摘要
The purpose of this study was to compare the anatomical fit of different, precontoured palmar distal radius plates. The anatomical fit of seven different types of palmar distal radius plates [Konigsee variable fixed-angle radius plate 7/3-hole, Konigsee variable fixed-angle radius plate 5/3-hole (Allendorf, Germany), Medartis 2.5 Adaptive TriLock, Medartis 2.5 TriLock, Medartis 2.5 TriLock extraarticular, (Basel, Switzerland), Synthes VA-LCP distal two-column-radius, Synthes LCP extraarticular (Bettlach, Switzerland)] were investigated in 25 embalmed human cadaveric radii. An imprint of the space between the well-positioned plate and the distal radius was attained using a silicone mass and the maximum height of the silicone imprint was digitally measured. The mean maximum imprint height was compared between the seven plates using an analysis of variance with repeated measures and Bonferroni correction for multiple comparisons. The mean maximum distance between the plates and the radial cortex was < 2 mm for all plates. The greatest difference was found with the Medartis Adaptive (1.99 +/- A 0.45 mm) and the least difference with the Synthes two-column (1.56 +/- A 0.76 mm), this difference being statistically significant (p = 0.005). Although there was no complete congruency between the plates and the radial cortex, all distal palmar radius plates investigated in this study presented a reasonable anatomical shape. The Synthes VA-LCP distal two-column-radius plate palmar showed the best anatomical fit. A low profile and optimized anatomical precontouring minimizes irritation of the surrounding soft tissues and should be considered with plate design and implant choice.
引用
收藏
页码:1483 / 1489
页数:7
相关论文
共 40 条
  • [1] Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate
    Arora, Rohit
    Lutz, Martin
    Hennerbichler, Alfred
    Krappinger, Dietinar
    Espen, David
    Gabl, Markus
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) : 316 - 322
  • [2] Palmar cortical angle of the distal radius: A radiological study
    Bassi, RS
    Krishnan, KM
    Dhillon, SS
    Deshmukh, SC
    [J]. JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2003, 28B (02) : 163 - 164
  • [3] Volar Plate Fixation Failure for Volar Shearing Distal Radius Fractures With Small Lunate Facet Fragments
    Beck, John D.
    Harness, Neil G.
    Spencer, Hillard T.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (04): : 670 - 678
  • [4] Brown E N., 2011, Eplasty, V11, P461
  • [5] Precontoured fixed-angle volar distal radius plates: A comparison of anatomic fit
    Buzzell, Jonathan E.
    Weikert, Douglas R.
    Watson, Jeffry T.
    Lee, Donald H.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (07): : 1144 - 1152
  • [6] Epidemiology of adult fractures: A review
    Court-Brown, Charles M.
    Caesar, Ben
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (08): : 691 - 697
  • [7] Flexor tendon injuries following locked volar plating of distal radius fractures
    Cross, Andrew W.
    Schmidt, Christopher C.
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (02): : 164 - 167
  • [8] More is not necessarily better. A biomechanical study on distal screw numbers in volar locking distal radius plates
    Drobetz, Herwig
    Weninger, Patrick
    Grant, Caroline
    Heal, Clare
    Muller, Reinhold
    Schuetz, Michael
    Pham, Minh
    Steck, Roland
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2013, 44 (04): : 535 - 539
  • [9] Complications following palmar plate fixation of distal radius fractures: a review of 665 cases
    Esenwein, P.
    Sonderegger, J.
    Gruenert, J.
    Ellenrieder, B.
    Tawfik, J.
    Jakubietz, M.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2013, 133 (08) : 1155 - 1162
  • [10] Distal volar radial plates: How anatomical are they?
    Evans, S.
    Ramasamy, A.
    Deshmukh, S. C.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2014, 100 (03) : 293 - 295