Rapid quantification of kinematical viscosity in aviation kerosene by near-infrared spectroscopy

被引:9
作者
Xing, Zhi-na [1 ]
Wang, Ju-xiang [1 ]
Ye, Yong [1 ]
Shen, Gang [1 ]
机构
[1] Naval Aeronaut Engn Inst, Dept Aerocraft Engn, Yantai 264001, Shandong, Peoples R China
关键词
D O I
10.1021/ef060003i
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A quantitative near-infrared spectroscopy (NIRS) method was developed for the determination of the kinematical viscosity of aviation kerosene in terms of chemometrics. Reference measurement was performed by ASTM445. The calibration model of aviation kerosene was established by partial least-squares (PLS) regression. Satisfactory calibration statistics were obtained with a standard error of calibration (SEC) of 0.012 mm(2)/s and a standard error of prediction (SEP) of 0.027 mm(2)/s. A t-test showed that the NIRS model had an accuracy equivalent to that of ASTM445 in the analysis of the kinematical viscosity of aviation kerosene. The study emphasized the potential of NIRS as a rapid and highly effective alternative analysis method to the conventional quantitative analysis of kinematical viscosity of aviation kerosene.
引用
收藏
页码:2486 / 2488
页数:3
相关论文
共 6 条
  • [1] LU WZ, 2000, MODERN NIRS ANAL TEC, V4, P146
  • [2] Michael D. J., 2004, TALANTA, V62, P675
  • [3] DETERMINATION OF BODY-FAT AND MOISTURE IN DWARF HENS WITH NEAR-INFRARED REFLECTANCE SPECTROSCOPY
    RENDEN, JA
    OATES, SS
    REED, RB
    [J]. POULTRY SCIENCE, 1986, 65 (08) : 1539 - 1541
  • [4] SKOOG DA, 1998, PRINCIPLES INSTRUMEN, P422
  • [5] VOGELSANGER B, 2000, P 31 INT ANN C ICT K, P5
  • [6] WILLIAMS PC, 1988, CEREAL CHEM, V65, P109