Quantitative performance of liquid chromatography coupled to Q-Exactive high resolution mass spectrometry (HRMS) for the analysis of tetracyclines in a complex matrix

被引:67
作者
Solliec, Morgan [1 ]
Roy-Lachapelle, Audrey [1 ]
Sauve, Sebastien [1 ]
机构
[1] Univ Montreal, Dept Chem, Montreal, PQ H3C 3J7, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Exact mass; High resolution mass spectrometry; Orbitrap; Tetracyclines; Liquid chromatography; SOLID-PHASE EXTRACTION; SULFONAMIDE ANTIBIOTICS; VETERINARY ANTIBIOTICS; ANALYTICAL METHODOLOGY; ORBITRAP; WATER; OXYTETRACYCLINE; UV; ANTIMICROBIALS; GROUNDWATER;
D O I
10.1016/j.aca.2014.10.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The presence of antibiotics in the environment is of increased interest and, as modern mass spectrometers become more efficient, we are increasingly aware of traces of pharmaceuticals appearing in a wide range of environmental and biological matrices. The Q-Exactive mass spectrometer is part of these innovative hybrid high-resolution mass spectrometers (HRMS) which is often associated with peptide sequencing or metabolomics but with a limited number of studies focusing on its application to the quantification of small molecules in environmental and biological matrices. It combines the high resolving power (RP) performance of the Orbitrap with the high performance selectivity of the quadrupole. Tetracyclines (TCs) are a family comprising some of the most widely used antibiotics in veterinary medicine. This study presents the quantitative performances of the Q-Exactive by illustrating a new approach to quantify TCs using liquid chromatography coupled to a HRMS in a complex matrix, i.e., swine manure. The Q-Exactive was used at high-resolution in both full scan (FS) and targeted ion fragmentation (tMS(2)) modes. These two modes were optimized and compared to determine the most reliable and efficient approach to quantify TCs with good accuracy. The proposed method was optimized to obtain the best selectivity and sensitivity, thus eliminating false positive and allowing the detection of trace levels of analyte. The TCs were extracted from the matrix by sonication using McIlvaine buffer followed by an off-line solid phase extraction method to concentrate and clean the extracts. Both FS and tMS(2) modes presented good linearity (R-2 > 0.991) and repeatability (RSD < 15%). Mass accuracy was acceptable with values below 2 ppm. The method detection limits (MLD) calculated from the calibration curves ranged from 2.0 to 12 ng g(-1) for FS mode and from 1.5 to 3.6 ng g(-1) for tMS(2) mode. Accuracy and interday/intraday relative standard deviations were below 21% for both modes studied. TCs were quantified in real samples of swine manure with concentrations ranging from 29 to 75 ng g(-1). This study showed the possibility of using hybrid HRMS for trace detection and quantification of TCs in a complex matrix, thus avoiding false positive while achieving good selectivity and sensitivity. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:415 / 424
页数:10
相关论文
共 37 条
[1]   Determination of the persistence of tetracycline antibiotics and their degradates in manure-amended soil using enzyme-linked immunosorbent assay and liquid chromatography-mass spectrometry [J].
Aga, DS ;
O'Connor, S ;
Ensley, S ;
Payero, JO ;
Snow, D ;
Tarkalson, D .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2005, 53 (18) :7165-7171
[2]   The ion suppression phenomenon in liquid chromatography-mass spectrometry and its consequences in the field of residue [J].
Antignac, JP ;
de Wasch, K ;
Monteau, F ;
De Brabander, H ;
Andre, F ;
Le Bizec, B .
ANALYTICA CHIMICA ACTA, 2005, 529 (1-2) :129-136
[3]  
Bakhtiarian A, 2009, ANN NUTR METAB, V55, P162
[4]   Quantitative-Qualitative Data Acquisition Using a Benchtop Orbitrap Mass Spectrometer [J].
Bateman, Kevin P. ;
Kellmann, Markus ;
Muenster, Helmut ;
Papp, Robert ;
Taylor, Lester .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2009, 20 (08) :1441-1450
[5]   Ultrasonic extraction of veterinary antibiotics from soils and pig slurry with SPE clean-up and LC-UV and fluorescence detection [J].
Blackwell, PA ;
Lützhoft, HCH ;
Ma, HP ;
Halling-Sorensen, B ;
Boxall, ABA ;
Kay, P .
TALANTA, 2004, 64 (04) :1058-1064
[6]   Fast and robust simultaneous determination of three veterinary antibiotics in groundwater and surface water using a tandem solid-phase extraction with high-performance liquid chromatography-UV detection [J].
Blackwell, PA ;
Lützhoft, HCH ;
Ma, HP ;
Halling-Sorensen, B ;
Boxall, ABA ;
Kay, P .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1045 (1-2) :111-117
[7]   Accurate Mass Measurement: Terminology and Treatment of Data [J].
Brenton, A. Gareth ;
Godfrey, A. Ruth .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2010, 21 (11) :1821-1835
[8]   Matrix effects and recovery calculations in analyses of pharmaceuticals based on the determination of β-blockers and β-agonists in environmental samples [J].
Caban, Magda ;
Migowska, Natalia ;
Stepnowski, Piotr ;
Kwiatkowski, Marek ;
Kumirska, Jolanta .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1258 :117-127
[9]   Comparison of the quantitative performance of a Q-Exactive high-resolution mass spectrometer with that of a triple quadrupole tandem mass spectrometer for the analysis of illicit drugs in wastewater [J].
Fedorova, Ganna ;
Randak, Tomas ;
Lindberg, Richard H. ;
Grabic, Roman .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (15) :1751-1762
[10]   Determination of persistent tetracycline residues in soil fertilized with liquid manure by high-performance liquid chromatography with electrospray ionization tandem mass spectrometry [J].
Hamscher, G ;
Sczesny, S ;
Höper, H ;
Nau, H .
ANALYTICAL CHEMISTRY, 2002, 74 (07) :1509-1518