Evaluation of blood flow velocity waveform in common carotid artery using multi-branched arterial segment model of human arteries

被引:9
作者
Masuda, M. [1 ]
Emoto, T. [2 ]
Suzuki, A. [3 ]
Akutagawa, M. [2 ]
Kitawaki, T. [4 ]
Kitaoka, K. [5 ]
Tanaka, H. [6 ,7 ]
Obara, S. [8 ]
Yoshizaki, K. [5 ]
Konaka, S. [2 ]
Kinouchi, Y. [2 ]
机构
[1] Univ Tokushima, Grad Sch Adv Technol & Sci, Tokushima 7708506, Japan
[2] Univ Tokushima, Inst Sci & Technol, Tokushima 7708506, Japan
[3] Arabian Oil Co Ltd, Tokyo, Japan
[4] Okayama Univ, Dept Hlth Sci, Okayama 7008558, Japan
[5] Univ Tokushima, Grad Sch, Inst Hlth Biosci, Tokushima 7708503, Japan
[6] Naruto Univ Educ, Fac Hlth, Tokushima 7728502, Japan
[7] Naruto Univ Educ, Living Sci Dept, Tokushima 7728502, Japan
[8] Univ Tokushima, Inst Socio Arts & Sci, Tokushima 7708506, Japan
关键词
Common carotid; Hemodynamics; Fluid simulation; Artery segments model; Artery elasticity; ANKLE VASCULAR INDEX; AGE-RELATED-CHANGES; COMPUTER-SIMULATION; PRESSURE; REFLECTION; STIFFNESS; WILLIS; CIRCLE; TRANSMISSION; DYNAMICS;
D O I
10.1016/j.bspc.2013.05.005
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Arteriosclerosis is considered to be a major cause of cardiovascular diseases, which account for approximately 30% of the causes of death in the world. We have recently demonstrated a strong correlation between arteriosclerosis (arterial elasticity) and two characteristics: maximum systolic velocity (Si) and systolic second peak velocity (S2) of the common carotid artery flow velocity waveform (CCFVW). The CCFVW can be measured by using a small portable measuring device. However, there is currently no theoretical evidence supporting the causes of the relation between CCFVW and arterial elasticity, or the origin of the CCFVW characteristics. In this study, the arterial blood flow was simulated using a one-dimensional systemic arterial segments model of human artery in order to conduct a qualitative evaluation of the relationship between arterial elasticity and the characteristics of CCFVW. The simulation was carried out based on the discretized segments with the physical properties of a viscoelastic tube (the cross-sectional area at the proximal and terminal ends, the length, and the compliance per unit area of the tube (C-S)). The findings obtained through this study revealed that the simulated CCFVW had shape similar characteristics to that of the measured CCFVW. Moreover, when the compliance C-S of the model was decreased, the first peak of the simulated-CCFVW decreased and the second peak increased. Further, by separating the anterograde pulse wave and the reflected pulse wave, which form the CCFVW, we found that the decrease in the first peak of the simulated CCFVW was due to the arrival of a reflected pulse wave from the head after the common carotid artery toward the arrival of a anterograde pulse wave ejected directly from the heart and that the increase in the second peak resulted from the arrival of the peak of the reflected pulse wave from the thoracic aorta. These results establish that the CCFVW characteristics contribute to the assessment of arterial elasticity. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:509 / 519
页数:11
相关论文
共 61 条
[1]   Modelling the circle of Willis to assess the effects of anatomical variations and occlusions on cerebral flows [J].
Alastruey, J. ;
Parker, K. H. ;
Peiro, J. ;
Byrd, S. M. ;
Sherwin, S. J. .
JOURNAL OF BIOMECHANICS, 2007, 40 (08) :1794-1805
[2]  
Aoyama K., 2012, 2012 IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI), P655, DOI 10.1109/BHI.2012.6211668
[3]  
Azhim Azran, 2006, International Conference on Biomedical and Pharmaceutical Engineering 2006. ICBPE 2006, P517
[4]  
Azhim A., 2007, Journal of Biomedical Pharmaceutical Engineering, V1, P17
[5]  
Azran A, 2004, P ANN INT IEEE EMBS, V26, P3708
[6]  
BERGEL DH, 1960, THESIS U LONDON
[7]   Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients [J].
Blacher, J ;
Asmar, R ;
Djane, S ;
London, GM ;
Safar, ME .
HYPERTENSION, 1999, 33 (05) :1111-1117
[8]   A NONINVASIVE METHOD TO ESTIMATE WALL SHEAR RATE USING ULTRASOUND [J].
BRANDS, PJ ;
HOEKS, APG ;
HOFSTRA, L ;
RENEMAN, RS .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (02) :171-185
[9]  
Burton A.C., 1965, PHYSL BIOPHYSICS CIR
[10]   Guidelines for the ultrasound assessment of endothelial-dependent flow-mediated vasodilation of the brachial artery - A report of the International Brachial Artery Reactivity Task Force [J].
Corretti, MC ;
Anderson, TJ ;
Benjamin, EJ ;
Celermajer, D ;
Charbonneau, F ;
Creager, MA ;
Deanfield, J ;
Drexler, H ;
Gerhard-Herman, M ;
Herrington, D ;
Vallance, P ;
Vita, J ;
Vogel, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (02) :257-265