Simulated Radiation Dose Reduction in Whole-Body CT on a 3rd Generation Dual-Source Scanner: An Intraindividual Comparison

被引:6
|
作者
Brendlin, Andreas S. [1 ]
Winkelmann, Moritz T. [1 ]
Do, Phuong Linh [2 ]
Schwarze, Vincent [3 ]
Peisen, Felix [1 ]
Almansour, Haidara [1 ]
Bongers, Malte N. [1 ]
Artzner, Christoph P. [1 ]
Weiss, Jakob [4 ]
Kim, Jong Hyo [5 ,6 ]
Othman, Ahmed E. [1 ]
Afat, Saif [1 ]
机构
[1] Univ Hosp Tuebingen, Dept Diagnost & Intervent Radiol, D-72076 Tubingen, Germany
[2] St Gertrauden Hosp Berlin, Dept Cardiol, D-10713 Berlin, Germany
[3] Univ Hosp LMU, Dept Radiol, D-80336 Munich, Germany
[4] Univ Hosp Freiburg, Dept Diagnost & Intervent Radiol, D-79106 Freiburg, Germany
[5] Seoul Natl Univ, Dept Radiol, Coll Med, Seoul 03080, South Korea
[6] Adv Inst Convergence Technol, Suwon 16229, South Korea
关键词
CT; whole-body staging; radiation dose; 3rd generation dual-source scanner; iterative reconstruction (IR); Filtered Back Projection (FBP); Advanced Modeled Iterative Reconstruction (ADMIRE); image reconstruction; MODELED ITERATIVE RECONSTRUCTION; TUBE VOLTAGE SELECTION; IMAGE QUALITY; COMPUTED-TOMOGRAPHY; DIAGNOSTIC-ACCURACY; ANGIOGRAPHY; ALGORITHM; RISK;
D O I
10.3390/diagnostics11010118
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the effect of radiation dose reduction on image quality and diagnostic confidence in contrast-enhanced whole-body computed tomography (WBCT) staging. We randomly selected March 2016 for retrospective inclusion of 18 consecutive patients (14 female, 60 +/- 15 years) with clinically indicated WBCT staging on the same 3rd generation dual-source CT. Using low-dose simulations, we created data sets with 100, 80, 60, 40, and 20% of the original radiation dose. Each set was reconstructed using filtered back projection (FBP) and Advanced Modeled Iterative Reconstruction (ADMIRE(R), Siemens Healthineers, Forchheim, Germany) strength 1-5, resulting in 540 datasets total. ADMIRE 2 was the reference standard for intraindividual comparison. The effective radiation dose was calculated using commercially available software. For comparison of objective image quality, noise assessments of subcutaneous adipose tissue regions were performed automatically using the software. Three radiologists blinded to the study evaluated image quality and diagnostic confidence independently on an equidistant 5-point Likert scale (1 = poor to 5 = excellent). At 100%, the effective radiation dose in our population was 13.3 +/- 9.1 mSv. At 20% radiation dose, it was possible to obtain comparably low noise levels when using ADMIRE 5 (p = 1.000, r = 0.29). We identified ADMIRE 3 at 40% radiation dose (5.3 +/- 3.6 mSv) as the lowest achievable radiation dose with image quality and diagnostic confidence equal to our reference standard (p = 1.000, r > 0.4). The inter-rater agreement for this result was almost perfect (ICC >= 0.958, 95% CI 0.909-0.983). On a 3rd generation scanner, it is feasible to maintain good subjective image quality, diagnostic confidence, and image noise in single-energy WBCT staging at dose levels as low as 40% of the original dose (5.3 +/- 3.6 mSv), when using ADMIRE 3.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Single- and dual-energy CT pulmonary angiography using second- and third-generation dual-source CT systems: comparison of radiation dose and image quality
    Lenga, Lukas
    Trapp, Franziska
    Albrecht, Moritz H.
    Wichmann, Julian L.
    Johnson, Addison A.
