In Vitro Testing of Femoral Impaction Grafting With Porous Titanium Particles: A Pilot Study

被引:7
作者
Aquarius, Rene [1 ]
Walschot, Luc [1 ]
Buma, Pieter [1 ]
Schreurs, Berend Willem [2 ]
Verdonschot, Nico [1 ,3 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Orthopaed Res Lab, NL-6500 HB Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Med Ctr, Dept Orthopaed, NL-6500 HB Nijmegen, Netherlands
[3] Univ Twente, Dept Biomech Engn, NL-7500 AE Enschede, Netherlands
关键词
REVISION TOTAL HIP; MORSELLIZED BONE-GRAFTS; KNEE ARTHROPLASTY; ALLOGRAFT BONE; 3RD-BODY WEAR; CEMENT MANTLE; POLYETHYLENE; REPLACEMENT; RECONSTRUCTION; OSTEOLYSIS;
D O I
10.1007/s11999-008-0688-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The disadvantages of allografts to restore femoral bone defects during revision hip surgery have led to the search for alternative materials. We investigated the feasibility of using porous titanium particles and posed the following questions: (1) Is it possible to create a high-quality femoral graft of porous titanium particles in terms of graft thickness, cement thickness, and cement penetration? (2) Does this titanium particle graft layer provide initial stability when a femoral cemented stem is implanted in it? (3) What sizes of particles are released from the porous titanium particles during impaction and subsequent cyclic loading of the reconstruction? We simulated cemented revision reconstructions with titanium particles in seven composite femurs loaded for 300,000 cycles and measured stem subsidence. Particle release from the titanium particle grafts was analyzed during impaction and loading. Impacted titanium particles formed a highly interlocked graft layer. We observed limited cement penetration into the titanium particle graft. A total mean subsidence of 1.04 mm was observed after 300,000 cycles. Most particles released during impaction were in the phagocytable range (< 10 mu m). There was no detectable particle release during loading. Based on the data, we believe titanium particles are a promising alternative for allografts. However, animal testing is warranted to investigate the biologic effect of small-particle release.
引用
收藏
页码:1538 / 1545
页数:8
相关论文
共 49 条
  • [1] [Anonymous], 2003, MMWR. Morbidity and mortality weekly report, V52, P276
  • [2] Arthrodesis of the knee with a modular titanium intramedullary nail
    Arroyo, JS
    Garvin, KL
    Neff, JR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (01) : 26 - 35
  • [3] No negative effects of bone impaction grafting with bone and ceramic mixtures
    Arts, JJC
    Gardeniers, JWM
    Welten, MLM
    Verdonschot, N
    Schreurs, BW
    Buma, P
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (438) : 239 - 247
  • [4] Barker R, 2006, J BONE JOINT SURG BR, V88B, P832, DOI 10.1302/0301/620X.88B6
  • [5] Acetabular defect reconstruction with impacted morsellized bone grafts or TCP/HA particles. A study on the mechanical stability of cemented cups in an artificial acetabulum model
    Bolder, SBT
    Verdonschot, N
    Schreurs, BW
    Buma, P
    [J]. BIOMATERIALS, 2002, 23 (03) : 659 - 666
  • [6] The initial stability of cemented acetabular cups can be augmented by mixing morsellized bone grafts with tricalciumphosphate/hydroxyapatite particles in bone impaction grafting
    Bolder, SBT
    Verdonschot, N
    Schreurs, BW
    Buma, P
    [J]. JOURNAL OF ARTHROPLASTY, 2003, 18 (08) : 1056 - 1063
  • [7] Third-body wear testing of a highly cross-linked acetabular liner - The effect of large femoral head size in the presence of particulate poly (methyl-methacrylate) debris
    Bragdon, CR
    Jasty, M
    Muratoglu, OK
    Harris, WH
    [J]. JOURNAL OF ARTHROPLASTY, 2005, 20 (03) : 379 - 385
  • [8] Third-body wear of highly cross-linked polyethylene in a hip simulator
    Bragdon, CR
    Jasty, M
    Muratoglu, OK
    O'Connor, DO
    Harris, WH
    [J]. JOURNAL OF ARTHROPLASTY, 2003, 18 (05) : 553 - 561
  • [9] Centers for Disease Control and Prevention (CDC), 2003, MMWR Morb Mortal Wkly Rep, V52, P273
  • [10] TRANSMISSION OF THE HEPATITIS-C VIRUS BY TISSUE-TRANSPLANTATION
    CONRAD, EU
    GRETCH, DR
    OBERMEYER, KR
    MOOGK, MS
    SAYERS, M
    WILSON, JJ
    STRONG, M
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (02) : 214 - 224