Preparation of morin modified nanometer SiO2 as a sorbent for solid-phase extraction of trace heavy metals from biological and natural water samples

被引:19
作者
Zou, Xiaojun [1 ,3 ]
Cui, Yuemei [2 ]
Zhu, Xiangbing [1 ]
Hu, Zheng [1 ]
Chang, Xijun [1 ]
机构
[1] Lanzhou Univ, Dept Chem, Lanzhou 730000, Peoples R China
[2] Jining Bur Qual & Tech Supervis, Jining 272000, Peoples R China
[3] Shandong Lukang Pharmaceut Co Ltd, Jining 272100, Peoples R China
关键词
Nanometer SiO2; Morin; Heavy metal ions; Solid-phase extraction (SPE); ICP-AES; ATOMIC-ABSORPTION-SPECTROMETRY; MODIFIED SILICA-GEL; ONLINE PRECONCENTRATION; EMISSION-SPECTROMETRY; ICP-AES; COLUMN; IONS; SEPARATION; SURFACE; PYROCATECHOL;
D O I
10.1007/s10971-009-1901-x
中图分类号
TQ174 [陶瓷工业]; TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Morin was successful as a chemical modifier to improve the reactivity of the nanometer SiO2 surface in terms of selective binding and extraction of heavy metal ions. This new functionalized nanometer SiO2 (nanometer SiO2-morin) was used as an effective sorbent for the solid-phase extraction (SPE) of Cd(II), Cu(II), Ni(II), Pb(II), Zn(II) in solutions prior to its determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions for effective adsorption of trace levels of metal ions were optimized with respect to different experimental parameters using static and dynamic procedures in detail. The pH 4.0 was chosen as the optimum pH value for the separation of metal ions on the newly sorbent. Complete elution of the adsorbed metal ions from the nanometer SiO2-morin was carried out using 2.0 mL of 0.5 mol L-1 of HCl. Common coexisting ions did not interfere with the separation and determination at pH 4.0. The maximum static adsorption capacity of the sorbent at optimum conditions was found to be 22.36, 36.8, 40.37, 33.21 and 25.99 mg metal/g SiO2-morin for Cd(II), Cu(II), Ni(II), Pb(II) and Zn(II), respectively. The time for 95% sorption for Cu(II) and Ni(II) and 70% sorption for Cd(II), Pb(II) and Zn(II) was less than 2 min. The relative standard deviation (RSD) of the method under optimum conditions was lower than 5.0% (n = 11). The procedure was validated by analyzing the certified reference river sediment material (GBW 08301, China), the results obtained were in good agreement with standard values. The nanometer SiO2-morin was successfully employed in the separation and preconcentration of trace Cd(II), Cu(II), Ni(II), Pb(II) and Zn(II) from the biological and natural water samples yielding 75-folds concentration factor.
引用
收藏
页码:35 / 43
页数:9
相关论文
共 36 条
[1]   The retention of metal species by different solid sorbents - Mechanisms for heavy metal speciation by sequential three column uptake [J].
Abollino, O ;
Aceto, M ;
Sarzanini, C ;
Mentasti, E .
ANALYTICA CHIMICA ACTA, 2000, 411 (1-2) :223-237
[2]   Separation and preconcentration in a batch mode of Cd(II), Cr(III, VI), Cu(II), Mn(II, VII) and Pb(II) by solid-phase extraction by using of silica modified with N-propylsalicylaldimine [J].
Abou-El-Sherbini, KS ;
Kenawy, IMM ;
Hamed, MA ;
Issa, RM ;
Elmorsi, R .
TALANTA, 2002, 58 (02) :289-300
[3]  
[Anonymous], PROGR CHEM
[4]   Sorption of arsenic, bismuth, mercury, antimony, selenium and tin on dithiocarbamate loaded polyurethane foam as a preconcentration method for their determination in water samples by simultaneous inductively coupled plasma atomic emission spectrometry and electrothermal atomic absorption spectrometry [J].
Arpadjan, S ;
Vuchkova, L ;
Kostadinova, E .
ANALYST, 1997, 122 (03) :243-246
[5]   SURFACE MODIFICATION OF COLLOIDAL SILICA [J].
BADLEY, RD ;
FORD, WT ;
MCENROE, FJ ;
ASSINK, RA .
LANGMUIR, 1990, 6 (04) :792-801
[6]  
Chiang YM, 1997, J ELECTROCERAM, V1, P205, DOI 10.1023/A:1009958625841
[7]   ICP-AES determination of trace elements after preconcentrated with p-dimethylaminobenzaldehyde-modified nanometer SiO2 from sample solution [J].
Cui, Yuemei ;
Chang, Xijun ;
Zhai, Yiinhui ;
Zhu, Xiangbing ;
Zheng, Hong ;
Lian, Ning .
MICROCHEMICAL JOURNAL, 2006, 83 (01) :35-41
[8]   PREPARATION AND ANALYTICAL PROPERTIES OF A CHELATING RESIN CONTAINING BICINE GROUPS [J].
DEV, K ;
RAO, GN .
TALANTA, 1995, 42 (04) :591-596
[9]   Applying magnesium hydroxide coprecipitation method for trace analysis to dialysis concentrate [J].
Elci, L ;
Saracoglu, S .
TALANTA, 1998, 46 (06) :1305-1310
[10]   FLUORIMETRIC DETERMINATION OF ZIRCONIUM WITH MORIN [J].
GEIGER, RA ;
SANDELL, EB .
ANALYTICA CHIMICA ACTA, 1957, 16 (04) :346-354