    Yel, Ibrahim
    D'Angelo, Tommaso
    Booz, Christian
    Vogl, Thomas J.
    Martin, Simon S.
    EUROPEAN RADIOLOGY, 2019, 29 (09) : 4603 - 4612
  • [22] Systematic radiation dose optimization of abdominal dual-energy CT on a second-generation dual-source CT scanner: assessment of the accuracy of iodine uptake measurement and image quality in an in vitro and in vivo investigations
    Schindera, Sebastian T.
    Zaehringer, Caroline
    D'Errico, Luigia
    Schwartz, Fides
    Kekelidze, Maka
    Szucs-Farkas, Zsolt
    Benz, Matthias R.
    ABDOMINAL RADIOLOGY, 2017, 42 (10) : 2562 - 2570
  • [23] Dose Reduction in Abdominal Computed Tomography Intraindividual Comparison of Image Quality of Full-Dose Standard and Half-Dose Iterative Reconstructions With Dual-Source Computed Tomography
    May, Matthias S.
    Wuest, Wolfgang
    Brand, Michael
    Stahl, Christian
    Allmendinger, Thomas
    Schmidt, Bernhard
    Uder, Michael
    Lell, Michael M.
    INVESTIGATIVE RADIOLOGY, 2011, 46 (07) : 465 - 470
  • [24] The ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography
    Ying Liu
    Jian Xu
    Jian Li
    Jing Ren
    Hongtao Liu
    Junqing Xu
    Mengqi Wei
    Yuewen Hao
    Minwen Zheng
    Journal of Cardiothoracic Surgery, 8
  • [25] Ultra-low-dose chest CT in adult patients with cystic fibrosis using a third-generation dual-source CT scanner
    Tagliati, Corrado
    Lanza, Cecilia
    Pieroni, Giovanni
    Amici, Lucia
    Carotti, Marina
    Giuseppetti, Gian Marco
    Giovagnoni, Andrea
    RADIOLOGIA MEDICA, 2021, 126 (04): : 544 - 552
  • [26] Dual-source CT coronary angiography: effectiveness of radiation dose reduction with lower tube voltage
    Sabarudin, Akmal
    Yusof, Ahmad Khairuddin Md
    Tay, May Fang
    Ng, Kwan-Hoong
    Sun, Zhonghua
    RADIATION PROTECTION DOSIMETRY, 2013, 153 (04) : 441 - 447
  • [27] Prospective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose
    Zhuang, Y.
    Huang, W.
    Shi, Y.
    Bo, G.
    Lu, D.
    Zhang, J.
    Kong, D.
    Shit, Y.
    Wang, B.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (02): : 225 - 233
  • [28] Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction
    Rompel, Oliver
    Gloeckler, Martin
    Janka, Rolf
    Dittrich, Sven
    Cesnjevar, Robert
    Lell, Michael M.
    Uder, Michael
    Hammon, Matthias
    PEDIATRIC RADIOLOGY, 2016, 46 (04) : 462 - 472
  • [29] Effect of automated tube voltage selection, integrated circuit detector and advanced iterative reconstruction on radiation dose and image quality of 3rd generation dual-source aortic CT angiography: An intra-individual comparison
    Mangold, Stefanie
    De Cecco, Carlo N.
    Wichmann, Julian L.
    Canstein, Christian
    Varga-Szemes, Akos
    Caruso, Damiano
    Fuller, Stephen R.
    Bamberg, Fabian
    Nikolaou, Konstantin
    Schoepf, U. Joseph
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (05) : 972 - 978
  • [30] Third-generation dual-source 70-kVp chest CT angiography with advanced iterative reconstruction in young children: image quality and radiation dose reduction
    Oliver Rompel
    Martin Glöckler
    Rolf Janka
    Sven Dittrich
    Robert Cesnjevar
    Michael M. Lell
    Michael Uder
    Matthias Hammon
    Pediatric Radiology, 2016, 46 : 462 - 472