Management of recurrent anastomotic stricture and iatrogenic stenosis by circular stapler

被引:19
作者
Rees, JRE [1 ]
Carney, L [1 ]
Gill, TS [1 ]
Dixon, AR [1 ]
机构
[1] N Bristol NHS Trust, Dept Colorectal Surg, Bristol, Avon, England
关键词
colorectal anastomosis; anastomotic stricture; circular stapler;
D O I
10.1007/s10350-004-0518-y
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Anastomotic stricture is an increasingly common clinical finding. It is thought to arise because of ischemia, disruption, or leakage at an anastomosis site. Its management can be difficult and strictures often are resistant to standard dilation therapy. Major corrective surgery is possible; however, it is technically challenging and not without risk. We have used a circular stapler to excise colorectal strictures, introducing the anvil of the stapler via a proximal stoma or colotomy, drawing the anvil through the stricture with a snare via a colonoscope and affixing it to the body of a circular staple gun and excising the stricture. We have with found this to be an effective treatment in appropriately selected patients.
引用
收藏
页码:944 / 947
页数:4
相关论文
共 12 条
  • [1] THE EXPERIMENTAL BASIS OF INTESTINAL SUTURING - EFFECT OF SURGICAL TECHNIQUE, INFLAMMATION, AND INFECTION ON ENTERIC WOUND-HEALING
    BALLANTYNE, GH
    [J]. DISEASES OF THE COLON & RECTUM, 1984, 27 (01) : 61 - 71
  • [2] RANDOMIZED PROSPECTIVE EVALUATION OF THE EEA STAPLER FOR COLORECTAL ANASTOMOSES
    BEART, RW
    KELLY, KA
    [J]. AMERICAN JOURNAL OF SURGERY, 1981, 141 (01) : 143 - 147
  • [3] ENDOSCOPIC DILATION OF ANASTOMOTIC COLONIC STENOSIS BY DIFFERENT TECHNIQUES - AN ALTERNATIVE TO SURGERY
    BEDOGNI, G
    RICCI, E
    PEDRAZZOLI, C
    CONIGLIARO, R
    BARBIERI, I
    BERTONI, G
    CONTINI, S
    SERAFINI, G
    [J]. GASTROINTESTINAL ENDOSCOPY, 1987, 33 (01) : 21 - 24
  • [4] BRAIN J, 1981, SURGERY, V89, P271
  • [5] Gentilli S, 1999, Minerva Chir, V54, P905
  • [6] COLORECTAL ANASTOMOTIC STENOSIS - RESULTS OF A SURVEY OF THE ASCR MEMBERSHIP
    LUCHTEFELD, MA
    MILSOM, JW
    SENAGORE, A
    SURRELL, JA
    MAZIER, WP
    [J]. DISEASES OF THE COLON & RECTUM, 1989, 32 (09) : 733 - 736
  • [7] OVERY RD, 1980, BRIT J SURG, V67, P363
  • [8] POLGLASE AL, 1981, SURG GYNECOL OBSTET, V152, P792
  • [9] INTRAMURAL PH - A QUANTITATIVE MEASUREMENT FOR PREDICTING COLORECTAL ANASTOMOTIC HEALING
    SENAGORE, A
    MILSOM, JW
    WALSHAW, RK
    DUNSTAN, R
    MAZIER, WP
    CHAUDRY, IH
    [J]. DISEASES OF THE COLON & RECTUM, 1990, 33 (03) : 175 - 179
  • [10] A new device for the treatment of coloproctostomic stricture after double stapling anastomoses
    Shimada, S
    Matsuda, M
    Uno, K
    Matsuzaki, H
    Murakami, S
    Ogawa, M