An experimental study on critical velocity in sloping tunnel with longitudinal ventilation under fire

被引:98
作者
Yi, Liang [1 ,2 ]
Xu, Qiqi [1 ]
Xu, Zhisheng [1 ]
Wu, Dexing [3 ]
机构
[1] Cent S Univ, Inst Disaster Prevent Sci & Safety Technol, Changsha, Hunan, Peoples R China
[2] Henan Polytech Univ, Key Lab Gas & Fire Prevent Henan Prov, Jiaozuo, Henan, Peoples R China
[3] Zhejiang Prov Inst Commun Planning Design & Res, Hangzhou, Zhejiang, Peoples R China
关键词
Tunnel fire; Longitudinal ventilation; Slope; Critical velocity; SMOKE FLOW; GAS TEMPERATURE; LAYERING LENGTH; BURNING RATE; POOL FIRE; DISTANCE; MODEL;
D O I
10.1016/j.tust.2014.05.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Experiments based on Froude scaling law were conducted in a 1/10 reduced-scale model tunnel to investigate the effect of slope on critical velocity in tunnel with longitudinal ventilation under fire. Methanol pool fire was used as the fire source. Smoke movement in the model tunnel with different combination of tunnel slope (-3%, -1.8%, -1%, 0%, 1%, 1.8% and 3%) and longitudinal ventilation velocity was studied. The longitudinal distribution of temperature and velocity were measured. Critical longitudinal ventilation velocity for arresting smoke back flowing in the model tunnel was investigated. Critical velocity in horizontal tunnel obtained in this study was used to compare with that of previous studies. The experimental results agreed well with the model proposed by Wu and Bakar. Correlation between the critical velocity and the slope of the tunnel is proposed based on the experiment results. As the tunnel slope increases from downhill to uphill, critical velocity decreases nearly at a rate independent of the heat release rate of the fire source. The correlation proposed in this studied agrees well with the equation adopted in the Subway Environment Simulation Computer Program (SES). However, it has some discrepancy with the expressions proposed by Atkinson and Ko et al. based on their experimental results. The cause of the discrepancy is attributed to different configuration of the experiments. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:198 / 203
页数:6
相关论文
共 31 条
[11]   The critical ventilation velocity in tunnel fires - a computer simulation [J].
Hwang, CC ;
Edwards, JC .
FIRE SAFETY JOURNAL, 2005, 40 (03) :213-244
[12]   Characteristic length scale of critical ventilation velocity in tunnel smoke control [J].
Kang, Kai .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2010, 25 (03) :205-211
[13]   An Experimental Study on the Effect of Slope on the Critical Velocity in Tunnel Fires [J].
Ko, Gwon Hyun ;
Kim, Seung Ryul ;
Ryou, Hong Sun .
JOURNAL OF FIRE SCIENCES, 2010, 28 (01) :27-47
[14]   Simple model for control of fire gases in a ventilated tunnel [J].
Kunsch, JP .
FIRE SAFETY JOURNAL, 2002, 37 (01) :67-81
[15]   Fire properties in near field of square fire source with longitudinal ventilation in tunnels [J].
Kurioka, H ;
Oka, Y ;
Satoh, H ;
Sugawa, O .
FIRE SAFETY JOURNAL, 2003, 38 (04) :319-340
[16]   An experimental study of the effect of the aspect ratio on the critical velocity in longitudinal ventilation tunnel fires [J].
Lee, SR ;
Ryou, HS .
JOURNAL OF FIRE SCIENCES, 2005, 23 (02) :119-138
[17]   Experimental study of smoke spread in titled urban traffic tunnels fires [J].
Li Junmei ;
Liu Shanshan ;
Li Yanfeng ;
Chen Chao ;
Liu Xuan ;
Yin Chenchen .
2012 INTERNATIONAL SYMPOSIUM ON SAFETY SCIENCE AND TECHNOLOGY, 2012, 45 :690-694
[18]   Fire-induced flow temperature along tunnels with longitudinal ventilation [J].
Li, Liming ;
Li, Sen ;
Wang, Xuegui ;
Zhang, Heping .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2012, 32 :44-51
[19]   The maximum temperature of buoyancy-driven smoke flow beneath the ceiling in tunnel fires [J].
Li, Ying Zhen ;
Lei, Bo ;
Ingason, Haukur .
FIRE SAFETY JOURNAL, 2011, 46 (04) :204-210
[20]   Study of critical velocity and backlayering length in longitudinally ventilated tunnel fires [J].
Li, Ying Zhen ;
Lei, Bo ;
Ingason, Haukur .
FIRE SAFETY JOURNAL, 2010, 45 (6-8) :361-370