Simulated Radiation Dose Reduction in Whole-Body CT on a 3rd Generation Dual-Source Scanner: An Intraindividual Comparison

被引:6
|
作者
Brendlin, Andreas S. [1 ]
Winkelmann, Moritz T. [1 ]
Do, Phuong Linh [2 ]
Schwarze, Vincent [3 ]
Peisen, Felix [1 ]
Almansour, Haidara [1 ]
Bongers, Malte N. [1 ]
Artzner, Christoph P. [1 ]
Weiss, Jakob [4 ]
Kim, Jong Hyo [5 ,6 ]
Othman, Ahmed E. [1 ]
Afat, Saif [1 ]
机构
[1] Univ Hosp Tuebingen, Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[2] St Gertrauden Hosp Berlin, Dept Cardiol, D-10713 Berlin, Germany
[3] Univ Hosp LMU, Dept Radiol, D-80336 Munich, Germany
[4] Univ Hosp Freiburg, Dept Diagnost & Intervent Radiol, D-79106 Freiburg, Germany
[5] Seoul Natl Univ, Dept Radiol, Coll Med, Seoul 03080, South Korea
[6] Adv Inst Convergence Technol, Suwon 16229, South Korea
关键词
CT; whole-body staging; radiation dose; 3rd generation dual-source scanner; iterative reconstruction (IR); Filtered Back Projection (FBP); Advanced Modeled Iterative Reconstruction (ADMIRE); image reconstruction; MODELED ITERATIVE RECONSTRUCTION; TUBE VOLTAGE SELECTION; IMAGE QUALITY; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; ANGIOGRAPHY; ALGORITHM; RISK;
D O I
10.3390/diagnostics11010118
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the effect of radiation dose reduction on image quality and diagnostic confidence in contrast-enhanced whole-body computed tomography (WBCT) staging. We randomly selected March 2016 for retrospective inclusion of 18 consecutive patients (14 female, 60 +/- 15 years) with clinically indicated WBCT staging on the same 3rd generation dual-source CT. Using low-dose simulations, we created data sets with 100, 80, 60, 40, and 20% of the original radiation dose. Each set was reconstructed using filtered back projection (FBP) and Advanced Modeled Iterative Reconstruction (ADMIRE(R), Siemens Healthineers, Forchheim, Germany) strength 1-5, resulting in 540 datasets total. ADMIRE 2 was the reference standard for intraindividual comparison. The effective radiation dose was calculated using commercially available software. For comparison of objective image quality, noise assessments of subcutaneous adipose tissue regions were performed automatically using the software. Three radiologists blinded to the study evaluated image quality and diagnostic confidence independently on an equidistant 5-point Likert scale (1 = poor to 5 = excellent). At 100%, the effective radiation dose in our population was 13.3 +/- 9.1 mSv. At 20% radiation dose, it was possible to obtain comparably low noise levels when using ADMIRE 5 (p = 1.000, r = 0.29). We identified ADMIRE 3 at 40% radiation dose (5.3 +/- 3.6 mSv) as the lowest achievable radiation dose with image quality and diagnostic confidence equal to our reference standard (p = 1.000, r > 0.4). The inter-rater agreement for this result was almost perfect (ICC >= 0.958, 95% CI 0.909-0.983). On a 3rd generation scanner, it is feasible to maintain good subjective image quality, diagnostic confidence, and image noise in single-energy WBCT staging at dose levels as low as 40% of the original dose (5.3 +/- 3.6 mSv), when using ADMIRE 3.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Retrospective versus prospective ECG-gated dual-source CT in pediatric patients with congenital heart diseases: comparison of image quality and radiation dose
    Jin, Kwang Nam
    Park, Eun-Ah
    Shin, Cheong-Il
    Lee, Whal
    Chung, Jin Wook
    Park, Jae Hyung
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 : 63 - 73
  • [42] Improved visual delineation of the intimal flap in Stanford type A and B dissections at 3rd generation dual-source high-pitch CT angiography
    Beeres, Martin
    Bucher, Andreas M.
