A Precision System for Computed Tomography-Guided Needle Placement in the Thorax and Abdomen-Technical Design and Performance Analysis

被引:1
作者
Arnolli, Maarten M. [1 ,2 ]
Buijze, Martijn [1 ]
Franken, Michel [1 ]
Broeders, Ivo A. M. J. [3 ]
Brouwer, Dannis M. [2 ]
机构
[1] DEMCON Adv Mechatron, NL-7521 PH Enschede, Netherlands
[2] Univ Twente, Precis Engn Sci Based Engn, NL-7522 NB Enschede, Netherlands
[3] Univ Twente, Robot & Mechatron, MIRA Inst Biomed Technol & Tech Med, NL-7522 NB Enschede, Netherlands
来源
JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME | 2018年 / 12卷 / 02期
关键词
D O I
10.1115/1.4039389
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A system was developed for computed tomography (CT)-guided needle placement in the thorax and abdomen, providing precise aiming of a needle guide (NG) to reach a user-specified target in a single manual insertion. The objective of this work is to present its technical design and analyze its performance in terms of placement error in air. The individual contributions to the placement error of a fiducial marker based system-to-CT registration system, a two degrees-of-freedom (2DOFs) drive system to aim the NG, and a structural link between NG and CT table were experimentally determined, in addition to the placement error of the overall system. An error contribution of 0.81 +/- 0.34 mm was determined for the registration system, <1.2 mm and <3.3 mm for the drive system, and 0.35 mm and 0.43 mm for two load cases of the structural link. The overall unloaded system achieved 1.0 +/- 0.25 mm and 2.6 +/- 0.7 mm at 100 mm and 250 mm depth, respectively. The overall placement errors in air do not exceed the <= 5 mm error specified as a clinical user requirement for needle placement in tissue.
引用
收藏
页数:10
相关论文
共 11 条
  • [1] An overview of systems for CT- and MRI-guided percutaneous needle placement in the thorax and abdomen
    Arnolli, Maarten M.
    Hanumara, Nevan C.
    Franken, Michel
    Brouwer, Dannis M.
    Broeders, Ivo A. M. J.
    [J]. INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2015, 11 (04) : 458 - 475
  • [2] CT Registration: Experimental Determination of Suited Fiducial Marker Material and Registration Errors
    Arnolli, Maarten M.
    Franken, Michel
    Brouwer, Dannis M.
    [J]. JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2013, 7 (02):
  • [3] Barrett S., 2005, DETC200585387 ASME
  • [4] DEMCON, 2015, PREC NEEDL POS
  • [5] Dupuy Damian E, 2010, Semin Intervent Radiol, V27, P268, DOI 10.1055/s-0030-1261785
  • [6] McCarley James R, 2010, Semin Intervent Radiol, V27, P255, DOI 10.1055/s-0030-1261783
  • [7] Melzer A, 2003, RADIOLOGY S, V226, P409
  • [8] Patch D, 2011, SHERLOCK'S DISEASES OF THE LIVER AND BILIARY SYSTEM, 12TH EDITION, P36
  • [9] Sprawls P., 1995, Physical Principles of Medical Imaging
  • [10] AcuBot: A robot for radiological interventions
    Stoianovici, D
    Cleary, K
    Patriciu, A
    Mazilu, D
    Stanimir, A
    Craciunoiu, N
    Watson, V
    Kavoussi, L
    [J]. IEEE TRANSACTIONS ON ROBOTICS AND AUTOMATION, 2003, 19 (05): : 927 - 930