Choice of Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Impacts Hemodynamics Differently According to Aortic Annular Size

被引:35
作者
Rogers, Toby [1 ,2 ]
Steinvil, Arie [1 ]
Gai, Jiaxiang [1 ]
Torguson, Rebecca [1 ]
Koifman, Edward [1 ]
Kiramijyan, Sarkis [1 ]
Negi, Smita [1 ]
Lee, Sang Yeub [1 ]
Okubagzi, Petros [1 ]
Satler, Lowell F. [1 ]
Ben-Dor, Itsik [1 ]
Pichard, Augusto D. [1 ]
Waksman, Ron [1 ]
机构
[1] MedStar Washington Hosp Ctr, Sect Intervent Cardiol, Washington, DC 20010 USA
[2] NHLBI, Cardiovasc & Pulm Branch, Div Intramural Res, NIH, Bldg 10, Bethesda, MD 20892 USA
关键词
PARTNER TRIAL; IN-VITRO; REPLACEMENT; OUTCOMES; IMPLANTATION; PERFORMANCE; STENOSIS;
D O I
10.1016/j.amjcard.2016.11.044
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We sought to determine whether balloon-expandable valve (BEV) and self-expanding valve (SEV) affect valve hemodynamics differently according to native aortic annulus size. Transcatheter aortic valve replacement can achieve superior prosthetic valve hemodynamics compared with surgical aortic valve replacement, particularly in patients with small aortic annulus. One hundred ninety-three consecutive transcatheter aortic valve replacement patients were grouped into tertiles defined by computed tomography derived aortic annulus systolic perimeter. The predischarge echocardiogram was analyzed for prosthetic valve hemodynamics. Tertile perimeter cutoffs were 73 and 80 mm. STS score decreased as annulus size increased (7.8% vs 7.6% vs 6.0%, p <= 0.05 for small, medium, and large annulus, respectively). In patients with small aortic annulus, SEV was associated with significantly higher dimensionless index (0.64 vs 0.53, p = 0.02) and lower peak velocity (1.8 vs 2.4 m/sec, p <0.001) and a trend toward lower mean gradient (7.5 vs 10.0 mm Hg, p = 0.07) compared with BEV. These differences were attenuated and absent in patients with medium and large annulus, respectively. Few patients had moderate/severe paravalvular leak, with no association with valve type or annulus size. There was no difference in mortality between tertiles or valve type at 30 days or 1 year. There was no association between aortic annulus perimeter and 1-year mortality by univariate analysis (hazard ratio 1.00, 95% CI 0.95 to 1.05, p = 0.86) or multivariate analysis (hazard ratio 1.02, 95% CI 0.95 to 1.09, p = 0.60). In conclusion, SEV hemodynamics was superior to BEV in patients with small aortic annulus. This difference was diminished in patients with larger aortic annulus. This study highlights the importance of valve selection in patients with small aortic annulus. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:900 / 904
页数:5
相关论文
共 11 条
  • [1] Comparison of Balloon-Expandable vs Self-expandable Valves in Patients Undergoing Transcatheter Aortic Valve Replacement The CHOICE Randomized Clinical Trial
    Abdel-Wahab, Mohamed
    Mehilli, Julinda
    Frerker, Christian
    Neumann, Franz-Josef
    Kurz, Thomas
    Toelg, Ralph
    Zachow, Dirk
    Guerra, Elena
    Massberg, Steffen
    Schaefer, Ulrich
    El-Mawardy, Mohamed
    Richardt, Gert
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 311 (15): : 1503 - 1514
  • [2] [Anonymous], 2015, J Biomech, DOI DOI 10.1016/J.JBIOMECH.2015.08.012
  • [3] Valve-in-Valve Implantation Using a Novel Supravalvular Transcatheter Aortic Valve: Proof of Concept
    Azadani, Ali N.
    Jaussaud, Nicolas
    Matthews, Peter B.
    Ge, Liang
    Guy, T. Sloane
    Chuter, Timothy A. M.
    Tseng, Elaine E.
    [J]. ANNALS OF THORACIC SURGERY, 2009, 88 (06) : 1864 - 1870
  • [4] Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis
    Clavel, Marie-Annick
    Webb, John G.
    Pibarot, Philippe
    Altwegg, Lukas
    Dumont, Eric
    Thompson, Chris
    De Larochelliere, Robert
    Doyle, Daniel
    Masson, Jean-Bernard
    Bergeron, Sebastien
    Bertrand, Olivier F.
