Flexural behavior of rectangular FRP-tubes filled with reinforced concrete: Experimental and theoretical studies

被引:30
作者
Abouzied, Ahmed [1 ]
Masmoudi, Radhouane [2 ]
机构
[1] Helwan Univ, Dept Civil Engn, Fac Engn Elmattareya, Cairo, Egypt
[2] Univ Sherbrooke, Dept Civil Engn, Sherbrooke, PQ J1K 2R1, Canada
关键词
Beams; Fiber-reinforced polymer (FRP); Concrete filled FRP tubes; Flexural behavior; Deflection; Theoretical predictions; COMPOSITE TUBES; CONFINED CONCRETE; POLYMER TUBES; COLUMNS; PERFORMANCE; STEEL; DESIGN; MANUFACTURE;
D O I
10.1016/j.engstruct.2016.12.010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents experimental and theoretical investigations on the flexural behavior of rectangular concrete-filled fiber-reinforced polymer (FRP) tube (CFFT) beams with steel rebar. Seven full-scale CFFT beams, 3200 mm long and 305 x 406 mm(2) cross section, were tested udder a four-point bending load and were compared to two control steel-reinforced concrete (RC) beams. The CFFT beams had the same flexural steel reinforcement, but they had different wall thicknesses of filament-wound FRP tubes. The experimental results indicate an outstanding performance of the CFFT beams in terms of strength and energy absorption compared to the RC beams since their flexural strength and energy attained values 344% and 1052% higher than that of the RC beams, respectively. A strain compatibility equilibrium model was developed to predict the moment-curvature response of the CFFT section addressing the issue of confinement and tension stiffening of concrete. The analytical results match well the experimental results in terms of moments, curvature, strains, and neutral axis location. Based on the model, the deflection can be predicted by integrating the curvatures along the span of the flexural member. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:59 / 73
页数:15
相关论文
共 39 条
  • [1] AASHTO, 2012, GUID SPEC DES CONCR
  • [2] Abouzied A, 2014, P 4 INT STRUCT SPEC
  • [3] Abouzied A, 2012, P 11 INT S FIB REINF
  • [4] Abouzied A, 2013, P 2 C SMART MON ASS
  • [5] Structural performance of new fully and partially concrete-filled rectangular FRP-tube beams
    Abouzied, Ahmed
    Masmoudi, Radhouane
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2015, 101 : 652 - 660
  • [6] [Anonymous], 2014, Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14). ACI 318-14
  • [7] [Anonymous], 2004, STANDARD TEST METHOD
  • [8] [Anonymous], D695 ASTM
  • [9] [Anonymous], 2012, C39 ASTM
  • [10] ASTM, 2009, A615A615M ASTM