Oxidation of dissolved organic matter in the effluent of a sewage treatment plant using ozone combined with hydrogen peroxide (O3/H2O2)

被引:48
|
作者
Rosal, Roberto [1 ]
Rodriguez, Antonio [1 ]
Antonio Perdigon-Melon, Jose [1 ]
Petre, Alice [1 ]
Garcia-Calvo, Eloy [1 ]
机构
[1] Univ Alcala de Henares, Dept Chem Engn, Alcala De Henares 28771, Spain
关键词
Ozonation; Hydrogen peroxide; Advanced oxidation processes; water pollution control; Water reuse; Kinetics; IMPERATIVE TECHNOLOGIES; AQUEOUS-SOLUTION; WATER; PHARMACEUTICALS; OZONATION; TOXICITY; KINETICS; DEGRADATION; REMOVAL; DECOMPOSITION;
D O I
10.1016/j.cej.2008.11.019
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The effluent from the secondary clarifier of an Urban Sewage Treatment Plant was oxidized by the combined and simultaneous use of ozone and hydrogen peroxide. The purpose was to increase the wastewater's reuse potential by improving water quality. The removal of dissolved organic chemicals was enhanced by adding periodic pulses of hydrogen peroxide while keeping pH above 8.0 throughout the runs. These conditions led to almost complete mineralization in less than 1 h. Under similar conditions, without the addition of hydrogen peroxide, the removal of total organic carbon (TOC) was no higher than 35%. The evolution of TOC was related to the concentration of hydroxyl radicals using a second-order kinetic model in which the exposure to hydroxyl radical was included by assuming a quasi-steady-state approximation. The concentration of hydroxyl radical was computed using the experimental data from ozone and hydrogen peroxide. The kinetic constants for the hydroxyl-mediated mineralization process were determined for wastewaters collected during a 1-year sampling campaign. The results showed that the mineralization process takes place in two periods whose rate constants were linked to the chemical oxygen demand (COD) to biochemical oxygen demand (BOD) ratio and to the chloride content of wastewaters. During the first part of the runs, the specific rate of mineralization was high, before subsequently decreasing after a period of 5-15 min by an average factor of 6.4 whose 95% confidence interval was in the 3.4-9.3 range. The moles of TOC removed per mole of ozone consumed were in the range of 9.2-17.7 mg O-3/mg TOC measured at maximum ozone efficiency, which always occurred within the first 10 min. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:311 / 318
页数:8
相关论文
共 50 条
  • [21] Oxidation of microplastics by O3 and O3/H2O2: Surface modification and adsorption capacity
    de Aragao Bele, Tiago Gomes
    Neves, Tauany F.
    Cristale, Joyce
    Prediger, Patricia
    Constapel, Marc
    Dantas, Renato F.
    JOURNAL OF WATER PROCESS ENGINEERING, 2021, 41
  • [22] O3 and O3/H2O2 treatment of sulfonamide and macrolide antibiotics in wastewater
    Lin, Angela Yu-Chen
    Lin, Cheng-Fang
    Chiou, Jia-Ming
    Hong, P. K. Andy
    JOURNAL OF HAZARDOUS MATERIALS, 2009, 171 (1-3) : 452 - 458
  • [23] Pretreatment on petrochemical secondary effluent refractory organic wastewater by O3/UV/H2O2 technology
    Zhang, Chao
    Wu, Fuping
    Wang, Qian
    Zhang, Guozhen
    Liu, Meng
    Yang, Hao
    ADVANCES IN ENERGY SCIENCE AND EQUIPMENT ENGINEERING, 2015, : 895 - 898
  • [24] O3、O3/H2O2、O3/H2O2/UV去除水中六氯苯的研究
    王华
    吕锡武
    杨开明
    江元霞
    给水排水, 2007, (05) : 136 - 138
  • [25] Oxidation of natural organic matter with processes involving O3, H2O2 and UV light: formation of oxidation and disinfection by-products
    Agbaba, Jasmina
    Jazic, Jelena Molnar
    Tubic, Aleksandra
    Watson, Malcolm
    Maletic, Snezana
    Isakovski, Marijana Kragulj
    Dalmacija, Bozo
    RSC ADVANCES, 2016, 6 (89): : 86212 - 86219
  • [26] Removal of organic contamination in planting wastewater by O3 and O3/H2O2 processes
    Yang, Yue-Ping
    Xu, Xinh-Hua
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [27] Reaction of aqueous iodide at high concentration with O3 and O3/H2O2 in the presence of natural organic matter: implications for drinking water treatment
    Lee, Hye-Jin
    Kim, Hak-Hyeon
    Lee, Hongshin
    Lee, Changha
    ENVIRONMENTAL CHEMISTRY LETTERS, 2015, 13 (04) : 453 - 458
  • [28] Impact of O3 or O3/H2O2 treatment via a membrane contacting system on the composition and characteristics of the natural organic matter of surface waters
    Stylianos K. Stylianou
    Ioannis A. Katsoyiannis
    Mathias Ernst
    Anastasios I. Zouboulis
    Environmental Science and Pollution Research, 2018, 25 : 12246 - 12255
  • [29] Reaction of aqueous iodide at high concentration with O3 and O3/H2O2 in the presence of natural organic matter: implications for drinking water treatment
    Hye-Jin Lee
    Hak-Hyeon Kim
    Hongshin Lee
    Changha Lee
    Environmental Chemistry Letters, 2015, 13 : 453 - 458
  • [30] Impact of O3 or O3/H2O2 treatment via a membrane contacting system on the composition and characteristics of the natural organic matter of surface waters
    Stylianou, Stylianos K.
    Katsoyiannis, Ioannis A.
    Ernst, Mathias
    Zouboulis, Anastasios I.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2018, 25 (13) : 12246 - 12255