摘要
Nearly all analyses by capillary electrophoresis (CE) are performed using optical detection, utilizing either absorbance or (laser-induced) fluorescence. Though adequate for many analytical problems, in a large number of cases, e.g., involving non-UV-absorbing compounds, these optical detection methods fall short. Indirect optical detection can then still provide an acceptable means of detection, however, with a strongly reduced sensitivity. During the past few years, contactless conductivity detection (CCD) has been presented as a valuable extension to optical detection techniques. It has been demonstrated that with CCD detection limits comparable, or even superior, to (indirect) optical detection can be obtained. Additionally, construction of the CCD around the CE capillary is straightforward and robust operation is easily obtained. Unfortunately, in the literature a large variety of designs and operating conditions for CCD were described. In this contribution, several important parameters of CCD are identified and their influence on, e.g., detectability and peak shape is described. An optimized setup based on a well-defined detection cell with three detection electrodes is presented. Additionally, simple and commercially available read-out electronics are described. The performance of the CCD-CE system was demonstrated for the analysis of peptides. Detection limits at the mum level were obtained in combination with good peak shapes and an overall good performance and stability.
引用
收藏
页码:2888 / 2893
页数:6
相关论文
共 50 条
  • [1] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Schnell, E
    Volgger, D
    Bonn, GK
    ANALYTICAL CHEMISTRY, 1998, 70 (03) : 563 - 567
  • [2] Contactless conductivity detection for capillary electrophoresis
    Zemann, AJ
    Mayrhofer, K
    Schnell, E
    Bonn, GK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1998, 216 : U162 - U162
  • [3] Contactless conductivity detection in capillary zone electrophoresis
    Kaniansky, D
    Zelenská, V
    Masár, M
    Iványi, F
    Gazdíková, S
    JOURNAL OF CHROMATOGRAPHY A, 1999, 844 (1-2) : 349 - 359
  • [4] Contactless conductivity detection in capillary electrophoresis:: A review
    Kubán, P
    Hauser, PC
    ELECTROANALYSIS, 2004, 16 (24) : 2009 - 2021
  • [5] Capacitively Coupled Contactless Conductivity Detection in Capillary Electrophoresis
    Tan Feng
    Guan Yafeng
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2005, 23 (02) : 152 - 157
  • [6] Separation of enantiomers in capillary electrophoresis with contactless conductivity detection
    Gong, XY
    Kubán, P
    Tanyanyiwa, J
    Hauser, PC
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1082 (02) : 230 - 234
  • [7] Capacitively coupled contactless conductivity detection in capillary electrophoresis
    Zemann, AJ
    ELECTROPHORESIS, 2003, 24 (12-13) : 2125 - 2137
  • [8] A Spectroscopy Solution for Contactless Conductivity Detection in Capillary Electrophoresis
    Drevinskas, Tomas
    Maruska, Audrius
    Ihara, Hirotaka
    Takafuji, Makoto
    Jonusauskas, Linas
    Armonavicius, Domantas
    Stankevicius, Mantas
    Bimbiraite-Surviliene, Kristina
    Skrzydlewska, Elzbieta
    Ragazinskiene, Ona
    Kuwahara, Yutaka
    Nagaoka, Shoji
    Kaskoniene, Vilma
    Kubiliene, Loreta
    MICROMACHINES, 2024, 15 (12)
  • [9] Determination of Silicate by Capillary Electrophoresis with Contactless Conductivity Detection
    Li Er-Ting
    Yang Li-Rong
    Huang Wen-Hui
    Wang Xin
    Xie Tian-Yao
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (04) : 568 - 571
  • [10] Design of Detection Electrode on Contactless Conductivity Detection in Capillary Electrophoresis Microchip
    Zhang, Haifeng
    Liu, Xiaowei
    Zhang, Xiaoshu
    Weng, Rui
    2013 8TH ANNUAL IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS (IEEE NEMS 2013), 2013, : 1104 - 1107