Pentacam Scheimpflug Tomography Findings in Chinese Patients With Different Corneal Diameters

被引:9
作者
Ding, Lan [1 ]
Wang, Jifang [1 ]
Niu, Lingling [1 ]
Shi, Wanru [1 ]
Qian, Yishan [1 ]
机构
[1] Fudan Univ, Eye & ENT Hosp, Dept Ophthalmol, NHC Key Lab Myopia, Shanghai, Peoples R China
关键词
OCULAR RESPONSE ANALYZER; FORME-FRUSTE KERATOCONUS; PARAMETERS; EYES; ELEVATION; ECTASIA;
D O I
10.3928/1081597X-20200730-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the Pentacam (Ocutus Optikgerate) Scheimpflug tomography findings in Chinese patients with different corneal diameters. METHODS: This prospective cross-sectional study included candidates for correction of myopia with normal tomography (ABCD keratoconus grading system, stage 0). The participants were grouped according to their horizontal corneal diameters. Pentacam ectasia detection indices were compared between different corneal diameter-based groups. RESULTS: A total of 643 eyes were included (corneal. diameter <= 11 mm, n = 206; 11 to 12 mm, n = 219; >= 12 mm, n = 218). The corneal powers and the thinnest pachymetry were negatively correlated with corneal diameter (linear regression analysis, P < .001). However, the corneal astigmatism was positively correlated with corneal diameter (R-2 = 0.03, P < .001). Both the front (FE) and back (BE) elevations were negatively correlated with corneal diameter (FE: R-2 = 0.027, P < .001; BE: R-2 = 0.274, P < .001). The three pachymetric progression indices (PPI) (minimum, maximum, and average) were negatively correlated with corneal diameter (PPImin: R-2 = 0.164, P < .001; PPImax: R-2 =0.06, P < .001; PPlavg: R-2 = 0.158, P < .001). The maximum Ambrosio's relational thickness (ARTmax) also was positively correlated with corneal diameter (R-2 = 0.031, P < .001). Five normalized indices were negatively correlated with corneal diameter (deviation of normality of the front elevation [Df]: R-2 = 0.122, P < .001; deviation of normality of the back elevation [Db]: R-2 = 0.47, P < .001; deviation of normality of pachymetric progression [Dp]: R-2 = 0.159, P < .001; deviation of normality of relational thickness [Da]: R-2 = .031, P < .001; Belin/Ambrosio Enhanced Ectasia display: R-2 = 0.32, P < .0011 and Dt was positively correlated with corneal diameter (R-2 = 0.015, P = .002). Additionally, it was noted that corneal diameter had the greatest influence on Db, Belin/Ambrosio Enhanced Ectasia display (BAD-D), and BE. CONCLUSIONS: Corneal diameter has an influence on the BAD parameters, especially Db, BAD-D, and BE, and therefore should be incorporated as an additional variable in BAD analysis. The analytical dimensions should be individualized for eyes with individual corneal diameter.
引用
收藏
页码:688 / +
页数:11
相关论文
共 30 条
  • [1] Normative Pentacam anterior and posterior corneal elevation measurements: effects of age, sex, axial length and white-to-white
    Almorin-Fernandez-Vigo, Ignacio
    Sanchez-Guillen, Ines
    Fernandez-Vigo, Jose I.
    Macarro-Merino, Ana
    Kudsieh, Bachar
    Fernandez-Vigo, Cristina
    Fernandez-Vigo, Jose A.
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2019, 39 (09) : 1955 - 1963
  • [2] Astigmatism analysis by the Alpins method
    Alpins, N
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (01) : 31 - 49
  • [3] Novel Pachymetric Parameters Based on Corneal Tomography for Diagnosing Keratoconus
    Ambrosio, Renato, Jr.
    Caiado, Ana Laura C.
    Guerra, Frederico P.
    Louzada, Ricardo
    Roy, Abhijit Sinha
    Luz, Allan
    Dupps, William J.
    Belin, Michael W.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (10) : 753 - 758
  • [4] Comparison of Chinese and North American Tomographic Parameters and the Implications for Refractive Surgery Screening
    Boyd, Brennan M.
    Bai, Ji
    Borgstrom, Mark
    Belin, Michael W.
    [J]. ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2020, 9 (02): : 117 - 125
  • [5] Orbscan computerized topography: Attributes, applications, and limitations
    Cairns, G
    McGhee, CNJ
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) : 205 - 220
  • [6] Analysis of cases and accuracy of 3 risk scoring systems in predicting ectasia after laser in situ keratomileusis
    Chan, Cordelia
    Saad, Alain
    Randleman, J. Bradley
    Harissi-Dagher, Mona
    Chua, Daniel
    Qazi, Mujtaba
    Saragoussi, Jean-Jacques
    Shetty, Rohit
    Ancel, Jean-Marc
    Ang, Robert
    Reinstein, Dan Z.
    Gatinel, Damien
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (08) : 979 - 992
  • [7] Validation of an Objective Scoring System for Forme Fruste Keratoconus Detection and Post-LASIK Ectasia Risk Assessment in Asian Eyes
    Chan, Cordelia
    Ang, Marcus
    Saad, Alain
    Chua, Daniel
    Mejia, Margarita
    Lim, Li
    Gatinel, Damien
    [J]. CORNEA, 2015, 34 (09) : 996 - 1004
  • [8] Comparison of corneal dynamic parameters and tomographic measurements using Scheimpflug imaging in keratoconus
    Chan, Tommy C. Y.
    Wang, Yu Meng
    Yu, Marco
    Jhanji, Vishal
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2018, 102 (01) : 42 - 47
  • [9] EDMUND C, 1988, ACTA OPHTHALMOL, V66, P376
  • [10] International values of corneal elevation in normal subjects by rotating Scheimpflug camera
    Feng, Matthew T.
    Belin, Michael W.
    Ambrosio, Renato, Jr.
    Grewal, Satinder P. S.
    Yan, Wang
    Shaheen, Mohamed Shafik
    Jordon, Charlotte A.
    McGhee, Charles
    Maeda, Naoyuki
    Neuhann, Tobias H.
    Dick, H. Burkhard
    Steinmueller, Andreas
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (10) : 1817 - 1821