Determination of stable lead isotope ratios in environmental samples: Combination of microwave digestion and ICP-MS

被引:4
|
作者
Kawamura, H [1 ]
Tagomori, H
Matsuoka, N
Takashima, Y
Tawaki, S
Momoshima, N
机构
[1] Kyushu Environm Evaluat Assoc, Higashi Ku, Fukuoka 8130004, Japan
[2] Kyushu Univ, Fac Sci, Dept Chem, Higashi Ku, Fukuoka 8120053, Japan
[3] Kyushu Univ, Inst Environm Sci, Higashi Ku, Fukuoka 8120053, Japan
[4] Kyushu Elect Power Co Inc, Res Lab, Environm Engn Grp, Minami Ku, Fukuoka 8150032, Japan
关键词
D O I
10.1007/BF02347384
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Microwave digestion was applied as pretreatment of environmental samples for the determination of lead isotope ratios by ICP-MS. Microwave digestion decomposed the samples easily and rapidly without lead contamination. The lead isotope ratios could be measured directly by ICP-MS without tedious lead purification, because the influence of the matrix elements on measurements of lead isotope ratios is small enough to be ignored.
引用
收藏
页码:717 / 720
页数:4
相关论文
共 50 条
  • [41] Determination of selenium in the commercially bottled drinking water by ICP-MS - Determination of trace elements in environmental samples by ICP-MS .4.
    Naohara, J
    Yamashita, E
    JOURNAL OF THE JAPANESE SOCIETY FOR FOOD SCIENCE AND TECHNOLOGY-NIPPON SHOKUHIN KAGAKU KOGAKU KAISHI, 1996, 43 (10): : 1133 - 1137
  • [42] A new method for determining 236U/238U isotope ratios in environmental samples by means OF ICP-MS/MS
    Diez-Fernandez, Silvia
    Jaegler, Hugo
    Bresson, Carole
    Chartier, Frederic
    Evrard, Olivier
    Hubert, Amelie
    Nonell, Anthony
    Pointurier, Fabien
    Isnard, Helene
    TALANTA, 2020, 206 (206)
  • [43] Determination of lead isotope ratios in crude oils with Q-ICP/MS
    Dreyfus, S.
    Pecheyran, C.
    Lienemann, C. P.
    Magnier, C.
    Prinzhofer, A.
    Donard, O. F. X.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (04) : 351 - 360
  • [44] Accurate determination of sulfur in gasoline and related fuel samples using isotope dilution ICP-MS with direct sample injection and microwave-assisted digestion
    Heilmann, J
    Boulyga, SF
    Heumann, KG
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 380 (02) : 190 - 197
  • [45] Evaluation and Comparison between a Conventional Acid Digestion Method and a Microwave Digestion System for Heavy Metals Determination in Mentha Samples by ICP-MS
    Alsehli, Bandar R. M.
    EGYPTIAN JOURNAL OF CHEMISTRY, 2021, 64 (02): : 869 - 881
  • [46] EDXRF and ICP-MS analysis of environmental samples
    Nguyen, TH
    Boman, J
    Leermakers, M
    X-RAY SPECTROMETRY, 1998, 27 (04) : 265 - 276
  • [47] EDXRF and ICP-MS Analysis of Environmental Samples
    Physics and Engineering Physics, Chalmers University of Technology, S-412 96 Gothenburg, Sweden
    不详
    不详
    X-Ray Spectrom., 4 (265-276):
  • [48] Determination of Pb isotope ratios using multiple collector ICP-MS and Tl normalization
    He, XX
    Zhu, XK
    Yang, C
    Tang, SH
    Chai, JJ
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2004, 68 (11) : A541 - A541
  • [49] Microwave-assisted Digestion of Environmental Soil Sample and Measurement of Plutonium by ICP-MS
    Xu H.
    Ma T.
    Li D.
    Zhan J.
    Wang Y.
    Wang B.
    Wang Y.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2019, 53 (04): : 603 - 610
  • [50] Direct determination of halogens in powdered geological and environmental samples using isotope dilution laser ablation ICP-MS
    Boulyga, SF
    Heumann, KG
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2005, 242 (2-3) : 291 - 296