Comparison of liquid chromatography mass spectrometry interfaces for the analysis of polar metabolites of benzo[a]pyrene

被引:19
|
作者
Koeber, R
Niessner, R
Bayona, JM
机构
[1] TECH UNIV MUNICH,INST HYDROCHEM,D-81377 MUNICH,GERMANY
[2] CID,CSIC,DEPT ENVIRONM CHEM,E-08034 BARCELONA,SPAIN
来源
关键词
D O I
10.1007/s002160050571
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of two liquid chromatography-mass spectrometry (LC/MS) interfacing techniques, thermospray (TSP) and atmospheric pressure chemical ionization (APCI), for the analysis of benzo[a]pyrene (BaP) metabolites (hydroxy, epoxy and quinone derivatives) was compared. Interface and detection parameters such as source temperature, eluent composition or flow rate were optimized using negative ion mode. In TSP, the main ions are mostly [M](-), [M - H2O](-) or [M + CH3COO](-), whereas APCI gives mainly the [M](-) and [M - H](-) ions. Quantification was carried out by flow injection. Calibration graphs were linear in the range of 10 ng to 1000 ng in TSP and 0.1 ng to 10 ng in APCI. Detection limits were in the range of 1 ng to 20 ng in TSP and 0.002 ng to 0.2 ng in APCI. The presence of BaP-1,6-dione, BaP-3,6-dione, and BaP-6,12-dione was confirmed in environmental samples of air particulate matter.
引用
收藏
页码:267 / 273
页数:7
相关论文
共 50 条