Hybrid adaptive radiotherapy with on-line MRI in cervix cancer IMRT

被引:51
|
作者
Oh, Seungjong [1 ]
Stewart, James [1 ,3 ]
Moseley, Joanne [1 ]
Kelly, Valerie [1 ,2 ]
Lim, Karen [6 ]
Xie, Jason [1 ]
Fyles, Anthony [1 ,2 ]
Brock, Kristy K. [1 ,2 ,4 ]
Lundin, Anna [5 ]
Rehbinder, Henrik [5 ]
Milosevic, Michael [1 ,2 ]
Jaffray, David [1 ,2 ,3 ,4 ]
Cho, Young-Bin [1 ,2 ]
机构
[1] Univ Hlth Network, Princess Margaret Canc Ctr, Radiat Med Program, Toronto, ON, Canada
[2] Univ Toronto, Dept Radiat Oncol, Toronto, ON M5S 1A1, Canada
[3] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON M5S 1A1, Canada
[4] Univ Toronto, Dept Med Biophys, Toronto, ON M5S 1A1, Canada
[5] RaySearch Labs AB, Stockholm, Sweden
[6] Liverpool Hosp, Dept Radiat Oncol, Sydney, NSW, Australia
关键词
Adaptive radiotherapy; MR image guidance; Soft tissue matching; Dose accumulation; Cost and benefit; INTENSITY-MODULATED RADIOTHERAPY; RADIATION-THERAPY; ACCURACY; TOXICITY; IMPACT; TUMOR; WOMEN;
D O I
10.1016/j.radonc.2013.11.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Substantial organ motion and tumor shrinkage occur during radiotherapy for cervix cancer. IMRT planning studies have shown that-the quality of radiation delivery is influenced by these anatomical changes, therefore the adaptation of treatment plans may be warranted. Image guidance with off-line replanning, i.e. hybrid-adaptation, is recognized as one of the most practical adaptation strategies. In this study, we investigated the effects of soft tissue image guidance using on-line MR while varying the frequency of off-line replanning on the adaptation of cervix IMRT. Materials and method: 33 cervical cancer patients underwent planning and weekly pelvic MRI scans during radiotherapy. 5 patients of 33 were identified in a previous retrospective adaptive planning study, in which the coverage of gross tumor volume/clinical target volume (GTV/CTV) was not acceptable given single off-line IMRT replan using a 3 mm PTV margin with bone matching. These 5 patients and a randomly selected 10 patients from the remaining 28 patients, a total of 15 patients of 33, were considered in this study. Two matching methods for image guidance (bone to bone and soft tissue to dose matrix) and three frequencies of off-line replanning (none, single, and weekly) were simulated and compared with respect to target coverage (cervix, GTV, lower uterus, parametrium, upper vagina, tumor related CTV and elective lymph node CTV) and OAR sparing (bladder, bowel, rectum, and sigmoid). Cost (total process time) and benefit (target coverage) were analyzed for comparison. Results: Hybrid adaptation (image guidance with off-line replanning) significantly enhanced target coverage for both 5 difficult and 10 standard cases. Concerning image guidance, bone matching was short of delivering enough doses for 5 difficult cases even with a weekly off-line replan. Soft tissue image guidance proved successful for all cases except one when single or more frequent replans were utilized in the difficult cases. Cost and benefit analysis preferred (soft tissue) image guidance over (frequent) off-line replanning. Conclusions: On-line MRI based image guidance (with combination of dose distribution) is a crucial element for a successful hybrid adaptive radiotherapy. Frequent off-line replanning adjuvantly enhances adaptation quality. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:323 / 328
页数:6
相关论文
共 50 条
  • [41] MRI guided online adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion in patients with cervical cancer
    Ding, Shouliang
    Piao, Zun
    Chen, Meining
    Li, Fanghua
    Li, Yongbao
    Liu, Biaoshui
    Liu, Hongdong
    Huang, Xiaoyan
    Li, Junyun
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2025, 50
  • [42] A DVH-guided IMRT optimization algorithm for automatic treatment planning and adaptive radiotherapy replanning
    Zarepisheh, Masoud
    Long, Troy
    Li, Nan
    Tian, Zhen
    Romeijn, H. Edwin
    Jia, Xun
    Jiang, Steve B.
    MEDICAL PHYSICS, 2014, 41 (06)
  • [43] Comparison of toxicity after IMRT and 3D-conformal radiotherapy for patients with pancreatic cancer - A systematic review
    Bittner, Martin-Immanuel
    Grosu, Anca-Ligia
    Brunner, Thomas B.
    RADIOTHERAPY AND ONCOLOGY, 2015, 114 (01) : 117 - 121
  • [44] Moderately hypofractionated radiotherapy for localized prostate cancer Long-term outcome using IMRT and volumetric IGRT
    Guckenberger, M.
    Lawrenz, I.
    Flentje, M.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2014, 190 (01) : 48 - 53
  • [45] Magnetic resonance imaging for assessment of parametrial tumour spread and regression patterns in adaptive cervix cancer radiotherapy
    Schmid, Maximilian P.
    Fidarova, Elena
    Poetter, Richard
    Petric, Primoz
    Bauer, Veronika
    Woehs, Veronika
    Georg, Petra
    Kirchheiner, Kathrin
    Berger, Daniel
    Kirisits, Christian
    Doerr, Wolfgang
    Dimopoulos, Johannes C. A.
    ACTA ONCOLOGICA, 2013, 52 (07) : 1384 - 1390
  • [46] Five-year survival outcomes of intensity-modulated radiotherapy with simultaneous integrated boost (IMRT-SIB) using forward IMRT or Tomotherapy for breast cancer
    Lee, Hsin-Hua
    Chen, Chien-Hung
    Luo, Kuei-Hau
    Chuang, Hung-Yi
    Huang, Chih-Jen
    Cheng, Yuan-Kai
    Chen, Frank
    Kuo, Shih-Hsun
    Huang, Ming-Yii
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [47] Towards automated on-line adaptation of 2-Step IMRT plans: QUASIMODO phantom and prostate cancer cases
    Holubyev, Kostyantyn
    Bratengeier, Klaus
    Gainey, Mark
    Polat, Buelent
    Flentje, Michael
    RADIATION ONCOLOGY, 2013, 8
  • [48] Comparative dosimetry of three-phase adaptive and non-adaptive dose-painting IMRT for head-and-neck cancer
    Olteanu, Luiza A. M.
    Berwouts, Dieter
    Madani, Indira
    De Gersem, Werner
    Vercauteren, Tom
    Duprez, Frederic
    De Neve, Wilfried
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 (03) : 348 - 353
  • [49] Comparison of intensity-modulated radiotherapy, adaptive radiotherapy proton radiotherapy, and adaptive proton radiotherapy for treatment of locally advanced head and neck cancer
    Simone, Charles B., II
    Ly, David
    Dan, Tu D.
    Ondos, John
    Ning, Holly
    Belard, Arnaud
    O'Connell, John
    Miller, Robert W.
    Simone, Nicole L.
    RADIOTHERAPY AND ONCOLOGY, 2011, 101 (03) : 376 - 382
  • [50] On-line MR imaging for dose validation of abdominal radiotherapy
    Glitzner, M.
    Crijns, S. P. M.
    de Senneville, B. Denis
    Kontaxis, C.
    Prins, F. M.
    Lagendijk, J. J. W.
    Raaymakers, B. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (22): : 8869 - 8883