Ultrasound microbubble destruction imaging in acute middle cerebral artery stroke

被引:41
作者
Kern, R [1 ]
Perren, F
Schoeneberger, K
Gass, A
Hennerici, M
Meairs, S
机构
[1] Univ Heidelberg, Univ Klinikum Mannheim, Dept Neurol, D-68135 Mannheim, Germany
[2] CHU Vaudois, Dept Neurol, CH-1011 Lausanne, Switzerland
[3] Univ Basel Hosp, Dept Neurol, CH-4031 Basel, Switzerland
[4] Univ Basel Hosp, Dept Neuroradiol, CH-4031 Basel, Switzerland
关键词
hemodynamics; magnetic resonance imaging; microbubbles; stroke; acute; ultrasonography; Doppler; transcranial;
D O I
10.1161/01.STR.0000129332.10721.7e
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Cerebral perfusion imaging in acute stroke assists in determining the subtype and the severity of ischemia. Recent studies in perfusion models and in healthy volunteers have shown that ultrasound perfusion imaging based on microbubble destruction can be used to assess tissue perfusion. We applied ultrasound microbubble destruction imaging (MDI) to identify perfusion deficits in patients with acute middle cerebral artery (MCA) territory stroke. Methods-Fifteen acute MCA stroke patients with sufficient transtemporal bone windows were investigated with ultrasound MDI and perfusion-weighted MRI (PWI). MDI was performed using power pulse-inversion contrast harmonic imaging. Thirty seconds after a bolus injection of the echo contrast agent SonoVue, microbubbles were destroyed using a series of high-energy pulses. Local perfusion status was analyzed in selected regions of interest by destruction curves and acoustic intensity differences (DeltaI) before and after microbubble destruction. Local perfusion status was then compared with perfusion compromise as identified on PWI. Results-The mean differences of acoustic intensity from the ischemic MCA territory were significantly diminished compared with the normal hemisphere (DeltaI=2.52+/-1.75 versus DeltaI=13.79+/-7.31; P<0.001), resulting in lower slopes of microbubble destruction. PWI confirmed perfusion changes in the selected anatomical regions on time-to-peak maps in all 15 patients. Conclusions-MDI is a qualitative method that can rapidly detect perfusion changes in acute stroke. When combined with other ultrasound techniques and PWI, it may well be valuable in the care of stroke unit patients, eg, as a screening method and for follow-up assessments of perfusion deficits.
引用
收藏
页码:1665 / 1670
页数:6
相关论文
共 16 条
  • [1] Quantitative measurements of second harmonic Doppler using ultrasound contrast agents
    Chang, PH
    Shung, KK
    Levene, HB
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1996, 22 (09) : 1205 - 1214
  • [2] Contrast burst depletion imaging (CODIM) - A new imaging procedure and analysis method for semiquantitative ultrasonic perfusion imaging
    Eyding, J
    Wilkening, W
    Reckhardt, M
    Schmid, G
    Meves, S
    Ermert, H
    Przuntek, H
    Postert, T
    [J]. STROKE, 2003, 34 (01) : 77 - 83
  • [3] Ultrasonic evaluation of pathological brain perfusion in acute stroke using second harmonic imaging
    Federlein, J
    Postert, T
    Meves, S
    Weber, S
    Przuntek, H
    Büttner, T
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2000, 69 (05) : 616 - 622
  • [4] Transmit aperture processing for nonlinear contrast agent imaging
    Krishnan, S
    ODonnell, M
    [J]. ULTRASONIC IMAGING, 1996, 18 (02) : 77 - 105
  • [5] Full-motion pulse inversion power Doppler contrast echocardiography differentiates stunning from necrosis and predicts recovery of left ventricular function after acute myocardial infarction
    Main, ML
    Magalski, A
    Chee, NK
    Coen, MM
    Skolnick, DG
    Good, TH
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 38 (05) : 1390 - 1394
  • [6] Pulse-inversion contrast harmonic imaging: ultrasonographic assessment of cerebral perfusion
    Meairs, S
    Daffertshofer, M
    Neff, W
    Eschenfelder, C
    Hennerici, M
    [J]. LANCET, 2000, 355 (9203) : 550 - 551
  • [7] Transcranial contrast diminution imaging of the human brain: A pilot study in healthy volunteers
    Meyer, K
    Seidel, G
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2002, 28 (11-12) : 1433 - 1437
  • [8] Stimulated acoustic emission detected by transcranial color Doppler ultrasound - A contrast-specific phenomenon useful for the detection of cerebral tissue perfusion
    Pohl, C
    Tiemann, K
    Schlosser, T
    Becher, H
    [J]. STROKE, 2000, 31 (07) : 1661 - 1666
  • [9] Postert T, 2000, STROKE, V31, P1460
  • [10] Quantification of cerebral perfusion with "real-time" contrast-enhanced ultrasound
    Rim, SJ
    Leong-Poi, H
    Lindner, JR
    Couture, D
    Ellegala, D
    Mason, H
    Durieux, M
    Kassel, NF
    Kaul, S
    [J]. CIRCULATION, 2001, 104 (21) : 2582 - 2587