Polyvinyl alcohol-Fricke hydrogel and cryogel:: two new gel dosimetry systems with low Fe3+ diffusion

被引:104
作者
Chu, KC
Jordan, KJ
Battista, JJ
Van Dyk, J
Rutt, BK
机构
[1] London Reg Canc Ctr, London, ON N6A 4L6, Canada
[2] John P Robarts Res Inst, London, ON N6A 5K8, Canada
[3] Univ Western Ontario, London, ON, Canada
关键词
D O I
10.1088/0031-9155/45/4/311
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Two new Fricke dosimeter gel systems with low diffusion rates have been developed fro 3D radiation dosimetry purposes. Both systems consist of a solution of 20% (by weight) polyvinyl alcohol (PVA) in a 50 mM H2SO4 solution with 0.4 mM ferrous ammonium sulphate and xylenol orange (FX). The difference in the two gels is the way that the gelation process was initiated: either by bringing the temperature to (a) +5 degrees C or (b) -20 degrees C before returning them to room temperature. These gels are termed 'hydrogel' and 'cryogel', respectively. The hydrogel is optically transparent, and can be used with either optical or MRI detection methods for dosimetric imaging. The cryogel is rubbery in texture but opaque, so its internal Fe3+ concentration can only be measured wit MRI. The hydrogel's optical attenuation coefficient is linear (r(2) = 0.99) with dose from 0 to 20 Gy with a sensitivity of 0.106 cm(-1) Gy(-1) (at 543 nm). In terms of MR relaxation rate, the dose response for both the hydrogel and cryogel was linear (r(2) = 0.99) with a sensitivity of 0.020 s(-1) Gy(-1) (at 1.5 T). The Fe3+ diffusion coefficient (at 20 degrees C) was measured to be 0.14 mm(2) h(-1), which is significantly lower than similar preparations reported fro porcine gelatin or agarose. The PVA-FX gel can be stored fro long periods of time before exposure to radiation since the auto- oxidation rate was 10 times less than that of gelatin-Fricke recipes. The new gels developed in this work are a significant improvement on previous Fricke gel systems.
引用
收藏
页码:955 / 969
页数:15
相关论文
共 56 条
  • [1] IMAGING OF RADIATION-DOSE BY VISIBLE COLOR DEVELOPMENT IN FERROUS-AGAROSE-XYLENOL ORANGE GELS
    APPLEBY, A
    LEGHROUZ, A
    [J]. MEDICAL PHYSICS, 1991, 18 (02) : 309 - 312
  • [2] APPLEBY A, 1988, RADIAT PHYS CHEM, V32, P241
  • [3] APPLEBY A, 1999, P 1 C DOSGEL 99 INT, P9
  • [4] Multiple-site fast exchange model for spin-lattice relaxation in the Fricke-gelatin dosimeter
    Audet, C
    Schreiner, LJ
    [J]. MEDICAL PHYSICS, 1997, 24 (02) : 201 - 209
  • [5] Back S A J, 1999, 1 C DOSGEL 99 INT WO, P47
  • [6] DIFFUSION IN FE(II/III) RADIATION-DOSIMETRY GELS MEASURED BY MAGNETIC-RESONANCE-IMAGING
    BALCOM, BJ
    LEES, TJ
    SHARP, AR
    KULKARNI, NS
    WAGNER, GS
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (10) : 1665 - 1676
  • [7] Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry
    Baldock, C
    Burford, RP
    Billingham, N
    Wagner, GS
    Patval, S
    Badawi, RD
    Keevil, SF
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (03) : 695 - 702
  • [8] Measurement of dynamic wedge angles and beam profiles by means of MRI ferrous sulphate gel dosimetry
    Bengtsson, M
    Furre, T
    Rodal, J
    Skretting, A
    Olsen, DR
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (02) : 269 - 277
  • [9] RADIATION EFFECTS ON AQUEOUS SOLUTIONS OF POLYVINYL ALCOHOL
    BERKOWITCH, J
    CHARLESBY, A
    [J]. JOURNAL OF POLYMER SCIENCE, 1957, 25 (111): : 490 - 492
  • [10] RADIATION CROSSLINKING OF NYLON 66 AND POLY (VINYL ALCOHOL)
    BERNSTEIN, BS
    ODIAN, G
    ORBAN, G
    TIRELLI, S
    [J]. JOURNAL OF POLYMER SCIENCE PART A-GENERAL PAPERS, 1965, 3 (10PA): : 3405 - +