    Rodes-Cabau, Josep
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (20) : 1883 - 1891
  • [5] Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves
    Dvir, Danny
    Webb, John G.
    Bleiziffer, Sabine
    Pasic, Miralem
    Waksman, Ron
    Kodali, Susheel
    Barbanti, Marco
    Latib, Azeem
    Schaefer, Ulrich
    Rodes-Cabau, Josep
    Treede, Hendrik
    Piazza, Nicolo
    Hildick-Smith, David
    Himbert, Dominique
    Walther, Thomas
    Hengstenberg, Christian
    Nissen, Henrik
    Bekeredjian, Raffi
    Presbitero, Patrizia
    Ferrari, Enrico
    Segev, Amit
    de Weger, Arend
    Windecker, Stephan
    Moat, Neil E.
    Napodano, Massimo
    Wilbring, Manuel
    Cerillo, Alfredo G.
    Brecker, Stephen
    Tchetche, Didier
    Lefevre, Thierry
    De Marco, Federico
    Fiorina, Claudia
    Petronio, Anna Sonia
    Teles, Rui C.
    Testa, Luca
    Laborde, Jean-Claude
    Leon, Martin B.
    Kornowski, Ran
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 312 (02): : 162 - 170
  • [6] Comparison of Transcatheter and Surgical Aortic Valve Replacement in Severe Aortic Stenosis
    Hahn, Rebecca T.
    Pibarot, Philippe
    Stewart, William J.
    Weissman, Neil J.
    Gopalakrishnan, Deepika
    Keane, Martin G.
    Anwaruddin, Saif
    Wang, Zuyue
    Bilsker, Martin
    Lindman, Brian R.
    Herrmann, Howard C.
    Kodali, Susheel K.
    Makkar, Raj
    Thourani, Vinod H.
    Svensson, Lars G.
    Akin, Jodi J.
    Anderson, William N.
    Leon, Martin B.
    Douglas, Pamela S.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (25) : 2514 - 2521
  • [7] Paravalvular regurgitation after transcatheter aortic valve replacement with the Edwards sapien valve in the PARTNER trial: characterizing patients and impact on outcomes
    Kodali, Susheel
    Pibarot, Philippe
    Douglas, Pamela S.
    Williams, Mathew
    Xu, Ke
    Thourani, Vinod
    Rihal, Charanjit S.
    Zajarias, Alan
    Doshi, Darshan
    Davidson, Michael
    Tuzcu, E. Murat
    Stewart, William
    Weissman, Neil J.
    Svensson, Lars
    Greason, Kevin
    Maniar, Hersh
    Mack, Michael
    Anwaruddin, Saif
    Leon, Martin B.
    Hahn, Rebecca T.
    [J]. EUROPEAN HEART JOURNAL, 2015, 36 (07) : 449 - +
  • [8] Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
    Kodali, Susheel K.
    Williams, Mathew R.
    Smith, Craig R.
    Svensson, Lars G.
    Webb, John G.
    Makkar, Raj R.
    Fontana, Gregory P.
    Dewey, Todd M.
    Thourani, Vinod H.
    Pichard, Augusto D.
    Fischbein, Michael
    Szeto, Wilson Y.
    Lim, Scott
    Greason, Kevin L.
    Teirstein, Paul S.
    Malaisrie, S. Chris
    Douglas, Pamela S.
    Hahn, Rebecca T.
    Whisenant, Brian
    Zajarias, Alan
    Wang, Duolao
    Akin, Jodi J.
    Anderson, William N.
    Leon, Martin B.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2012, 366 (18) : 1686 - 1695
  • [9] How Can We Help a Patient With a Small Failing Bioprosthesis? An In Vitro Case Study
    Midha, Prem A.
    Raghav, Vrishank
    Condado, Jose F.
    Arjunon, Sivakkumar
    Uceda, Domingo E.
    Lerakis, Stamatios
    Thourani, Vinod H.
    Babaliaros, Vasilis
    Yoganathan, Ajit P.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (15) : 2026 - 2033
  • [10] Impact of Aortic Annulus Size on Valve Hemodynamics and Clinical Outcomes After Transcatheter and Surgical Aortic Valve Replacement Insights From the PARTNER Trial
    Rodes-Cabau, Josep
    Pibarot, Philippe
    Suri, Rakesh M.
    Kodali, Susheel
    Thourani, Vinod H.
    Szeto, Wilson Y.
    Svensson, Lars G.
    Dumont, Eric
    Xu, Ke
    Hahn, Rebecca T.
    Leon, Martin B.
    [J]. CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (05) : 701 - +