp, Dept Dermatol, 11 Robin Warren Dr, Murdoch, WA 6150, Australia
[2] Fiona Stanley Hosp, Dept Orthopaed Surg, Murdoch, WA, Australia
[3] Perth Orthopaed & Sports Med Ctr, Perth, WA, Australia
[4] Skin Hlth Inst, Melbourne, Vic, Australia
关键词
2-OCTYL CYANOACRYLATE; WOUND CLOSURE; DEVICE;
D O I
10.3928/01477447-20200827-01
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The Dermabond Prineo skin closure system (Ethicon, Somerville, New Jersey) is a wound closure device that combines a 2-octyl cyanoacrylate liquid adhesive and a self-adhesive polyester mesh. Although cyanoacrylates traditionally have been associated with low rates of sensitization, allergic contact dermatitis (ACD) to Dermabond products is being increasingly reported after orthopedic surgery. The authors describe the first case series of ACD to Dermabond Prineo where patch testing confirmed the diagnosis in all patients. Six patients who had suspected Dermabond Prineo ACD after lower limb orthopedic surgery were assessed. Of these patients, 5 had itching within 4 days of surgery and rash within 5 days. All 5 of these patients reported previous exposure to Dermabond products. All patients had removal of the adhesive and mesh earlier than planned and were treated with corticosteroids. In addition, 4 patients received systemic antibiotics; however, only 1 had a microbiologically confirmed superficial skin infection. In all patients,the dermatitis resolved within 2 weeks of dressing removal, with no adverse effect on the orthopedic outcome. Patch testing showed positive reactions to Dermabond Prineo glue for all patients. Orthopedic surgeons should beaware of the potential for ACD to Dermabond Prineo, especially among patients with previous exposure to Dermabond products. The authors discuss the risk factors for ACD to Dermabond Prineo in the orthopedic cohort and provide recommendations for prevention and management.
引用
收藏
页码:E515 / E522
页数:8
相关论文
共 25 条
[11]   Allergic Contact Dermatitis to Dermabond (2-Octyl Cyanoacrylate) After Total Knee Arthroplasty [J].
Durando, Dunnett ;
Porubsky, Caitlin ;
Winter, Suzanne ;
Kalymon, JoEllen ;
O'Keefe, Thomas ;
LaFond, Ann Ammond .
DERMATITIS, 2014, 25 (02) :99-100
[12]   Allergic contact dermatitis to Dermabond® after orthopaedic joint replacement [J].
El-Dars, L. D. ;
Chaudhury, W. ;
Hughes, T. M. ;
Stone, N. M. .
CONTACT DERMATITIS, 2010, 62 (05) :315-317
[13]   Surgical Treatment of Early Wound Complications Following Primary Total Knee Arthroplasty [J].
Galat, Daniel D. ;
McGovern, Scott C. ;
Larson, Dirk R. ;
Harrington, Jeffrey R. ;
Hanssen, Arlen D. ;
Clarke, Henry D. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (01) :48-54
[14]   Allergic contact dermatitis after postsurgical repair with 2-octylcyanoacrylate [J].
Hivnor, Chad M. ;
Hudkins, Matthew L. .
ARCHIVES OF DERMATOLOGY, 2008, 144 (06) :814-815
[15]   Effective Wound Closure With a New Two-Component Wound Closure Device (Prineo™) in Excisional Body-Contouring Surgery: Experience in Over 200 Procedures [J].
Huemer, Georg M. ;
Schmidt, Manfred ;
Helml, Gudrun H. ;
Shafighi, Maziar ;
Dunst-Huemer, Karin M. .
AESTHETIC PLASTIC SURGERY, 2012, 36 (02) :382-386
[16]   Procrastination of wound drainage and malnutrition affect the outcome of joint arthroplasty [J].
Jaberi, Fereidoon M. ;
Parvizi, Javad ;
Haytmanek, C. Thomas ;
Joshi, Ashish ;
Purtill, James .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (06) :1368-1371
[17]   Rash with DERMABOND PRINEO Skin Closure System Use in Bilateral Reduction Mammoplasty: A Case Series [J].
Knackstedt, R. W. ;
Dixon, J. A. ;
O'Neill, P. J. ;
Herrera, F. A. .
CASE REPORTS IN MEDICINE, 2015, 2015
[18]   Contact Dermatitis Reaction to 2-Octyl Cyanoacrylate Following 3 Orthopedic Procedures [J].
Lake, Nicholas H. ;
Barlow, Brian T. ;
Toledano, James E. ;
Valentine, Johannah ;
McDonald, Lucas S. .
ORTHOPEDICS, 2018, 41 (02) :E289-E291
[19]   Utility of scratch tests for allergic contact dermatitis caused by Dermabond [J].
Lefevre, Sebastien ;
Valois, Aude ;
Truchetet, Francois .
CONTACT DERMATITIS, 2017, 76 (03) :193-194
[20]   Allergic contact dermatitis caused by Dermabond® [J].
Lefevre, Sebastien ;
Valois, Aude ;
Truchetet, Francois .
CONTACT DERMATITIS, 2016, 75 (04) :240-+