An Improved Processing Method for Breast Whole-Mount Serial Sections for Three-Dimensional Histopathology Imaging

被引:22
作者
Sun, Laibao
Wang, Dan
Zubovits, Judit T. [1 ]
Yaffe, Martin J. [2 ]
Clarke, Gina M. [1 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Dept Pathol, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON M5S 1A1, Canada
基金
加拿大创新基金会;
关键词
Microwave; Histology processing; 3-D Histopathology imaging; Breast cancer; Whole-mount sections; CARCINOMA IN-SITU; MICROWAVE FIXATION; FORMALIN FIXATION; TISSUE FIXATION; MARGIN STATUS; CANCER; QUALITY; THROUGHPUT; SPECIMENS; ROUTINE;
D O I
10.1309/AJCPVBZZ4IKJHY3U
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
To develop and validate improved processing methods for producing diagnostic-quality, whole-mount serial sections for 3-dimensional imaging of whole-breast histopathologic studies, we subjected 4-mm-thick whole-specimen slices to a 38-hour microwave-assisted protocol. Morphologic features, antigenicity, and tissue shrinkage were evaluated A schedule using the tissue processor was optimized by evaluating the serial section yield for 3 schedules. The microwave-based processing schedule is adequate for producing diagnostic-quality whole-mount breast serial sections of an area tip to 6, 000 mm(2) and is compatible with a variety of immunohistochemical stains. A mean +/- SE total tissue shrinkage of 8.4% +/- 0.2% resulted For the tissue processor, optimal results are obtained using a 59-hour schedule. Total fixation and processing time for whole-mount serial breast sections has been reduced from 21 days to 38 hours, with microwave assistance, and to 59 hours without. No adverse effects of microwaves on morphologic features, antigenicity, or gross tissue dimensions were observed
引用
收藏
页码:383 / 392
页数:10
相关论文
共 58 条
[1]   Sampling of grossly benign breast reexcisions - A multidisciplinary approach to assessing adequacy [J].
Abraham, SC ;
Fox, K ;
Fraker, D ;
Solin, L ;
Reynolds, C .
AMERICAN JOURNAL OF SURGICAL PATHOLOGY, 1999, 23 (03) :316-322
[2]  
BAKER JR, 1970, PRINCIPLES BIOL MICR
[3]  
BAKER JR, 1963, CYTOLOGICAL TECHNIQU
[4]  
Bancroft JD., 2002, THEORY PRACTICE HIST
[5]   CONTROLLED-HEAT FIXATION OF SMEARS AND THIN TISSUE SLICES IN LIQUID MERCURY [J].
BARNETT, CH ;
CUSICK, ET ;
STOCKWELL, RA .
STAIN TECHNOLOGY, 1966, 41 (04) :239-+
[6]  
Bassarova AV, 1998, FOLIA HISTOCHEM CYTO, V36, P127
[7]   MICROWAVE IRRADIATION AS A GENERATOR OF HEAT FOR HISTOLOGICAL FIXATION [J].
BERNARD, GR .
STAIN TECHNOLOGY, 1974, 49 (04) :215-224
[8]   MICROWAVE-STIMULATED DIFFUSION FOR FAST PROCESSING OF TISSUE - REDUCED DEHYDRATING, CLEARING, AND IMPREGNATING TIMES [J].
BOON, ME ;
KOK, LP ;
OUWERKERKNOORDAM, E .
HISTOPATHOLOGY, 1986, 10 (03) :303-309
[9]   FORMALDEHYDE FIXATION AND MICROWAVE IRRADIATION [J].
BOON, ME ;
GERRITS, PO ;
MOORLAG, HE ;
NIEUWENHUIS, P ;
KOK, LP .
HISTOCHEMICAL JOURNAL, 1988, 20 (6-7) :313-322
[10]  
BOON ME, 1986, ROUTINE CYTOLOGICAL