Wearable Cardioverter-Defibrillator Therapy for the Prevention of Sudden Cardiac Death A Systematic Review and Meta-Analysis

被引:46
作者
Masri, Ahmad [1 ]
Altibi, Ahmed M. [1 ]
Erqou, Sebhat [2 ,3 ]
Zmaili, Mohammad A. [1 ]
Saleh, Ala [1 ]
Al-Adham, Raed [4 ]
Ayoub, Karam [5 ]
Baghal, Moaaz [1 ]
Alkukhun, Laith [1 ]
Barakat, Amr F. [1 ]
Jain, Sandeep [1 ]
Saba, Samir [1 ]
Adelstein, Evan [6 ]
机构
[1] Univ Pittsburgh, Med Ctr, Heart & Vasc Inst, Pittsburgh, PA 15213 USA
[2] Brown Univ, Dept Med, Providence VA Med Ctr, Providence, RI 02912 USA
[3] Brown Univ, Alpert Med Sch, Providence, RI 02912 USA
[4] Univ Arizona, Dept Med, Phoenix, AZ USA
[5] Univ Kentucky, Dept Med, Div Cardiol, Lexington, KY USA
[6] Albany Med Coll, Div Cardiol, Albany, NY USA
基金
美国国家卫生研究院;
关键词
death; meta-analysis; shock; systematic review; wearable cardioverter-defibrillator; HIGH-RISK; NATIONAL EXPERIENCE; CARDIOMYOPATHY; IMPLANTATION; PERIPARTUM; PHASE;
D O I
10.1016/j.jacep.2018.11.011
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to synthesize the available evidence on the use of the wearable cardioverter-defibrillator (WCD). BACKGROUND Observational WCD studies for the prevention of sudden cardiac death have provided conflicting data. The VEST (Vest Prevention of Early Sudden Death) trial was the first randomized controlled trial (RCT) showing no reduction in sudden cardiac death as compared to medical therapy only. METHODS We searched PubMed, EMBASE, and Google Scholar for studies reporting on the outcomes of patients wearing WCDs from January 1, 2001, through March 20, 2018. Rates of appropriate and inappropriate WCD therapies were pooled. Estimates were derived using DerSimonian and Laird's method. RESULTS Twenty-eight studies were included (N = 33,242; 27 observational, 1 RCT-WCD arm). The incidence of appropriate WCD therapy was 5 per 100 persons over 3 months (95% confidence interval [CI]: 3.0 to 6.0, I-2 = 93%). In studies on ischemic cardiomyopathy, the appropriate WCD therapy incidence was lower in the VEST trial (1 per 100 persons over 3 months; 95% CI: 1.0 to 2.0) as compared with observational studies (11 per 100 persons over 3 months; 95% CI: 11.0 to 20.0; I-2 = 93%). The incidence of inappropriate therapy was 2 per 100 persons over 3 months (95% CI: 1.0 to 3.0; I-2 = 93%). Mortality while wearing WCD was rare at 0.7 per 100 persons over 3 months (95% CI: 0.3 to 1.7; I-2 = 94%). CONCLUSIONS The rate of appropriately treated WCD patients over 3 months of follow-up was substantial; higher in-observational studies as compared with the VEST trial. There was significant heterogeneity. More RCTs are needed to justify continued use of WCD in primary prevention. (C) 2019 by the American College of Cardiology Foundation.
引用
收藏
页码:152 / 161
页数:10
相关论文
共 35 条
[1]  
Al-Khatib SM, 2018, CIRCULATION, V138, pE210, DOI [10.1161/CIR.0000000000000548, 10.1161/CIR.0000000000000549]
[2]   Ventricular Arrhythmia Occurrence and Compliance in Patients Treated With the Wearable Cardioverter Defibrillator Following Percutaneous Coronary Intervention [J].
Barraud, Jeremie ;
Pinon, Pauline ;
Laine, Marc ;
Cautela, Jennifer ;
Orabona, Morgane ;
Koutbi, Linda ;
Pinto, Johan ;
Thuny, Franck ;
Franceschi, Frederic ;
Paganelli, Franck ;
Bonello, Laurent ;
Peyrol, Michael .
HEART LUNG AND CIRCULATION, 2018, 27 (08) :984-988
[3]   Study of the wearable cardioverter defibrillator in advanced heart-failure patients (SWIFT) [J].
Barsheshet, Alon ;
Kutyifa, Valentina ;
Vamvouris, Theodora ;
Moss, Arthur J. ;
Biton, Yitschak ;
Chen, Leway ;
Storozynsky, Eugene ;
Wan, Chingping ;
Szymkiewicz, Steven J. ;
Goldenberg, Ilan .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (07) :778-784
[4]   A real world wearable cardioverter defibrillator experience - Very high appropriate shock rate in ischemic cardiomyopathy patients at a European single-center [J].
Beiert, Thomas ;
Malotki, Robert ;
Kraemer, Natalie ;
Stoeckigt, Florian ;
Linhart, Markus ;
Nickenig, Georg ;
Schrickel, Jan W. ;
Andrie, Rene P. .
JOURNAL OF ELECTROCARDIOLOGY, 2017, 50 (05) :603-609
[5]   The Wearable Cardioverter Defibrillator: an Early Single Centre Australian Experience. Some Pitfalls and Caveats for Use [J].
Bhaskaran, Abhishek ;
Bartlett, Monique ;
Kovoor, Pramesh ;
Davis, Lloyd M. .
HEART LUNG AND CIRCULATION, 2016, 25 (02) :155-159
[6]   Aggregate National Experience With the Wearable Cardioverter-Defibrillator Event Rates, Compliance, and Survival [J].
Chung, Mina K. ;
Szymkiewicz, Steven J. ;
Shao, Mingyuan ;
Zishiri, Edwin ;
Niebauer, Mark J. ;
Lindsay, Bruce D. ;
Tchou, Patrick J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 56 (03) :194-203
[7]   METAANALYSIS IN CLINICAL-TRIALS [J].
DERSIMONIAN, R ;
LAIRD, N .
CONTROLLED CLINICAL TRIALS, 1986, 7 (03) :177-188
[8]   Ventricular arrhythmias in patients with newly diagnosed nonischemic cardiomyopathy: Insights from the PROLONG study [J].
Duncker, David ;
Koenig, Thorben ;
Hohmann, Stephan ;
Bauersachs, Johann ;
Veltmann, Christian .
CLINICAL CARDIOLOGY, 2017, 40 (08) :586-590
[9]   Risk for life-threatening arrhythmia in newly diagnosed peripartum cardiomyopathy with low ejection fraction: a German multi-centre analysis [J].
Duncker, David ;
Westenfeld, Ralf ;
Konrad, Torsten ;
Pfeffer, Tobias ;
de Freitas, Carlos A. Correia ;
Pfister, Roman ;
Thomas, Dierk ;
Fuernkranz, Alexander ;
Andrie, Rene P. ;
Napp, Andreas ;
Schmitt, Joern ;
Karolyi, Laszlo ;
Wakili, Reza ;
Hilfiker-Kleiner, Denise ;
Bauersachs, Johann ;
Veltmann, Christian .
CLINICAL RESEARCH IN CARDIOLOGY, 2017, 106 (08) :582-589
[10]   Bias in meta-analysis detected by a simple, graphical test [J].
Egger, M ;
Smith, GD ;
Schneider, M ;
Minder, C .
BMJ-BRITISH MEDICAL JOURNAL, 1997, 315 (7109) :629-634