Customized, Automated Stimulus Location Choice for Assessment of Visual Field Defects

被引:32
|
作者
Chong, Luke X. [1 ]
McKendrick, Allison M. [1 ]
Ganeshrao, Shonraj B. [1 ,2 ]
Turpin, Andrew [2 ]
机构
[1] Univ Melbourne, Dept Optometry & Vis Sci, Melbourne, Vic, Australia
[2] Univ Melbourne, Dept Comp & Informat Syst, Melbourne, Vic, Australia
基金
澳大利亚研究理事会;
关键词
computer simulation; perimetry; algorithms; visual fields; FUNDUS-ORIENTED PERIMETRY; ADAPTIVE PROGRAM SAPRO; LOCALLY CONDENSED GRIDS; TEST-RETEST VARIABILITY; NERVE-FIBER LAYER; RELIABILITY INDEXES; RESOLUTION PERIMETRY; OCULAR HYPERTENSION; OPTIC NEURITIS; FULL-THRESHOLD;
D O I
10.1167/iovs.13-13761
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To introduce a perimetric algorithm (gradient-oriented automated natural neighbor approach [GOANNA]) that automatically chooses spatial test locations to improve characterization of visual field (VF) loss without increasing test times. METHODS. Computer simulations were undertaken to assess the performance of GOANNA. GOANNA was run on a 3 degrees grid of 150 locations, and was compared with a zippy estimation by sequential testing (ZEST) thresholding strategy for locations in the 24-2 test pattern, with the remaining 98 locations being interpolated. Simulations were seeded using empirical data from 23 eyes with glaucoma that were measured at all 150 locations. The performance of the procedures was assessed by comparing the output thresholds to the input thresholds (accuracy and precision) and by evaluating the number of presentations required for the procedure to terminate (efficiency). RESULTS. When collated across whole-fields, there was no significant difference in accuracy, precision, or efficiency between GOANNA and ZEST. However, GOANNA targeted presentations on scotoma borders; hence it was more precise and accurate at locations where the sensitivity gradient within the VF was high. CONCLUSIONS. Compared with ZEST, GOANNA was marginally less precise in areas of the VF that had spatially uniform sensitivity, but improved accuracy and precision in regions surrounding scotoma edges. GOANNA provides a principled framework for automatic placement of additional test locations to provide spatially denser testing around the borders of VF loss.
引用
收藏
页码:3265 / 3274
页数:10
相关论文
共 50 条
  • [1] Automated stimulus choice in condensed grids for assessment of visual field defects
    Chong, Luke
    McKendrick, Allison
    Turpin, Andrew
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [2] Choice of Stimulus Range and Size Can Reduce Test-Retest Variability in Glaucomatous Visual Field Defects
    Swanson, William H.
    Horner, Douglas G.
    Dul, Mitchell W.
    Malinovsky, Victor E.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2014, 3 (05):
  • [3] LOCATION OF EARLY GLAUCOMATOUS VISUAL-FIELD DEFECTS
    NICHOLAS, SP
    WERNER, EB
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1980, 15 (03): : 131 - 133
  • [4] Visual field defects in pre-perimetric glaucoma identified by customized oct - guided white-on-white automated perimetry
    Magouritsas, G.
    Georgiadis, O.
    Portaliou, D. M.
    Moschonas, K.
    ACTA OPHTHALMOLOGICA, 2014, 92
  • [5] Customized Visual Discrimination Digital Therapy According to Visual Field Defects in Chronic Stroke Patients
    Namgung, Eun
    Kim, Hana
    Kim, Yong-Hwan
    Kim, Young-Sun
    Lee, Eun-Jae
    Lee, Jee-Hyun
    Sasaki, Yuka
    Watanabe, Takeo
    Kang, Dong-Wha
    JOURNAL OF CLINICAL NEUROLOGY, 2024, 20 (05): : 509 - 518
  • [6] Automated assessment of stato-kinetic dissociation (SKD) in advanced visual field defects.
    Schiller, J
    Schiefer, U
    Paetzold, J
    Benda, N
    Vonthein, R
    Dietz, K
    Dietrich, TJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2000, 41 (04) : S295 - S295
  • [7] Location of Initial Visual Field Defects in Glaucoma and Their Modes of Deterioration
    Kim, Joon Mo
    Kyung, Haksu
    Shim, Seong Hee
    Azarbod, Parham
    Caprioli, Joseph
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (13) : 7956 - 7962
  • [8] QUANTIFICATION OF GLAUCOMATOUS VISUAL-FIELD DEFECTS WITH AUTOMATED PERIMETRY
    FLAMMER, J
    DRANCE, SM
    AUGUSTINY, L
    FUNKHOUSER, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1985, 26 (02) : 176 - 181
  • [9] REPRODUCIBILITY OF VISUAL-FIELD DEFECTS DETECTED ON AUTOMATED PERIMETRY
    KATZ, J
    SOMMER, A
    QUIGLEY, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1991, 32 (04) : 917 - 917
  • [10] VISUALLY EVOKED-POTENTIALS TO CHECKERBOARD PATTERNS - INFLUENCE OF RETINAL LOCATION OF THE STIMULUS IN NORMALS AND IN CHILDREN WITH VISUAL-FIELD DEFECTS
    WENZEL, D
    BRANDL, U
    ALBERT, F
    EUROPEAN JOURNAL OF PEDIATRICS, 1981, 135 (03) : 339 - 339