Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: state of the art

被引:182
作者
Stradiotti, P. [1 ]
Curti, A. [1 ]
Castellazzi, G. [1 ]
Zerbi, A. [1 ]
机构
[1] IRCCS Ist Ortoped Galeazzi, I-20161 Milan, Italy
关键词
CT; MRI; Artifacts; TOTAL HIP-ARTHROPLASTY; MAGNETIC-RESONANCE; SUSCEPTIBILITY ARTIFACTS; ORTHOPEDIC HARDWARE; IMAGING PARAMETERS; REDUCTION; IMPLANTS; ECHO; SCREWS; OSTEOSYNTHESIS;
D O I
10.1007/s00586-009-0998-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The projectional nature of radiogram limits its amount of information about the instrumented spine. MRI and CT imaging can be more helpful, using cross-sectional view. However, the presence of metal-related artifacts at both conventional CT and MRI imaging can obscure relevant anatomy and disease. We reviewed the literature about overcoming artifacts from metallic orthopaedic implants at high-field strength MRI imaging and multi-detector CT. The evolution of multichannel CT has made available new techniques that can help minimizing the severe beam-hardening artifacts. The presence of artifacts at CT from metal hardware is related to image reconstruction algorithm (filter), tube current (in mA), X-ray kilovolt peak, pitch, hardware composition, geometry (shape), and location. MRI imaging has been used safely in patients with orthopaedic metallic implants because most of these implants do not have ferromagnetic properties and have been fixed into position. However, on MRI imaging metallic implants may produce geometric distortion, the so-called susceptibility artifact. In conclusion, although 140 kV and high milliamperage second exposures are recommended for imaging patients with hardware, caution should always be exercised, particularly in children, young adults, and patients undergoing multiple examinations. MRI artifacts can be minimized by positioning optimally and correctly the examined anatomy part with metallic implants in the magnet and by choosing fast spin-echo sequences, and in some cases also STIR sequences, with an anterior to posterior frequency-encoding direction and the smallest voxel size.
引用
收藏
页码:S102 / S108
页数:7
相关论文
共 34 条
[11]   FAST SPIN-ECHO INVERSION-RECOVERY IMAGING VERSUS FAST T2-WEIGHTED SPIN-ECHO IMAGING IN BONE-MARROW ABNORMALITIES [J].
HILFIKER, P ;
ZANETTI, M ;
DEBATIN, JF ;
MCKINNON, G ;
HODLER, J .
INVESTIGATIVE RADIOLOGY, 1995, 30 (02) :110-114
[12]   Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multidetector CT [J].
Lee, Mi-Jung ;
Kim, Sungjun ;
Lee, Sung-Ah ;
Song, Ho-Taek ;
Huh, Yong-Min ;
Kim, Dae-Hong ;
Han, Seung Hwan ;
Suh, Jin-Suck .
RADIOGRAPHICS, 2007, 27 (03) :791-803
[13]   Quantitative assessment of an MR technique for reducing metal artifact: application to spin-echo imaging in a phantom [J].
Lee, MJ ;
Janzen, DL ;
Munk, PL ;
MacKay, A ;
Xiang, QS ;
McGowen, A .
SKELETAL RADIOLOGY, 2001, 30 (07) :398-401
[14]   Clinical relevance of multislice CT of the spine after osteosynthesis [J].
Lorenzen, M ;
Wedegärtner, U ;
Weber, C ;
Petersen, JP ;
Adam, G ;
Lorenzen, J .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2005, 177 (11) :1540-1544
[15]  
Ludeke K M, 1985, Magn Reson Imaging, V3, P329, DOI 10.1016/0730-725X(85)90397-2
[16]  
Mitchell D. K., 2000, MRI PRINCIPLES, P35
[17]   MR-GUIDED ASPIRATION BIOPSY - NEEDLE DESIGN AND CLINICAL-TRIALS [J].
MUELLER, PR ;
STARK, DD ;
SIMEONE, JF ;
SAINI, S ;
BUTCH, RJ ;
EDELMAN, RR ;
WITTENBERG, J ;
FERRUCCI, JT .
RADIOLOGY, 1986, 161 (03) :605-609
[18]   Orthopedic hardware complications diagnosed with multi-detector row CT [J].
Ohashi, K ;
El-Khoury, GY ;
Bennett, DL ;
Restrepo, JM ;
Berbaum, KS .
RADIOLOGY, 2005, 237 (02) :570-577
[19]   Metal artifact reduction sequence: Early clinical applications [J].
Olsen, RV ;
Munk, PL ;
Lee, MJ ;
Janzen, DL ;
MacKay, AL ;
Xiang, QS ;
Masri, B .
RADIOGRAPHICS, 2000, 20 (03) :699-712
[20]   Optimizing imaging parameters for MR evaluation of the spine with titanium pedicle screws [J].
Petersilge, CA ;
Lewin, JS ;
Duerk, JL ;
Yoo, JU ;
Ghaneyem, AJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 166 (05) :1213-1218