    Wichmann, Julian L.
    Frellesen, Claudia
    Scholtz, Jan E.
    Albrecht, Moritz
    Bodelle, Boris
    Nour-Eldin, Nour-Eldin A.
    Lee, Clara
    Kaup, Moritz
    Vogl, Thomas J.
    Gruber-Rouh, Tatjana
    RADIOLOGIA MEDICA, 2016, 121 (07): : 573 - 579
  • [43] Radiation dose and image quality of high-pitch emergency abdominal CT in obese patients using third-generation dual-source CT (DSCT)
    Forbrig, Robert
    Ingrisch, Michael
    Stahl, Robert
    Winter, Katharina Stella
    Reiser, Maximilian
    Trumm, Christoph G.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [44] Efficacy of a dynamic collimator for overranging dose reduction in a second- and third-generation dual source CT scanner
    Booij, Ronald
    Dijkshoorn, Marcel L.
    van Straten, Marcel
    EUROPEAN RADIOLOGY, 2017, 27 (09) : 3618 - 3624
  • [45] Whole Body Low Dose Computed Tomography Using Third-Generation Dual-Source Multidetector With Spectral Shaping: Protocol Optimization and Literature Review
    Baldi, Dario
    Tramontano, Liberatore
    Alfano, Vincenzo
    Punzo, Bruna
    Cavaliere, Carlo
    Salvatore, Marco
    DOSE-RESPONSE, 2020, 18 (04):
  • [46] Comparison of Chest Pain Protocols for Electrocardiography-Gated Dual-Source Cardiothoracic CT in Children and Adults: The Effect of Tube Current Saturation on Radiation Dose Reduction
    Goo, Hyun Woo
    KOREAN JOURNAL OF RADIOLOGY, 2018, 19 (01) : 23 - 31
  • [47] Dosimetric comparison of three different cardiac CT angiography techniques in a dual-source scanner using size-specific dose estimation (SSDE)
    Robatjazi, Mostafa
    Alizadeh, Navid Sarmast
    Molazadeh, Mikaeil
    Shokoohy, Fatemeh
    Javadinia, Seyed Alireza
    Dareyni, Amir
    Mosavi, Maryam
    RADIATION PHYSICS AND CHEMISTRY, 2025, 232
  • [48] Advantages and disadvantages of single-source dual-energy whole-body CT angiography with 50% reduced iodine dose at 40 keV reconstruction
    Noda, Yoshifumi
    Nakamura, Fumihiko
    Yasuda, Noriyuki
    Miyoshi, Toshiharu
    Kawai, Nobuyuki
    Kawada, Hiroshi
    Hyodo, Fuminori
    Matsuo, Masayuki
    BRITISH JOURNAL OF RADIOLOGY, 2021, 94 (1121)
  • [49] Quantification of left and right ventricular function and myocardial mass: Comparison of low-radiation dose 2nd generation dual-source CT and cardiac MRI
    Takx, Richard A. P.
    Moscariello, Antonio
    Schoepf, U. Joseph
    Barraza, J. Michael, Jr.
    Nance, John W., Jr.
    Bastarrika, Gorka
    Das, Marco
    Meyer, Mathias
    Wildberger, Joachim E.
    Schoenberg, Stefan O.
    Fink, Christian
    Henzler, Thomas
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) : E598 - E604
  • [50] Very Low-Dose (0.15 mGy) Chest CT Protocols Using the COPDGene 2 Test Object and a Third-Generation Dual-Source CT Scanner With Corresponding Third-Generation Iterative Reconstruction Software
    Newell, John D., Jr.
    Fuld, Matthew K.
    Allmendinger, Thomas
    Sieren, Jered P.
    Chan, Kung-Sik
    Guo, Junfeng
    Hoffman, Eric A.
    INVESTIGATIVE RADIOLOGY, 2015, 50 (01) : 40 - 45